Skip to content

West Coast Nuclear Pharmacy

3906 Cragmont Dr, Tampa, Florida, United States

FEI 3010421557

FDA has one inspection on file for West Coast Nuclear Pharmacy in Tampa, Florida (FEI 3010421557). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Apr 9, 2018 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2018
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Microbial contamination in ISO 5

      Actionable microbial contamination was present in the ISO 5 area or in adjacent areas during aseptic production without adequate product evaluation and remedial action. Specifically, your surface sampling of the ISO 5 laminar flow hood identified the presence of Bacillus spp. on 1/8/2018, and the environmental monitoring procedures did not require additional action such as the sanitization of this hood with a sporicidal agent to remove the spore forming bacteria. You continued sterile radiopharmaceutical drug preparations in this hood. You prepared fixed kits of radiopharmaceuticals such as sestamibi Tc99m lot K-20180321-035 from 1/18/2018 to 3/22/2018.

    2. Observation 2

      Poor aseptic practices observed

      Poor aseptic practices were observed during aseptic preparations. Specifically, on 3/21/2018 we observed the preparation of sodium pertechnetate TcO4 lot E-20180321-018 and kit preparation of sestamibi Tc99m lot K-20180321-035 which are used to prepare patient doses of sestamibi Tc99m lot K-20180321-035. During these operations we observed the following: A. Personnel were observed touching equipment or other surfaces located outside of the ISO 5 area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. Personnel failed to disinfect or change gloves frequently enough to prevent contamination. Sterile gloves worn by employees came in direct contact with non-sterile objects such as the buffer room door, lead pigs, vials, syringes, wipes, computer keyboards and mouse, labels, label printers, and [illegible]. These gloves were then used to perform radiopharmaceutical preparations in the laminar flow hoods. B. Personnel were observed to be moving rapidly in the vicinity of open sterile units or instruments, which disrupted the airflow and increased the risk of bringing lesser quality air to the ISO 5 area. Employees were observed moving quickly in front of the ISO 5 Hood drug preparation area while preparing patient doses of sestamibi Tc99m for injection. These movements included passing single patient doses in lead pigs through sliding glass doors to the non-controlled room while wearing sterile gloves and then returning to the ISO 5 environment without sanitizing the gloves and to continue drawing patient doses.

    Show observations 3 to 7
    1. Observation 3

      Inadequate media fill simulation

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills were not performed that simulate the kit preparation of sestamibi Tc99m which are used to prepare patient doses of sestamibi Tc99m pre-filled syringes.

    2. Observation 4

      Facility design allows poor air influx

      The facility design was observed to allow the influx of poor quality air into a higher classified area. Specifically, the pass through windows located in between the buffer room ISO 7 and the unclassified room are not properly sealed to prevent the mixture of classified and unclassified air. In addition, these pass through windows directly open to the ISO 7 areas that are located in front of your ISO 5 laminar flow hoods.

    3. Observation 5

      Procedure not performed as required

      was not performed. Specifically [illegible] which are located

    4. Observation 6

      Non-sterile wipes used in ISO 5

      Disinfecting agents and cleaning pads or wipes used in the ISO 5 area [aseptic processing areas] are not sterile. Specifically on 3/[illegible] observed that employees were [illegible] non-sterile lint-free wipes to wipe down the walls and surfaces in laminar flow hoods.

    5. Observation 7

      Inadequate surface disinfection scheduling

      The scheduled use of whole room surface disinfection system is [illegible] rather than when [illegible] through environmental monitoring. Specifically, Bacillus spp. was recovered by surface samples taken from the ISO 5 surface area located in the airflow laminar flow hood. This hood was not treated with an anti-sporicidal as a preventative and corrective action to this objectionable organism.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010421557 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010421557. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.