Skip to content

PharmaLogic CSP, Inc.

9 W Benedum Industrial Dr, Bridgeport, West Virginia, United States

FEI 3011193301

FDA has one inspection on file for PharmaLogic CSP, Inc. in Bridgeport, West Virginia (FEI 3011193301). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Jul 23, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2014
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Cleaning/disinfection deficiencies

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a) (b) (4), is used to make the disinfectants, (b) (4) The disinfectants are used to clean the ISO7 "Manufacturing Room" and ISO 8 "Anteroom". No sporicidal agents are used to clean either of these rooms. b) [illegible] ISO5 Laminar Air Flow Hoods, which are used to produce sterile drugs, and the [illegible] which are used to bring supplies into the ISO 7 Cleanroom, are only cleaned using sterile [illegible]. No disinfectants or sporicidal agents are used in cleaning. c) A [illegible] is used to clean the floors, walls, and ceilings in the ISO 7 Cleanroom and ISO 8 Anteroom with non-[illegible]. The [illegible] is stored in an unclassified area between cleanings for up to a week. d) Buckets used to [illegible] from an unclassified common area into the ISO 7 Cleanroom are not wiped or sanitized after contacting multiple non-sterile surfaces including the inside of a sink, the floor of the unclassified common area, and the floor of the ISO 8 Anteroom.

    2. Observation 2

      Environmental monitoring procedure missing

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, there is no written procedure describing the requirements for environmental monitoring in aseptic processing areas, including the frequency of sampling or the action and alert limits for personnel, surface, and air samples. In addition, personnel monitoring is not performed during routine production.

    Show observations 3 to 8
    1. Observation 3

      Pressure differential monitoring lacking

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, there is no documentation showing that pressure gauges are reviewed during production of sterile drugs to demonstrate that appropriate pressure differentials are maintained between classified areas. The pressure differentials are not alarmed or continuously monitored by an electronic system. Production System

    2. Observation 5

      Stability studies not completed

      Results of stability testing are not used in determining expiration dates. Specifically, stability studies have not been completed to support the ninety (90) day expiry period on the following released lots of sterile drug products: Fentanyl 10mcg/mL Lot# 11181401, 11181402, 11181403, 11181404, [illegible], 11241401, and 11251401; and Calcium Gluconate 2g in 100mL Lot# 1J171401, 11171402, 12031402, 12091401, and 12091402. The studies were initiated in September 2014 for Fentanyl and October 2014 for Calcium Gluconate.

    3. Observation 6

      Containers/closures not QA-released

      Each lot of drug product containers and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit. Specifically, Certificate of Analysis reports are not received for each lot of sterile containers and closures, which are used for finished sterile drug products.

    4. Observation 7

      Required labeling statements missing

      The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, the labels for midazolam 1 mg/ml, morphine 1 mg/ml, and Pitocin 20 units do not have the statement "This is a compounded drug". Also, none of the labels have the statement "Office Use Only" or the date the drug was compounded.

    5. Observation 8

      Required administration information missing

      The container of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(B). Specifically, the labels for Levophed 4 mg, Calcium Gluconate 2 g, Morphine 1 mg/ml, Pitocin 20 units, Succinylcholine 20 mg/ml, Ketamine 10 mg/ml, and Rocuronium 10 mg/ml do not contain administration information.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011193301 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011193301. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.