Petscript Inc
Paris, TX, United States
FEI 3010282564
FDA has one inspection on file for Petscript Inc in Paris, TX (FEI 3010282564). It ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 16 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 1, in 2025
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Jan 9, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 16 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit and BUD deficiencies
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, a) Your firm has no written procedures outlining the responsibilities of the Quality Unit, including release or rejection of finished drug products. b) Written procedures are not review and approved and have not been assigned effective dates. c) Your firm placed an incorrect Beyond Use Date (BUD) on the label for Lot #25070112 of Estradiol Cypionate 2mg/1 ml Injection. BUD placed on the label was 01/31/2025. d) Media fills performed by your firm with each of the technicians that work in the ISO area do not closely simulate actual production conditions or cover worst case or most challenging conditions. Please refer to [illegible]. e) Your firm's sterilization cycles used to render sterile drug products sterile via [illegible] and/or [illegible] have not been [illegible]. Please refer to OBSERVATION 2 for details. f) Your firm has not validated the cleaning of the stoppers, vials and ointment tubes used to package sterile drug products. g) Your firm is not performing environmental or personnel monitoring in the classified areas (ISO [illegible]/ISO [illegible]/ISO [illegible]). Please refer to OBSERVATION 4 for details. h) Your firm failed to replace a leaking [illegible], failed to perform an investigation and product impact assessment. Please refer to OBSERVATION 6 for details. i) Your firm does not conduct routine testing for sterility, endotoxin as applicable, or potency (assay) for all drug products produced by your firm (sterile and non-sterile). Please refer to OBSERVATIONS 8 & 13 for details. j) Your firm does not have an established stability testing program to justify Beyond Use Dates (BUD) placed on your drug products. Please refer to OBSERVATION 9 for details.
- Observation 2
Aseptic processing not validated
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the aseptic and sterilization process. Specifically, a) Media fills performed by your firm with each of the technicians that work in the ISO area do not closely simulate actual production conditions or cover worst case or most challenging conditions. The media fill your firm performs has the technician filling media into (b)(4) vials and media received with a kit already stoppered and the media is introduced via syringe via the septum. In routine production, your firm fills various size vials (30cc, 50cc and 100cc vials), dropper bottles (5ml, 10ml and 15ml), syringes and ointment tubes. All vials, stoppers and tubes used by your firm are sterilized (b)(4) by [illegible]. Vials are filled and then stoppered by the technician. The technician places the tip and cap on the dropper bottles after filling. Syringes are received sterilized and placed directly into the technician's hands. In addition, documentation of the media fills performed are incomplete in that they do not include how the media was prepared, the order in which media and the volume filled in each, and documentation of consumables such as syringe filters and the water used to reconstitute the media. Your firm uses store brand [illegible] water to reconstitute the media. b) Your firm's sterilization cycles used to render drug products sterile via [illegible] and/or [illegible] have not been validated. Your firm sterilizes some components and then adds them to other [illegible] sterilized components. Examples of finished drug products that are prepared from bulk non-sterile active ingredient that are to be sterilized via [illegible] include: • Corticotropin (ACTH) LA Gel 40U/1ml • Reserpine (Aqueous) 2.5mg/1ml • Xylazine 10mg/1ml Injection Examples of finished drug products that are prepared where the final component is [illegible] include: • Praziquantel 100mg/1ml Injection • Estradiol Cypionate 2mg/1ml IM Injection • Cyclosporine 0.2% Sterile Ophthalmic Solution Other examples include • Chloramphenicol 1% Sterile Ophthalmic Ointment • Edetate Disodium (EDTA) 1% Ophthalmic Ointment • Gentamicin 0.4% (4mg/1ml) • Itraconazole 1% in 10% DMSO Sterile Ophthalmic Ointment c) Smoke studies performed in [illegible] are not representative of all activities performed. For example, during filling of lot #25090389 of Tacrolimus 0.02% Ophthalmic Solution, there were [illegible] stoppers and caps propped up against the face of the HEPA filter and side of the Laminar Flow Hood, tray of (b)(4) vials, beaker of (b)(4) on a hot plate, and some packaged syringes. In the smoke study video dated 09/04/2025, there is only the hot plate and a spray bottle inside the LFH.
