Sichuan Deebio Pharmaceutical Co., Ltd.
15 Gaocaocun, Xiaohanzhen Guanghan, Deyang, China
FEI 3011139911
FDA has one inspection on file for Sichuan Deebio Pharmaceutical Co., Ltd. in Deyang, China (FEI 3011139911). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2023
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Laboratory records and data integrity
Laboratory records are not completed contemporaneously and do not include complete data derived from all tests to assure compliance with established specifications and standards. Specifically, A. During our visit to your QC microbiology laboratory, we observed that results for QC microbiology work bench samples from Workshop (b)(1) plates, sample points (b)(4) (production for US Market), and (b)(6) sample points (b)( ) (domestic and non US international market) purported to be read by your QC team leader per SOP no. MA0057-04, titled 'Data reliability management procedures.' Specifically, upon entering the microbiology laboratory on 09/04/2023 we observed approximately [illegible] plates in the waste bin which had been [illegible]. Your QC team leader stated that she had read these plates earlier in the morning around 10:00 am, and that the test worksheet with recorded results was downstairs with a QA personnel. Your QC team leader then proceeded to provide misleading information, stating that she did not read the results as she had stated doing so when we first arrived in the laboratory, and shortly after this stated that she did read the results and signed the test data worksheet which was somewhere on the bench with QA personnel, only to finally admit that she did in fact read the plates, however, was not certain about recording the results on respective data worksheets, and asked the analyst how she remembered the results from 'mind' and proceeded to provide at least [illegible]. Your firm's investigation was not able to replicate any of these values that your analyst provided to us in person. We left the laboratory around 1:40 pm, having initially arrived around 11:40 am. As a result of providing misleading information, your firm delayed our inspection. B. During our review of electronic data generated with SevenExcellence software on your Multiparameter analyzer (equipment ID No. J01-0310A) we observed no available printouts for QA approval. Per your firm, the electronic data had been lost due to potential inadequate data backup procedures. When we requested the related physical analytical batch records, we observed no printouts attached with the test worksheets reviewed by QC and QA for batch approval and release for batches (b)( ) which were subsequently shipped to the US Market. When performing these tests, the printer was not connected, and no such printout exists for any test performed prior to June 2022. There is no evidence of retained electronic or physical data for process validation batches, which have been shipped to the US Market. C. During my review of electronic test data for test item 'Limit of' (b)( ) your review found that when undesirable results are encountered during analysis of (b)( ) USP drug substance, the original test results for batch no. [illegible] (accelerated 2-month stability study) were both [illegible]. No laboratory investigation was initiated per your firm's OOS procedure. For example, batch no. (b)( ) was tested on 11/01/2021 and the initial result was not reported, and no OOS investigation was initiated. Shortly after on the same day, around (b)( ) pm, a second test was performed with result [illegible] and reported.
- Observation 2
QC method validation and oversight failures
The quality control unit lacks responsibility impacting on identity, strength, and purity of [illegible]. A. Your firm's test method validation for Residual Solvent test by GC for USP drug substance is inadequate. During your method validation, your firm failed to identify additional peaks observed in the sample solution chromatogram. Per your firm, after this deficiency was identified through a customer audit performed on or around 03/24/2022, your firm contracted a third-party laboratory who identified the (b)(4) impurity. As of the current inspection, your firm has not initiated an investigation with respect to this event, nor has it performed any laboratory manufacturing studies to determine the source of the additional peaks or to study the identified and unidentified impurities for the USP drug substance. B. Your firm has not performed an impurity profile study which may be present in your (b)( ) drug substance and consequently does not perform impurity testing for released drug substance. C. Supervisory oversight over the laboratory electronic systems and data is deficient. For example, there is no procedure in the QC Laboratory which describes the requirements/conditions under which the manual integration of chromatograms generated by the HPLC and GC systems can be performed.
