Skip to content

Physician Preferred Medical, LLC

3300 NW 56th St Ste 101, Oklahoma City, Oklahoma, United States

FEI 3011278953

FDA has 2 inspections on file for Physician Preferred Medical, LLC in Oklahoma City, Oklahoma (FEI 3011278953), from 2015 to 2016. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Feb 19, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
2, 2015–2016
1 OAI · 0 VAI · 1 NAI
Inspections with 483 observations shown
1 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance18 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate cleanroom areas and controls

      The separate or defined areas and control systems necessary Specifically, a) The cleanroom (buffer room) is equipped with a direct b) The ante-room, where gowning and entry into the cleanroom occurs, c) Your firm does not have any documentation of smoke studies having been performed d) During the certification of the [illegible] hood (serial number [illegible]) that the HEPA filter needed to be replaced. Your firm [illegible] 11/1/14 and 1/5/15, the hood was used during the weighing, melting, granulation, sieving, and packaging lots of granulated [illegible] of granulated estradiol; estradiol pellets (varying strengths). e) Your firm does not have a scientific rationale for performing environmental monitoring of hoods only once every [illegible] during certification of f) Your firm has not established alert and action limits for the cleanroom (buffer room). During the last certification [illegible] and 5 cfu (surface) found in the cleanroom and 9 cfu (active air) g) Your firm does not perform any personnel monitoring for pellets. h) The cleanroom (buffer room) and ante-room are not equipped resulting in a lack of monitoring of pressure differentials during operations. There [is no documentation by] your firm of the pressure differential between the cleanroom (buffer room) and the ante-room and the retail pharmacy. The last [certification] reported the ante-room is +.0290" W.C. positive to the retail pharmacy; (buffer room) is +.0025" W.C. positive to the ante-room; the cleanroom (buffer room) is +.0674" W.C. positive [illegible]. The (buffer room) does not meet the minimum pressure differential certification. i) The exhaust vent for the cleanroom (buffer room) exits [illegible]. j) Re-certification of the cleanroom (buffer room) did not come to facilitate cleaning or the addition of the [illegible].

    2. Observation 2

      No sterilization process validation

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are deficient and do not include validation of the sterilization process. Specifically, your firm has not validated the sterilization process for any of the drug products that you prepare. Your firm prepares testosterone and estradiol pellets of strengths [illegible] from bulk non-sterile API and excipients, places them into non-sterile vials with [screw top lids] and then [illegible] used.

    Show observations 3 to 18
    1. Observation 3

      Inadequate investigations of failures

      There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch to meet any of its specifications whether or not the batch has been already distributed. Specifically, a) Lot #06241401-070714Q of Estradiol 18 mg pellets made [illegible] 7/17/14 & 7/8/14 and was recalled by your firm on 7/24/14. There is no documentation by your firm into the sterility failure and no corrective actions implemented. b) The last environmental monitoring of your cleanroom (buffer room) by a third party in October 2014 revealed levels of microbiological contamination in your cleanroom (buffer room) that were considered above action level per the report. The report states that viable environmental sampling "requires attention." Counts in the cleanroom (buffer room) were 25 CFU for active air. The report states counts in the ante-room were 7 CFU (surface). There is no documentation of an investigation performed by your firm into this failure and how this may impact product. Your Pharmacist stated that after the report you changed the disinfectant used from [illegible] and no additional environmental monitoring was performed after the change in disinfectant to demonstrate that the corrective action was effective. c) The last certification report for the hoods in [illegible] failed air flow testing. The report states that the "device does not meet the minimum velocity. Filter needs to be replaced ASAP." Your firm failed to replace the HEPA filter until 1/6/15. There is no documentation of an investigation by your firm into the failure of the filter or any product impact. From the date of the initial failure in October 2014 until it was changed on 1/6/15, lots of testosterone pellets (varying strengths) and lots of estradiol pellets (varying strengths) were produced.

    2. Observation 4

      No validated cleaning procedures

      Written procedures are not established for the cleaning and maintenance of equipment used in the manufacture, processing, packing or holding of a drug product. Specifically, a) Your firm has not validated the cleaning/disinfection procedures for equipment used to make testosterone and estradiol pellets. b) Your firm is using non-sterile wipes when cleaning and disinfecting the equipment used to prepare testosterone and estradiol. The non-sterile wipes are used on all equipment used [illegible] c) [illegible] d) Your firm is not documenting [illegible] equipment [illegible] that operations occur.

    3. Observation 5

      Insufficient sanitation procedures and records

      There is a lack of written procedures assigning responsibility, providing cleaning schedules, and describing in sufficient detail the methods, equipment and materials to be used for sanitation. Specifically, a) Your firm has not validated the cleaning/disinfection [illegible] and estradiol pellets are made. b) Your firm is using non-sterile wipes when cleaning [illegible]; non-sterile wipes are used on the floors, walls and ceilings of the cleanroom and the powder hoods. c) Your firm is using non-sterile [illegible] and [illegible] to clean the [illegible] hoods. d) Your firm is not documenting the preparation of or the specific cleaning agents and disinfectants used in the cleanroom (buffer room) [illegible] that operations occur.

    4. Observation 6

      Inadequate personnel gowning

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform. Specifically, the general gowning attire for entry into the cleanroom (buffer room) where testosterone and estradiol pellets are made consist of the following: scrubs worn from outside the facility, a disposable labcoat, a single hair net, mask with ties and booties. All are non-sterile. The operators use non-sterile gloves. The general gowning requirements leave exposed skin around the eyes, forehead, and neck of the person preparing the drug product. Your firm does not have a scientific rationale for [illegible].