Show observations 3 to 16
- Observation 3
Inadequate microbiological procedures
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not adequate. Specifically, a) Your firm has no written procedure for how to perform [illegible] specifications for pass/fail of the test. Your firm does not have defined testing of (b)(4) used to make sterile drug products. (b)(4) b) Stoppers and caps are removed from their original packaging and placed on the surface of the LFR when filling. The technician then places the stopper onto the vial using their gloved hand. When filling sterile drug products into dropper bottles the tips and caps are also manually placed onto the dropper bottle by the technician. c) On 09/12/2025 I watched the filling of lot #25090389 of Tacrolimus 0.02% Ophthalmic Solution. There were [illegible] stoppers and caps propped up against the face of the HEPA filter inside the ISO Laminar Flow Hood.
- Observation 4
Environmental monitoring deficiencies
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) Your firm is not performing environmental monitoring in the classified areas (ISO [illegible]/ISO [illegible]/ISO [illegible]) that sterile drug products are produced. Your firm is not performing viable surface sampling and viable active air sampling and viable particulate monitoring in your rooms and hoods on a routine basis nor when your rooms and hoods are certified. In addition, your firm does not perform non-viable particulate monitoring in the Laminar Flow Hood during production. Your firm is not monitoring each operator working in the ISO room when drug products are prepared (b)(4) when a media fill is performed. b) Your firm is not performing environmental monitoring during media fills.
- Observation 5
Inadequate personnel gowning
Clothing of personnel engaged in the manufacture, processing, packing and holding of drug products is not appropriate for the duties they perform. Specifically, gowning for personnel working in the ISO classified areas consists of the following: scrubs worn from home, a disposable sterile 'field gown', non-sterile hair net, non-sterile face mask, and non-sterile shoe covers. Gloves are donned after the technician has donned the other gowning materials. The gowning requirements leave exposed skin around the eyes, forehead and neck of the person preparing sterile drug products. Gowning in the ISO prep area consists of scrubs worn from home. There is no requirement for a hair net or any other protective clothing while preparing/mixing sterile drug products.
- Observation 6
Failure to investigate HEPA leaks
There is a failure to thoroughly review any unexplained discrepancy or to thoroughly investigate the cause of a batch failure when the batch has been already distributed. Specifically, during the certification of the cleanrooms on 09/05/2024 and 03/07/2025, one of the HEPA filters in Room [illegible] (ISO [illegible]) needed attention due to leaks detected. The report does not note the size of the leaks. The HEPA filter was not replaced until 09/04/2025. Your firm did not perform an investigation into the leaking HEPA filter or perform a product impact assessment. Your firm does not maintain a log of all lots made in each of the cleanrooms; however, from 09/05/2024-03/07/2025, your firm made approximately [illegible] lots of sterile drug products.
- Observation 7
Unvalidated container/closure processes
Drug product containers and closures were not clean and sterile, nor have their pyrogenic properties been evaluated to assure that they are suitable for their intended use. Specifically, a) Your firm has not validated the cleaning of the stoppers and vials used by your firm to package sterile drug products. b) Your firm has not validated the re-sterilization of stoppers. According to your technician who works in the cleanroom producing/filling, unused rubber stoppers that have already been processed can be placed back into inventory and processed again. Your firm has no system for tracking the rubber stoppers that may have been subjected to the sterilization process more than once. c) Your firm initially sterilizes stoppers and caps and at the time of use the technician will remove a certain quantity of stoppers and caps from each lot prepared on a given day and place them into a new (b)(4) for storage. At the beginning of each shift a new batch of stoppers and caps are taken for use. Your firm has not validated this process to ensure that all stoppers and caps remain sterile throughout the timeframe used post initial sterilization.
- Observation 8
No sterility/endotoxin testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, your firm is not testing any of your drug products labeled as sterile for sterility and/or endotoxin prior to release/distribution.