Show observations 3 to 6
- Observation 3
Inadequate process validation controls
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug substance have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A. Process validation studies executed to assure intended drug substance quality is achieved are inadequately designed and executed. For example, process validation performed for (b)( ) drug substance fails to contain scientific justifications for the establishment of uniformity sample size and frequency, %RSD established limits, inlet pressure, blending time, and lack of in-process sampling. During the inspection of customer complaint no. TS-2023002, dated 04/13/2023, for inadequate [illegible] of released USP drug substance, your firm used process validation/commercial batch numbers (b)( ) where the customer obtained OOS results after sampling from top, middle, and bottom of drums. As stated, these batches were also used for your process validation studies. B. Your firm's practice of mixing more than (b)( ) sublots to get the (b)( ) USP drug substance has not been evaluated for its potential impact on the variation of (b)( ) assay content. During our review we observed that five (5) out of [illegible] process validation batches contained at least (b)( ) sublots blended with (b)( ) to make the finished lot. Per your firm, in most cases the finished API lot has the option to blend (b)( ). C. No studies have been performed on the effect of [illegible] parameters, with respect to microbiological and degradant control in the drug substance which considers the validated [illegible] operations.
- Observation 4
Insufficient investigation and CAPA documentation
Written records of investigation into unexplained discrepancies and the failure of a batch or its components to meet specification do not always include the conclusions and follow-up. Specifically, A. Your firm received Complaint No. TS-2023002 reporting out-of-specification levels of (b)(4) from batch (b)(4). Complaint No. TS-2023003 reported out-of-specification [illegible] for batch (b)(4). For Complaint No. TS-2023002, your firm conducted sampling with a handheld scoop at the top, middle, and bottom of remaining (b)( ) drums. Your firm's investigation did not adequately document investigation into critical pieces of information and critical manufacturing process steps. Per your firm's quality control team leader for investigation into Complaint No. TS-2023002, your firm conducted sampling with a handheld scoop at the top, middle, and bottom of remaining (b)( ) drums. Your firm's investigation was driven by perceived expediency rather than documented sampling methods used for (b)( ) testing of batch (b)( ), and did not include a formal documented investigation nor carry out corrective and preventive actions following these complaint investigations. B. Deficiencies identified within your quality unit operations by your firm based on a customer audit performed on or around 03/24/2022, including, but not limited to, loss of electronic data, unreported test results, and inadequate documentation were not adequately documented in your Quality System per your deviation, CAPA, change control, and OOS procedures. For example, with respect to electronic and paper data loss in your SevenExcellence software for Multiparameter analyzer equipment ID No. J01-0310A used for test item 'Limit of' (b)( ), your firm completed a data integrity risk assessment but no official investigation, deviation, or CAPA was initiated. Your firm does not have the ability to track, trend, and document these deficiencies.
- Observation 5
Inadequate cleaning validation and records
Written procedures are not established nor followed for cleaning and maintenance, including utensils used in the manufacturing, processing, packing, or holding of a drug product. Specifically, A. Your firm failed to develop a validated cleaning and testing method for the (b)(4) equipment S13-005 and other pieces of manufacturing equipment that confirm your firm's ability to detect and remove (b)(6) and other residual solvents on manufacturing equipment used in the production of (b)(4) USP drug substance. The firm's rationale that evaluation of (b)(4) is not supported with documented scientific justification. B. On pages 13 and 17 of our firm's cleaning [illegible] records, your firm did not adequately accomplish nor review the cleaning procedure (WP0306-03) after production of (b)(4). Additionally, your firm's deviation (Deviation C-2023309-0bc2-5) opened on 2023.09.04 for these discrepancies did not adequately document investigations into cleaning record deviations for other critical pieces of manufacturing equipment used in the manufacturing of (b)(4) USP.
- Observation 6
Inadequate shipping and temperature controls
Control procedures are not established which ensure that shipping conditions are maintained and which may be responsible for causing variability in the characteristics of the drug substance. Specifically, your firm ships (b)( ) USP drug substance to [illegible] degrees Celsius for temperature, and the shipping container and components used do not provide assurance that the drug substance in transit stays within its specified range for the duration of the shipment. There is no official validation study regarding the performance of distribution processes that ensure the drug substance remains within temperature storage specifications for (b)(4) USP drug substance.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011139911 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011139911. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.