Sentara Infusion Services
535 Independence Pkwy Ste 300, Chesapeake, Virginia, United States
FEI 3011627411
FDA has 3 inspections on file for Sentara Infusion Services in Chesapeake, Virginia (FEI 3011627411), from 2015 to 2022. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 8 citations from this inspection. They are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2015–2022
- 2 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 3
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Disinfecting and cleaning agents, ISO 5 area
Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.
- FDCA 501(a)(2)(A)
Personnel contact outside ISO 5 area
Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves.
- FDCA 501(a)(2)(A)
Disinfecting materials, aseptic processing area
Materials or supplies were not disinfected prior to entering the aseptic processing areas.
- FDCA 501(a)(2)(A)
Exposure of personnel in aspectic processing
Personnel engaged in aseptic processing were observed with exposed wrists and exposed hair.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean and visibly dirty equipment or surface.
Show 3 more citations
- FDCA 501(a)(2)(A)
Actionable microbial contamination, adjacent area
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in an area adjacent to the ISO 5 classified aseptic processing area during aseptic production.
- FDCA 501(a)(2)(A)
First pass air blockage, open unit with sterile product
Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.
- FDCA 501(a)(2)(A)
Beta-lactam drugs, inadequate sanitation
You produced beta-lactam drugs without providing adequate cleaning of work surfaces to prevent cross-contamination.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic technique
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, On 07/13/2015, the following aseptic techniques were observed in the cleanroom: A) An operator was observed placing tube tips (used for puncturing vials and bags containing sterile material) on the bench top inside a Biological Safety Cabinet (BSC) before it was disinfected during a set-up for sterile drug production. B) A gowned operator was observed leaving the BSC/hood in the middle of an operation (filling of sterile drug product into elastomeric infusion devices) to grab supplies from the gowning area (outside the Cleanroom). When she returned she continued with the operation without disinfecting her gloves. There is no procedure in place that prevents operators from exiting the cleanroom area to grab supplies from non-classified areas (gowning room and hall way) fully gowned. C) An operator was observed placing a syringe (used for transferring diluents or drugs from vials to multiple elastomeric infusion device, aka home-pump) on the bench top inside the BSC; the syringe is not disinfected in between filling or transferring diluents or drugs into other elastomeric infusion devices. D) Multiple operators were observed introducing material (i.e. diluents or components) to be used for sterile drug manufacturing, into the BSC/hood without disinfecting the outside cover.
- Observation 2
Insufficient sterilization validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, A) Sterile drug products produced from non-sterile components are sterile filtered through a 0.2 micron filter. However, the firm does not perform any filter integrity testing after producing drug products purported to be sterile. Currently, products such as Hydromorphone, Morphine, Fentanyl, Bupivacaine and Clonidine are sterile filtered for intrathecal administration. B) Currently media-fill studies are conducted to monitor operators' aseptic technique. However, no media-fill study was conducted to simulate the production of sterile drug products produced from non-sterile components. Examples of these sterile drug products include Hydromorphone, Morphine, Fentanyl, Bupivacaine and Clonidine.
Show observations 3 to 11
- Observation 3
Inappropriate sterile garbing
Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform. Specifically, During the inspection of your firm, the operators we observed performing aseptic operations in the ISO 5 hoods were wearing non-sterile gowns. Specifically, the laboratory coat, face mask and pants are not sterile. Additionally, the face mask does not fully cover operator's face.
- Observation 4
Contaminated/rusty BSCs and hoods
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition. Specifically, Biological Safety Cabinets (BSC)/Hoods #2 & #4, which are ISO 5, are located in a clean room classified as ISO 7. BSC #2 is used for Total Parenteral Nutrition (TPN) bag production only and BSC #4 is used for producing products such as Meropenem (10 mL syringe) and large volume parenterals such as Vancomycin HCl and Daptomycin. The following deficiencies were observed in the above listed BSCs/Hoods: A) Stained ceiling near the entrance of the gowning area to the clean room. Various types of materials such as vitamins and sterile water are kept under this ceiling. B) Rusted vents were observed on Hood #2 (used for preparing TPNs). C) Rust was observed in the HEPA filter grills inside Hood #2. D) A black substance was observed above the HEPA filter grills (Hood #2). E) Minor rusting was observed on the HEPA grills inside Hood #4. F) Rust and foreign black substance was observed above the HEPA filters inside Hood #4. G) Stains on the inside roof and exposed light bulb were observed inside Hood #4. H) Rust and chipped paint was observed on the vents of Hood #4.