- Observation 9
No stability testing / BUD justification
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, your firm does not have a written stability testing program to determine Beyond Use Dates (BUD) placed on all your drug products. Your firm has no written stability protocols and no final written and approved reports. Your firm has not performed container closure integrity testing when applicable. Your firm has no documentation of a stability study having been performed to justify the Beyond Use Dates (BUD) placed on your sterile and non-sterile drug products. Examples include: i. Lot #24050745 of Xylazine 10mg/1ml Injection had a BUD of 200 days ii. Lot #25080172 of Estradiol Cypionate 2mg/1ml IM Injection had a BUD of 205 days iii. Lot #25070632 of Reserpine (Aqueous) 2.5mg/1ml Injection had a BUD of 187 days iv. Lot #25060197 of Praziquantel 100mg/1ml Injection had a BUD of 209 days v. Lot #25070372 of Gentamicin 0.4% (4mg/1ml) had a BUD of 199 days vi. Edetate Disodium (EDTA) 1% Ophthalmic Ointment had a BUD of 195 days. Lot #2508213 had a BUD of 204 days. vii. Lot #25040770 of Ponazuril [illegible] viii. Lot #25070449 of Febendazole 200mg/1ml [illegible] ix. Lot #25050407 of Pimobendan 10mg Quadrisect Tablets had a BUD of 374 days
- Observation 10
Unvalidated cleaning procedures
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, your firm has not validated the cleaning of beakers and other items used to make both sterile and non-sterile drug products. Most equipment, beakers and utensils used for sterile and non-sterile drug products are first cleaned with store brand liquid dish soap and sponges or scrub brushes. The glass, utensils and some other items used for non-sterile drug products are then placed into a dishwasher using store brand dishwashing detergent. Your firm has no documentation to show that these soaps and detergents are appropriate and suitable for the preparation of pharmaceutical products. Dies and punches used to make tablets are cleaned but the firm has not evaluated the effectiveness of the cleaning process for ingredients used to make tablets such as metronidazole benzoate.
- Observation 11
Incomplete batch records
Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, your firm's batch records do not contain documentation of each significant step in the production of drug products. a) Your firm used a (b)(4) for lot #25050100 of Itraconazole 1% in 10% DMSO Sterile Ophthalmic Ointment made on 05/07/2025. (b)(4) is to be used. b) Your firm does not record the lot number of the caps, dropper bottles, syringes, and bottles used to package finished dosage drug products (sterile and non-sterile). c) Your firm does not record in the batch record the lot number, brand and size of the filter used for any sterile drug product. d) Your firm fills sterile and non-sterile drug products into containers labeled as stock which you will then later use to fill finished product containers and label for shipment to a customer. Your firm does not document the filling of product from stock products, including the date performed, the packaging container used, the label placed on the product and the quantity. In addition, if flavoring or other ingredients are added to the stock solution, your firm does not document the identity of the ingredient used.
- Observation 12
Inappropriate incubator conditions
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, drug product containers, closures, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, a) Your firm is incubating media fill vials at a temperature above documented in the Incubator Monitoring Log. For example, the Incubator Monitoring Log for media fill vials incubated from 01/29/2025-02/26/2025 ranged from 35°C-40°C. The temperature documented in the Incubator Monitoring Log for media fill vials incubated from 04/29/2025-05/14/2025 ranged from 34°C-44.4°C. The temperature documented in the Incubator Monitoring Log for media fill vials incubated from 08/01/2025-08/14/2025 ranged from 33.4°C-36°C. b) Your firm is incubating [illegible] at the same temperatures listed above for the media fills. Your firm has not documented that an incubation period of this duration and at this temperature is appropriate and does not adversely affect the agar.
- Observation 13
No potency (assay) testing
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. Specifically, your firm does not conduct routine testing for potency (assay) for any drug products produced by your firm (sterile and non-sterile).
- Observation 14
Inadequate component testing
Written procedures are lacking which describe in sufficient detail the receipt, identification, sampling, testing, approval and rejection of components. Specifically, your firm is using a grocery-store brand water to make sterile drug products. Your firm does not perform testing (analytical or microbiological) to show the water at least/at minimum meets the specifications for (b)(4) water. The use of this water is not appropriate for pharmaceutical use. Examples of items made with this water include the gelatin base used to make chewable treats such as lot #25080231 of Pimobendan 1.25mg Chewable Treat and lot #25060237 of Fluoxetine 10mg Chewable Treat. Sterile drug products made with [illegible] include the 2.5% Gel used to make Corticotropin (ACTH) 40U/1ml.
- Observation 15
Supplier reports accepted without validation
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier. Specifically, your firm is preparing various sterile and non-sterile drug products from bulk drug substances. Your firm does not perform any testing of bulk drug substances or excipients used to make these products.
- Observation 16
Calibration and weighing controls lacking
Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance. Specifically, your firm is not bracketing balances used to weigh raw materials and/or perform in process weight checks during the preparation of sterile and non-sterile drug products. In addition, your firm has no documentation of a weight set used to perform verification of the balances.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jan 9, 2026. It asked for a Form 483.
Inspection ending Sep 18, 2025Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Jan 9, 2026FDA-FOIA-2026-311Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010282564 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010282564. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.