Skip to content

Allegheny Health Network Home Infusion, LLC

311 23rd Street Ext Ste 500, Sharpsburg, Pennsylvania, United States

FEI 3011127887

FDA has one inspection on file for Allegheny Health Network Home Infusion, LLC in Sharpsburg, Pennsylvania (FEI 3011127887). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2018
Inspections with 483 observations shown
1 of 1
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Improper gowning contamination risk

      Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, On 09/20/2018, I observed an Operator donning a used disposable coverall. While donning, the legs of the coveralls contacted the floor of the Ante Room.

    2. Observation 2

      Non-sterile wipes used in ISO 5

      Disinfecting agents and cleaning pads or wipes used in the ISO 5 area [aseptic processing areas] are not sterile. Specifically, On 09/17/2018, I observed non-sterile wipes applied to surfaces within the ISO 5 area of the workbench in the non-hazard clean room, where aseptic processing of sterile products occurs. The wipes were identified as (b)(4) lint-free wipes. Products produced in the ISO 5 area workbench on 09/17/2018 include, but is not limited to the following: - Milrinone 0.8 mg/ml 165 ml, Rx Number: [illegible], Quantity: [illegible] - Methylprednisolone 1 g/100 ml, Rx Number: [illegible], Quantity: [illegible]

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011127887 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011127887. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.