Ionia Pharmacy
15421 Red Hill Ave, Tustin, California, United States
FEI 3011014614
FDA has one inspection on file for Ionia Pharmacy in Tustin, California (FEI 3011014614). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Jul 17, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2015
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. SOP No. 2004 effective 11.10.14 titled "Environmen" that a. There is no requirement to conduct personnel fingertip monitoring including forehead, when products are made. ---- On 11/21/14, fingertip count of one (1) colony. The firm "Environmental" b. Surface monitoring of ISO 5 and ISO 7 areas are performed on a daily basis when products are made. Per [the firm] not maintain records. Non-viable monitoring is performed on a per SOP 2182 section C which states [frequency determined by PIC]. The last [viable monitoring] performed on [illegible]. c. There is no requirement to use disinfectant neutralizers before taking environmental samples in the ISO 5, ISO 7 and ISO 8 zones. Per the PIC, the B. The ISO 5 hood is deficient in that a. The dynamic smoke studies conducted on the plastic protector down. We also observed that the third arm with arm skin still exposed during smoke study testing using mask, or chest on a [stool]. In actual practice, fingertip testing is [performed] during product manipulation. We observed that the technician did not have record to verify the type of colony found. According to the PIC, the ISO 5 vertical laminar flow hood which has a hood opening up to the head of the technician (or about 3/4 of the hood) when he sits down on the stool to work. If the plastic protector is placed down, the opening would open down to about chest level or below (or about 1/3 of the hood). On both 03/03/15 and 03/04/15, we observed the technician making products with the plastic protector up. i. Testosterone Cypionate 200mg/Progesterone 2.5mg per ml lot #030315F produced on 03/03/15. ii. Papaverine/Phentolamine/Alprostadil 22.5/0.83/8.33 mg per ml lot #030315CU produced on 03/04/15. b. There is no pressure differential monitoring between ISO 5 and the ISO 7 room to determine whether the vertical airflow from the ISO 5 hood is greater than the ISO 7 room.
- Observation 2
Inadequate cleaning/cleaning validation
Equipment and utensils are not cleaned at appropriate intervals and with appropriate agents to ensure the strength, quality or purity of the drug product. Specifically, A. The firm has not performed cleaning validation to show that their cleaning reagents are effective against bacteria, fungus, yeast, mold, and spores. SOP No. 2034 titled "General Aseptic Procedures for cleaning and [disinfection]" effective 11/17/14 mentions the use of an [illegible] reagent. None of the cleaning reagents used were verified as sporicidal. This SOP also mentions the use of non-shedding wipes (non-sterile wipes); the firm could not verify that the wipes are appropriate for production. There is no sanitization record for the wipes. B. On 03/03/15, we observed one package containing vials to make Testosterone Cypionate 200mg/Progesterone 2.5mg per ml lot #030315F brought into the ISO 5 hood. We observed that the package was not cleaned with an appropriate disinfectant prior to being brought from ISO 7 room into the ISO 5 hood using aseptic technique. C. The firm's SOP No. 3026 effective 09/03/12 titled "Use, Calibration, Cleaning, and Maintenance" is deficient in that it does not address how the firm cleans the [illegible] used to crimp the caps after placing the rubber stoppers onto the container.
Show observations 3 to 10
- Observation 3
Inadequate media-fill/sterility procedures
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not adequate or not followed. Specifically, On 03/05/15, we observed that the incubator used by the firm was not temperature monitored. We observed that the reading inside the incubator was [illegible] to verify the reading. This media fill process does not simulate the actual production process with respect to container closure size (actual product sizes are 5 mL, 10 mL, and 30 mL) and processing duration. According to the PIC, the media fill process takes about [illegible] to complete, however, no challenges or interventions are introduced during the media fill operations. For example, a. Testosterone Cypionate 200mg/Progesterone 2.5mg per ml; b. Testosterone Enanthate 250 mg/ml; c. Alprostadil 20 mcg/ml Bupivacaine 0.5% injection solution; d. Alpha Lipoic Acid 25 mg/ml, 30 ml. The firm uses "Frequency as Determined by PIC" rather than a specific frequency. In actual practice, the media fill operations for some products may take up from [illegible] to [illegible]. The media fill operations for the following product sizes were noted as taking extended times: MDV 10 ml vial lot #021215XAA takes about [illegible] to produce; 5 ml vial lot #030215CY takes about [illegible] to produce; vial lot #012315NAN takes about [illegible] to produce.
- Observation 4
Inadequate sterile gowning apparel
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, S.O.P. 2175 Revision 5 titled "Sterile Gowning Procedure" is deficient in that A. Non-sterile gowns, face masks, and booties are allowed to be worn in the ISO 7 and ISO 8 zones. These non-sterile items and sterile gloves are also worn while working in the ISO 5 and ISO 7 environment. On 03/03/2015 we observed a pharmacy technician walking between the ISO 7 and ISO 8 zone of the pharmacy with non-sterile gowning. We observed exposed facial skin during product manipulation of Testosterone Cypionate 200mg/Progesterone 2.5mg per ml lot #030315F in the ISO 7 area. We also noticed that the technician did not change the sterile gloves when he walked from the ISO 7 area into ISO 8 and back into ISO 7 to work on production. B. Employees working in the sterile area is not required to wear sterile goggles.
