Drug Crafters
5680 Frisco Square Blvd, Frisco, Texas, United States
FEI 3010660340
FDA has one inspection on file for Drug Crafters in Frisco, Texas (FEI 3010660340). It ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 26, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Improper aseptic technique
OBSERVATION 1 Personnel engaged in aseptic processing failed to follow proper aseptic techniques. Specifically, On 07/02/2018, your firm's pharmacy technician failed to execute proper aseptic technique while producing your firm's sterile drug product, Vitamin C P/F 500 mg/mL, 30 mL volume, Lot #06282018@37, Beyond Use Date: 11/30/2018. I witnessed your pharmacy technician rest her elbows on the front of laminar airflow hood #1, ISO 5 environment, while producing said sterile drug product.
- Observation 2
Exposed skin during aseptic processing
OBSERVATION 2 Personnel engaged in aseptic processing were observed with exposed skin. Specifically, On 07/02/2018, your firm's pharmacy technician presented exposed skin while producing your firm's sterile drug product, Vitamin C P/F 500 mg/mL, 30 mL volume, Lot #06282018@37, Beyond Use Date: 11/30/2018. Your pharmacy technician's skin surrounding her personal eyeglasses was exposed and her sterile gowning did not overlap while producing sterile drug products in your laminar airflow hood #1, ISO 5 environment.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010660340 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010660340. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.