Skip to content

MSN Life Sciences Private Limited

Sy.No. Parts of 454, 455, 457, 458 & 459, Chandampet (Village), Shankarampet (Mandal), Medak, India

FEI 3011543392DUNS 650810141

Company: MSN Life Sciences Private Limited · Linked by exact D-U-N-S match (650401578) in FDA registration data

FDA has 2 inspections on file for MSN Life Sciences Private Limited in Medak, India (FEI 3011543392), from 2017 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant, MSN Life Sciences Private Limited (D-U-N-S 650401578), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2017–2024
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
3 requests, latest Jun 24, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate OOS investigations

      Your firm failed to thoroughly investigate critical deviations and/or the failure(s) of a batch to meet specifications. Specifically, A1. Out-of-Specification (OOS)-23064 Investigation was inadequately completed to justify the invalidation of the initial OOS result for Assay by HPLC (Preparation-2) for: [illegible] Lot [illegible] for stability testing (long term 36 months). A2. During the investigation for OOS-23064, an analyst was identified to conduct a remeasurement of the sample solutions to determine a probable root cause for OOS-23064. However, per the investigation report (07-OOS23064-R-01), the analyst inadvertently utilized a different sample solution to complete the re-vial testing. Even though the investigation acknowledges the human error, the investigation does not appear to include a new re-vial testing conducted for the true sample solution utilized in the original OOS, and the human error for the re-vial test was not identified and investigated as a separate quality-related event such as a Deviation. B1. OOS-24006 Investigation was inadequately completed to justify the invalidation of the initial OOS result for Assay by HPLC (Preparation-1) for [illegible] Lot [illegible] for stability testing (long term 24 month). B2. During the investigation for OOS-24006, there was a system suitability failure during the remeasurement testing (re-injection; re-vial; and re-dilution) analysis. Even though the system suitability failure was documented in the investigation, the investigation did not conduct a new remeasurement analysis to determine a root cause and support a re-analysis of the stability sample. Additionally, the quality unit failed to separately investigate the system suitability failure under a Laboratory Incident Form per the firm's SOP CQC-0052-000 titled "GOOD LABORATORY PRACTICES" with an effective date of 01/03/2022 (March 1st, 2022). C. There were a pattern of OOS Investigations where the quality unit failed to initiate and complete a separate investigation (Laboratory Incident Form) for each suitability failure identified during each investigation including the one specified under B2: - OOS-24032 -- Missing at least one (1) laboratory incident form - OOS-23093 -- Missing at least two (2) laboratory incident forms

    2. Observation 2

      Quality unit failed comprehensive review

      Your quality unit failed to review all critical deviations or non-conformances and related investigations for all API products. Specifically, There were quality-related events (OOS, deviations, system suitability failures [invalid and incident]) that were not separately identified for the purposes of review and/or trending purposes to identify quality-related deficiencies. Multiple quality-related events were identified within one (1) quality event investigation which can dilute the total number of quality-related events to review within a given time period.

    Show observations 3 to 4
    1. Observation 3

      Failure to handle out-of-trend results

      Your quality unit failed to perform one of it's core responsibilities to ensure that critical deviations are investigated and resolved. Specifically, Out-of-Trend (OOT) ranges were not calculated and evaluated for a number of specification tests for some of your API products that were: 1) manufactured with less than [illegible] batches and 2) were not updated within the firm's recently implemented LIMS system. According to your firm's SOP CQC-0003-002 titled "HANDLING OUT-OF-TREND RESULTS" with an effective date of 05/06/2023 (June 5th 2023), section [illegible] describes a way for handling OOT during API release testing for APIs without trend limits calculated from the [illegible] batches.

    2. Observation 4

      Inadequate hand-washing facilities

      Your production areas fail to provide adequate washing facilities for personnel. Specifically, The washing area(s) prior to entry into the cleanroom area(s) of production did not have access to hot water for hand washing.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Jun 24, 2026. Each one asked for a Form 483.

  • Inspection ending Sep 13, 2024VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jun 24, 2026FDA-FOIA-2026-6047Form 483· 1 of 2 sitesRecords released
    2. May 15, 2026FDA-FOIA-2026-4982Form 483Records released
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Jan 25, 2021FDA-FOIA-2021-501Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, analysis
Registration runs through
Dec 31, 2026
Registrant
MSN Life Sciences Private LimitedD-U-N-S 650401578

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names MSN Life Sciences Private Limited (D-U-N-S 650401578) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3011543392 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3011543392. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.