MOORE'S PHARMACY INC
200 S Rachal St, Sinton, Texas, United States
FEI 3011761505
FDA has one inspection on file for MOORE'S PHARMACY INC in Sinton, Texas (FEI 3011761505). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Sep 23, 2016 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2016
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Facility pest and structural issues
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds, insects, and other vermin. Specifically, A large dead cockroach was observed inside of your drug production room approximately 6 feet from where your firm produces capsules. Both live and dead pests were observed in your firm's pharmacy in the area where capsules are stored and counted into prescription bottles. I observed a 1 foot by 1 foot hole cut in the roof of your drug production room, exposing insulation and an uncontrolled warehouse above. No controls are in place to prevent foreign material or pests from entering the room through this hole. Doors on your firm's production room do not prevent pests from entering the room, the main door used to enter and exit the room has a 1 inch gap under the length of the door. The rear door adjacent to where capsules are produced has a [illegible] inch gap under the length of the door; this door leads to the warehouse space where people eat, use the bathroom and cardboard boxes are stored near the loading dock.
- Observation 2
Lack of potency testing before release
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release. Specifically, • Your firm failed to conduct potency testing of non-sterile finished products. From 5/24/2016 to 8/25/2016, your firm manufactured and dispensed about [illegible] prescriptions of drug products. Your firm routinely places Beyond Use Date (BUD) of drug products at 180 days. The drug products were not routinely tested for potency to ascertain the stability throughout the Beyond Use Date. • From 7/25/2015 to 7/13/2016, your firm sent no finished products produced to your contract laboratory for testing.
Show observations 3 to 5
- Observation 3
Inadequate in-process mixing controls
The in-process control procedures were deficient in that they did not include an examination of the adequacy of mixing to assure uniformity and homogeneity. Specifically, Your firm has not established procedures, policies, controls, tests or examinations which assure that batches of progesterone containing capsules are produced to assure uniformity and homogeneity. Additionally, there is not a clear indication of how pharmacists are able to check formula worksheets to determine that produced drugs were mixed correctly assuring uniformity and homogeneity. For example Tri-Est progesterone lot 2015-02-23@3 was checked and released prior to analysis by your contract laboratory. Three analysis of this lot's Estradiol potency were performed, resulting capsules returned 120.8%, 82.4% and 87.6% of expected levels. Your firm's Pharmacist in Charge stated that the firm's policy is to [illegible]. Finished product testing at your firm's contract laboratory, from 12/17/2014 to 8/26/2016, shows only lots of finished products had been tested.
- Observation 4
Missing/ignored production process procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, • There is no written process for addition, mixing and verification of chemicals on formula worksheets used by the firm to assure that manufactured drugs have the correct potency. For example, on 8/25/2016 one of your firm's pharmacists checked an [illegible] Bi-Est product 0.625/50 mg/10 mg AV Capsules, lot number 2016-08-25@2. During review, [illegible] released the lot without ensuring that the batch was made to specifications including the order of addition of chemicals and controls designed to ensure appropriate mixing. The instructions on the formula worksheet describe a different process and equipment from what I observed during the production of progesterone containing capsules. I asked the Pharmacy Tech responsible for production of this lot why they didn't use the instructions provided on the formula worksheet. He stated that the firm had [illegible]. Formula worksheets for progesterone capsule production differ from actual production or do not include the order of mixing, duration of mixing, and equipment used for mixing. Written procedures for process controls designed to assure that manufactured drugs have the correct potency are not followed. 1) Your firm's SOPs for Patient Satisfaction SOP #5.020 and Complaint Handling SOP #5.030 were authorized, reviewed and signed off by your firm's Pharmacist in Charge. They detail the process for handling complaints related to drugs produced onsite. For example, your firm provided a [illegible] with the drug, lidocaine/tetracaine/prilocaine gel lot #2016-08-17@8 for use in their practice. The [illegible] returned the lot to you with a complaint of the flavor being overly strong. After receiving this complaint your firm did not follow SOPs to document or investigate if there was a problem with the batch which could have caused it to fail to meet its specifications. 