Abrams Royal Pharmacy II, LLC
4909 W Park Blvd Ste 177, Plano, Texas, United States
FEI 3011286375
FDA has one inspection on file for Abrams Royal Pharmacy II, LLC in Plano, Texas (FEI 3011286375). It ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Aug 26, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2015
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
No potency testing before release
Your firm has not established appropriate testing and release procedures and controls to ensure finished drug products conform to satisfactory identity and strength prior to release. Specifically, 1. Your firm does not conduct potency testing for any of the drug products produced by your firm. Listed are examples of drug products your firm produced and distributed within (b)(4) without potency testing: a. Testosterone-Q Pump 75 mg/mL Cream, Lot 04242015 @35, Distributed 4/24/2015 b. Estradiol-U Pump 15 mg/mL Cream, Lot 04232015 @5, Distributed 4/23/2015 c. Piroxicam 3 mg Capsule, Lot 04172015 @34, Distributed 4/17/2015 d. Cortisol-MC 10 mg Capsule, Lot 04012015 @45, Distributed 4/30/2015 e. Liothyronine (T3)-MC 375 mcg Capsule, Lot 04062015 @48, Distributed 4/6/2015 2. Your firm does not conduct testing to assure product uniformity and homogeneity.
- Observation 2
Unjustified beyond-use dates (BUDs)
Your firm has not established procedures and controls to ensure finished drug product's Beyond Use Dates (BUD) are appropriate. Specifically, your firm does not have a written stability testing program to determine BUDs placed on all your drug products. For example, 1. Your firm does not have documentation to justify the following BUDs placed on the drug products (b)(4) produced by your firm. They include, but are not limited to: a. Cortisol-MC 5 mg Capsule, Lot 04102015 @6, BUD 180 Days b. Cortisol-MC 10 mg Capsule, Lot 04012015 @45, BUD 180 Days c. Cortisol-MC 15 mg Capsule, Lot 12222014 @24, BUD 180 Days d. Cortisol-MC 20 mg Capsule, Lot 03242015 @48, BUD 180 Days e. Cortisol-MC 25 mg Capsule, Lot 04132015 @13, BUD 180 Days f. Liothyronine (T3)-MC 150 mcg Capsule, Lot 03232015 @29, BUD 166 Days g. Thyroid-P (4 Grain) 240 mg Capsule, Lot 04222015 @21, BUD 166 Days h. Testosterone-Q Pump 30 mL 20 mg/mL Cream, Lot 03192015 @16, BUD 180 Days i. Progesterone RDT 50 mg Tablet, Lot 02042015 @12, BUD 180 Days
Show observation 3
- Observation 3
Improper personnel garb during compounding
Your firm has not established procedures to ensure appropriate clothing is worn by your personnel engaged in producing finished drug products. Specifically, on 4/27/2015, your firm's technician did not wear the required apparel while producing Test!Prog-Q 200/25 mg/mL P, Lot 04242015 @31, Beyond Use Date 9/23/2015, in the Lab. He did not wear a beard cover. In addition, he did not wear his face mask correctly. The mask rested under his nose instead of over it. According to SOP 9.130, "Required Garb for Non-Sterile Compounding Area", Date Effective 09-27-12, Version 1.0, Section 9.1 and 9.1.2, "Prior to non-sterile compounding activities, all personnel must: Don a clean hair net, beard cover (if necessary) and face mask".
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011286375 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011286375. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.