- Observation 5
Inadequate environmental monitoring
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A) Personnel monitoring is conducted on a monthly basis, whereby only the finger-tips of the operators are monitored. Environmental sampling is conducted for bench tops (BSCs), counters, and sinks on a monthly basis. The sampling medium ("paddle") used for finger-tips and surface sampling is currently not tested for growth promotion. The "Paddle" is also used for air sampling (passive) in the BSC on a monthly basis. B) No settle plates, active air and non-viable air is monitored in the BSC during aseptic operations.
- Observation 6
Unvalidated cleaning/disinfectant procedures
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A) The following disinfectants are used for sanitizing the BSCs and the surrounding areas: 70% IPA, "Peridox RTU" (label claims it's fungicidal, sporicidal and virucidal), "Accel TB" (label claims it's bactericidal & virucidal), and pre-soaked wipes "Prostat Sterile". No efficacy study was performed to determine if these disinfectants are capable of reducing the microbial load to an acceptable levels in the BSCs and other surfaces (i.e. benchtops, walls and floor) in the cleanroom (ISO 7) where aseptic operations take place. B) Cleaning procedure, P-304.2 entitled "CLEANING AND DISINFECTING OF THE COMPOUNDING AREA" does not clearly indicate the type of disinfectants to be used. Specifically, there is no mention of the various disinfecting agents used in the ISO 5 (BSC/Hood) area currently. Additionally, 70% IPA and the sporicidal disinfectant ("Peridox RTU") are not being used in the cleanroom or the Hoods in alternating fashion.
- Observation 7
Incomplete BSC qualification
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, The last qualification of the Biological Safety Cabinets/ISO 5 Hood was conducted in June, 2015 and it did not challenge all the BSCs during the smoke study under dynamic conditions.
- Observation 8
Missing sterility/endotoxin testing
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, No sterility and endotoxin testing has been conducted for sterile drug products produced from non-sterile components since November, 2014. Additionally, TPNs are tested for sterility on a weekly basis and other sterile drug products are tested periodically (up to every 6 months) for sterility. The sterility samples (on a TSB Medium) for the TPNs were incubated at a temperature ranging from 33-35°C for 14 days. However, the direction for the sampling unit, Quick Test™ System, instructs the user to incubate at 20 to 25°C. Furthermore, the firm did not evaluate the sterility samples using media intended to support anaerobic microbes.
- Observation 9
Lack of stability/expiration data
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, No stability or potency testing has been conducted for sterile drug products produced from non-sterile components since November, 2014. Examples of non-sterile powders include Hydromorphone, Morphine, Fentanyl, Bupivacaine and Clonidine.
- Observation 10
Uninvestigated positive environmental findings
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, The environmental monitoring records from 05-01/2014 to 05/30/2015 contain positive results that were obtained for personnel's finger-tips. No investigation was conducted to determine the source of the contamination and impact on product quality and safety. Furthermore, the microbes were not quantified and identified, and no alert or action limit is established for environmental monitoring. The observed growth was for the following "finger-tip testing": • Testing date 05/09/2014: Left-hand • Testing date 05/16/2014: Left-hand • Testing date 05/27/2014: Left-hand and second operator had growth on his right-hand • Testing date 05/30/2014: Left-hand • Testing date 11/26/2014: Left-hand • Testing date 05/28/2015: Left-hand Additionally, no trending is performed for monitoring environmental conditions.
- Observation 11
Missing equipment calibration records
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed. Specifically, There are no calibration and qualification records for incubator, Boekal Industries, Model I 33000. This incubator is used for incubating environmental samples from the cleanroom and ISO 5 Hoods, and for TPN sterility samples.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011627411 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011627411. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.