2) Your firm's SOP for Corrective and Preventative Action (CAPA) Management SOP #7.030 was authorized, reviewed and signed off by your firm's Pharmacist in Charge. It details a process control designed to assure that root problems are identified, investigated and corrected. In the last 21 months 70% of the finished products tested by your firm's contract laboratory failed to meet their potency specification. I inquired if a CAPA had been opened relating to these failures. According to your firm's Pharmacist in Charge, there have been no CAPAs and your firm does not currently follow this procedure. 3) Your firm's SOP for Recall of Compounded Product SOP #7.080 was authorized, reviewed and signed off by your firm's Pharmacist in Charge. This SOP states that 'In the event that a compounded product is suspected or confirmed to have caused patient harm, was compounded incorrectly, or needs to be recalled for any other reason, all facilities and/or patients that received the product must be notified immediately.' It also lists 'Test results from third party laboratory'. Your firm's contract laboratory notified you that 13 lots, or 70.0% of what was provided to them, failed to meet their potency specification. Your firm's Pharmacist in Charge stated that the firm at this location has not performed a recall as per SOP 7.080; furthermore she was not able to provide documentation that those patients with sub or super potent drugs had been notified of the issues with their medications. 4) Your firm's SOP for Non-Sterile Compounding Process Validation SOP #7.100 was authorized, reviewed and signed off by your firm's Pharmacist in Charge. It lists that 'All deviations must be documented.' for a formula worksheet to meet acceptance criteria. According to your firm's Pharmacy Tech, since February 2016 your firm has regularly not documented process deviations related to the mixing of drug products, including progester
Shortened here; the PDF has the full text.
- Observation 5
Use of expired materials and undocumented deviations
Deviations from written production and process control procedures are not recorded and justified. Specifically, during a review of your firm's batch records I observed that expired raw materials and drug substances were being used to produce drugs with Beyond Use Dates (BUD) of 180 days as well as other deviations from the batch record without documentation. For example: 12/11/2016 • According to the manufacturer's COA, Estriol [illegible] lot [illegible] expired on 11/07/2015. On 12/11/2016, it was used in the production of Bi-Estrogen [illegible] lot number [illegible] which subsequently failed by testing. This formula worksheet was checked by one of your firm's pharmacists, where initials appear over the top of the expiration date over a month prior to the date of the check. The expired raw material was not discarded after this batch; it continued to be used in a total of [illegible] lots after it had been expired. No deviations were noted on formula worksheets reviewed. Beyond use dates for products set by the firm are reportedly no more than 6 months or the date of the expiration of the active ingredient. Between 5/08/2015 and 3/07/2016, approximately [illegible] lots of drug products were given 180 day BUDs, which exceeded the expiration date of Estriol [illegible] lot [illegible]. No deviations were noted on formula worksheets reviewed. According to the manufacturer's COA, Prilocaine [illegible] lot number [illegible] expiration date 11/19/2016 was used to produce Priloffetra HCL/Lido lot 2016-08-17@8 BUD of 2/13/2017 for a [illegible] to use in their office. This product was returned for a complaint of overly [illegible] flavor and Prilo/Tetra HCL/Lido lot 2016-08-19@5 BUD of 2/15/2017 was produced. On the formula worksheet for the lots above, your firm's pharmacist initialed and released the lots regardless of the BUD extending beyond the expiration dates of the Prilocaine. No deviations were noted on formula worksheets. Additionally, Prilo/Tetra HCL/Lido lot 2016-08-12@5's formula worksheet calculates that [illegible] should be [illegible]. Your firm's Pharmacy Tech recorded that [illegible] and initials of your firm's pharmacist next to the number indicate that [illegible] were checked and that the [illegible] were correct. No deviations were noted on formula worksheets.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011761505 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011761505. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.