Skip to content

United Pharmacy

3951 Haverhill Rd N, West Palm Beach, Florida, United States

FEI 3010404505

FDA has one inspection on file for United Pharmacy in West Palm Beach, Florida (FEI 3010404505). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Nov 20, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2017
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Microbial contamination during aseptic production

      Observation 1: Actionable microbial contamination was present in the ISO5 area or in adjacent areas during aseptic production without adequate product evaluation and remedial action. Specifically, on 11/29/16 during viable air monitoring conducted by your vendor an Out of Specification (OOS) of Ill (specification Ii) of Aspergillus versicolor was observed in the Negative Pressure Clean Room at location [illegible]. Your firm failed to conduct an adequate investigation and as a result attributed the OOS to be vendor related without any supporting evidence. During this time, your firm released batches based solely on passing sterility testing between 11/30/16-12/15/16. The following batches were distributed: 1. Testosterone Cypionate 210mg/ml 5mL injection (vials), lot # TC-27 BUD: 5/30/17 2. Testosterone 200mg pellets (pellets), lot # PT200-5, BUD: 6/6/17 3. Testosterone 100mg pellets (pellets), lot # PT100-4, BUD: 6/6/17 4. Testosterone Propionate 5mL 100mg/ml injection (vials), lot # TP-10, BUD: 5/30/17 5. HCG 5,000 unit injection (units), lot # HCG5-23, BUD: 6/9/17 6. HCG 6,000 unit injection (units), lot # HCG6-24, BUD: 6/15/17

    2. Observation 2

      Released product with failing potency

      Observation 2: Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, your firm released and distributed approximately [illegible] Testosterone 50mg subcutaneous pellets (compounded 4/21/16), lot # PT50-2, BUD: 10/21/16 despite receiving failing potency test results (dated: 5/27/16) numerous times for low assay (83.4%, 86%, 78.3%) from your firm's contract testing laboratory. The specification for assay by HPLC is [illegible]. The same day, 5/27/16 your firm's contract testing laboratory tested the sample a fourth time and received a passing result of 96.2%. Your firm failed to evaluate the four test results for the same sample (3 failing, 1 passing) and shipped the product without conducting an investigation to invalidate the three OOS results based on scientific rationale.

    Show observations 3 to 8
    1. Observation 3

      Improper gowning technique

      Observation 3: Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, on 8/16/17 during gowning within the ISO5 certified positive anteroom, adjacent to the negative pressure clean room, two operators were observed touching their sterile sleeves against both the door handle leading to the clean room and powder hood located within the anteroom. The ISO 5 certified positive anteroom contains a powder hood, sink and shelving with gowning materials, tubing, glassware, etc., leaving little room for the operators to adequately don sterile gowning.

    2. Observation 4

      Inadequate glove sanitization/change

      Observation 4: Personnel failed to disinfect or change gloves frequently enough to prevent contamination. Specifically, on 8/16/17 during the compounding operations for Testosterone Cyp./Anast. 200mg-0.5mg/mL 5mL injectable, lot # TCA0.5-4, BUD: 1/30/18 within the negative pressure clean room your firm's employees failed to disinfect or change gloves frequently during the following observed instances: 1. The operator sprayed his gloves with sterile [illegible] then touched the drapes leading to the [illegible], the front of them and the chair that he was sitting on and continued his aseptic technique. 2. The same operator during stoppering of the vials dropped the stopper, picked it up with his gloved hand and restoppered the vial containing sterile product. 3. At the completion of [illegible] and prior to filling of the individual vials, the operator was observed moving equipment from the [illegible] to a stainless steel workbench outside of the draped area therefore touching the drapes, equipment and workbench and without re-sanitizing or changing gloves began to fill the individual vials.

    3. Observation 5

      Equipment/supplies not disinfected

      Observation 5: Equipment, materials, and/or supplies are not disinfected prior to entering the aseptic processing areas. Specifically, on 8/16/17 prior to the compounding operations for Testosterone Cyp./Anast. 200mg-0.5mg/mL 5mL injectable, lot # TCA0.5-4, BUD: 1/30/18 within the negative pressure clean room your firm's operators failed to clean/disinfect the following equipment and supplies: 1. The operator failed to clean and sanitize the ceiling and front shield of the [illegible]. 2. The operator failed to wipe down the tray containing sterilized vials before placing it within the [illegible]. 3. The operator failed to wipe down the [illegible] containing non-sterile product before placing it within the [illegible]. 4. The operator failed to wipe down the tubing package before placing it within the [illegible]. 5. The operator failed to wipe the bottom of the repeater pump before placing it within the [illegible].

    4. Observation 6

      Inadequate environmental monitoring

      Observation 6: Environmental monitoring was not adequately performed in your aseptic processing areas. Specifically, on 8/16/17 at the completion of compounding operations for Testosterone Cyp./Anast. 200mg-0.5mg/mL 5mL injectable, lot # TCA0.5-4, BUD: 1/30/18 within the negative pressure clean room your firm's operator failed to adequately conduct surface sampling. When conducting his surface sample of the [illegible] he was observed not applying pressure to the plate therefore the media was not coming in direct contact with the surface. Instead he tapped the edges of the plate and upon removal of the media plate an impression of a ring remained therefore the center of the plate failed to come in contact with the work surface of the [illegible].

    5. Observation 7

      Inadequate media fill simulation

      Observation 7: Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, your firm's media fills fail to demonstrate your current compounding process. For example, there is no documentation of the simulated filling and process. In addition, [illegible] units were filled, but only 60 units were incubated and inspected for growth and turbidity. Your firm failed to provide scientific justification for not incubating and inspecting all units. Your firm also lacks documentation of growth promotion testing for the media used.

    6. Observation 8

      Inadequate post-(b)(4) testing and rationale

      Observation 8: Post (b) (4) testing to the [illegible] was not performed adequately. Specifically, on 8/17/17 your firm's operator conducted a test on the [illegible] used to [illegible] Testosterone Cyp./Anast. 200mg-0.5mg/mL 5mL injectable, lot # TCA0.5-4, BUD: 1/30/18 (compounded on 8/16/17). During the [illegible], your operator opened the [illegible] completely instead of [illegible] the [illegible] as stated in your firm's SOP #3.086, Rev. 1 titled, (b) (4) [illegible], dated 5/1/17. The [illegible] on the tank was closed, therefore when he opened the [illegible] the [illegible]. The operator performed the [illegible] and it failed at [illegible] (specification is a minimum of [illegible]). Your firm stated that this was the first time [illegible] has failed the (b) (4). In addition, your firm failed to provide scientific rationale and supporting documentation to demonstrate that the (b) (4) can adequately sterilize the Testosterone Cyp./Anast. 200mg-0.5mg/mL 5mL injectable which is an oil base product.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010404505 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010404505. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.