    5. Observation 7

      Inadequate container-closure suitability

      Container closure systems do not provide adequate protection against foreseeable external factors that can cause deterioration or contamination of the drug product. Specifically, your firm packages the testosterone and estradiol pellets into non-sterile/non-depyrogenated 2 mL amber glass vials with a screw top lid. Your firm has no documentation to show that this packaging and container/closure system is suitable to protect the drug product from external factors that may affect the quality and sterility of the drug product over time.

    6. Observation 8

      Containers not sterilized or depyrogenated

      Drug product containers and closures were not sterilized and processed to remove pyrogenic properties and are not suitable for their intended use. Specifically, your firm packages the testosterone and estradiol pellets into non-sterile/non-depyrogenated 2 mL amber glass vials with a screw top lid that are [illegible]. Your firm does not remove pyrogenic properties. Your firm has not validated [illegible] to show that the vials and [illegible].

    7. Observation 9

      Facility not designed for cleaning/maintenance

      Buildings used in the manufacture, processing, packing, or holding of a drug product are not of appropriate design to facilitate cleaning, maintenance, and proper operations. Specifically, a) The floor of the cleanroom (buffer room) is constructed [illegible]. b) The ceiling of the cleanroom (buffer room) is constructed [illegible]. There is a noticeable lip between the [illegible] circumference of [illegible] allowing open access directly into the cleanroom (buffer room) from the adjoining unclassified areas above and about.

    8. Observation 10

      Incomplete laboratory specifications

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, your firm has not defined all specifications for the release of each lot of drug products prepared by your firm. Your firm has not determined endotoxin limits for your pellet products (testosterone and estradiol), drug release rate, or any other specifications of the active ingredient that affect the quality of the lots.

    9. Observation 11

      Insufficient product testing before release

      Testing and release of drug product for distribution do not include appropriate laboratory determination of conformance to the final specifications and identity and strength. Specifically, your firm does not conduct potency testing for all lots [illegible].

    10. Observation 12

      No stability program; inappropriate BUDs

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, your firm does not have a written stability testing program to justify the Beyond Use Date (BUD) placed on your testosterone and estradiol pellets. In addition, the BUD assigned to some lots exceeds the expiration date/retest date of the active pharmaceutical ingredient (API) used. For example, the expiration date of Testosterone USP per the Certificate of Analysis from your vendor is 2/28/15. This lot of API was used in lot #11251401 of Testosterone. Lot #11251401 was in turn used to make lots #120114P (100 mg) and others. The BUD to these lots was 05/15. This BUD of 180 days for pellets exceeds the expiration/retest date of the API used.

    11. Observation 13

      No endotoxin testing for batches

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, your firm does not perform endotoxin testing on a new lot of granulation.

    12. Observation 14

      Deficient master production records

      The master production and control records are deficient. Specifically, your firm does not include in the batch records for the testosterone and estradiol pellets the sterilization [method] to be used or the date of sterilization. A few weeks (date unknown) your firm purchased a new [illegible] capability to sterilize any [illegible] of testosterone pellets (varying strengths) and [illegible] lots of [illegible] documentation of the sterilization of the lot.

    13. Observation 15

      Procedures yield <100% active ingredient

      Written production and control procedures include batches formulated with the intent to provide less than 100 percent of the labeled or established amount of active ingredient. Specifically, the production records for testosterone and estradiol pellets do not provide for 100% of the labeled or established amount of active.

    14. Observation 16

      Inadequate calibration of balances

      Routine calibration and checking of electronic equipment is not performed to assure proper performance. Specifically, a) The most recent electronic balance certification last performed on 8/8/14 did not include specific balance identifications and the certification stickers were placed on a sheet of paper instead. b) Electronic balances [illegible] used to weigh the active pharmaceutical [ingredients for testosterone and estradiol]; the balances are not calibrated within their range and your firm uses them as a "counter scale over 10 lbs" and the actual [illegible]. c) The electronic balances (models [illegible]) and the finished product pellets are not [illegible] following from the storage table to the [illegible] a batch of pellets is made.

    15. Observation 17

      No yield limits or investigations

      Master production and control records lack a statement defining the minimum and maximum percentages of theoretical yield beyond which investigation is required. Specifically, batch records for the testosterone and estradiol pellets do not define a minimum and maximum percentage of theoretical yield beyond which an investigation is required. A review of lots from November 1, 2014 - January 31, 2015 showed some actual yields for estradiol pellets to be [illegible]. Examples include: a) 6 mg: (lot 12161401-0108158) and [illegible] (lot 01131501-011515F), b) 10 mg: [illegible] (lot 10271402-1121140), c) [illegible] (lot 10271401-1110141), d) 15 mg: (10271401-1027140) and [illegible] (lot 10271402-121014T), e) 20 mg: [illegible] (lot 12161401-121714V), f) 22 mg: [illegible] (lot 01131501-011415E) and lot [illegible], g) 25 mg: (lot 10271402-121514U) (lot 0[illegible]). There is no documentation that an investigation was performed for any of these lots.

    16. Observation 18

      Equipment not easily cleanable

      Equipment used in the manufacture, processing, packing and holding of drug products is not of appropriate design to facilitate its cleaning and maintenance. Specifically, the work tables used to hold the [illegible] are not easily cleanable.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011278953 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011278953. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.