- Observation 5
Inadequate container closure integrity testing
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product. Specifically, the firm uses [an unspecified crimping] process for sealing the product vials. The firm does not perform any leak test on the vials containing the product to detect leakage through the crimping process.
- Observation 6
Missing pyrogen testing for batches
Each batch of drug product purporting to be pyrogen-free is not tested or produced according to pyrogen testing requirements. A. Alpha Lipoic Acid 25 mg/ml 30 ml lot #0122915NAJ, BUD 0 [illegible]. B. Testosterone Cypionate 200 mg/Progesterone 2.5 mg [illegible]. C. Papaverine/Phentolamine/Alprostadil 22.5/0.83/8.33 [illegible].
- Observation 7
Components not microbiologically tested
Each lot of a component that is liable to microbiological contamination is not tested or treated to ensure it is suitable for use and is not subjected to microbiological tests before use. Specifically, the firm uses multi-dose vials and other components without adequate microbiological testing in the incoming process. The PIC could not verify conformance does not state that [components are tested]. Examples of products include: A. Human Chorionic Gonadotropin 12,000 Units, lot 121214NAZ, BUD 05/23/15, date made 11/24/[illegible]. B. Human Chorionic Gonadotropin 5,000 Units, lot AL-022015XC, BUD 08/[illegible]. C. Papaverine 30 mg/Phentolamine 1 mg/Alprostadil 10 mcg, lot AL-121214NAZ, date made 12/12/14, quantity made [illegible].
- Observation 8
Inadequate product release testing
Testing and release of drug product for distribution do not include appropriate laboratory determination of conformance to the final specifications prior to release. Specifically, the firm has not performed any reconstitution stability or release testing for: Papaverine/Phentolamine/Alprostadil 22.5-0.83-8.33 MDV 5 ml lot 030315CU, BUD 08/30/[illegible].
- Observation 9
Unsupported beyond-use dating/stability
Results of stability testing are not used in determining appropriate storage conditions and beyond-use dating. Specifically, A. The firm does not have a stability procedure and does not conduct stability studies for compounded sterile drug products. Per the PIC, they rely on literature. The following products were assigned BUDs without supportive stability studies: a. Alpha Lipoic Acid 200 mg/ml MDV 30 ml, lot 060414AAK, BUD 09/02/14, date made 06/04/[illegible]. Per the PIC, the firm assigned a 90 day BUD based on literature which the firm did not adhere to. i. "The Beyond Use Date assigned to this formulation is valid only when Equipment and Closure System specified in [illegible] 20 mm Sterile Amber Glass Serum Bottle." ii. "According to USP guidelines, compounded sterile preparations (high risk) cannot exceed... 3 days" - this product was labeled as "Store [at Room Temperature] Protect From Light." b. Testosterone Cypionate 150 mg/Nandrolone 150 mg per ml, 10 ml, lot 021115XAH, BUD 05/[illegible], date made 02/12/15. Per the PIC, the firm assigned a 90 day BUD based on literature which the firm did not adhere to. i. "According to USP guidelines, ..." c. Papaverine/Phentolamine/Alprostadil 22.5-0.83-8.33 MDV, produced 03/04/15. Per the PIC, the firm assigned a 180 day BUD at -23°C based on literature which the firm did not adhere to. i. "According to USP guidelines, compounded sterile preparations... days" "Refrigerate at 4°C, ..." The firm does not have temperature study or procedure for shipping and does not have product stability data for the temperature ranges. The firm does not have shipping validation studies to show that the ice pack is sufficient to keep products within an acceptable temperature range and there is no verification from customers to report if the products received were out of range. Finished products are packaged with an ice pack for pickup and delivery and are being shipped to various locations.
- Observation 10
Incomplete batch production records
Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, the firm does not always have complete information on formula worksheets. A. Alpha Lipoic Acid 25 mg/ml, lot 012315NAN, a. Product label is missing, b. Individual ingredient manufacturer, lot and expiration dates are missing, c. Used Mfr, lot, and Exp are missing, d. Visual inspection and initials are missing. B. Alpha Lipoic Acid 25 mg/ml, lot 012915NAJ, a. Product label is missing, b. [container] is stated to be [illegible], c. used did not have lot # and expiration date listed. C. Papaverine/Phentolamine/Alprostadil 22.5-0.83-8.33 MDV, lot 030315CU, produced 03/04/15, a. Product label is missing, b. potency result was not circled as pass/fail/NA, c. pH information is not filled in.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011014614 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011014614. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.