Country Pork
21494 105th St Sw, Renville, Minnesota, United States
FEI 3010264234
FDA has 2 inspections on file for Country Pork in Renville, Minnesota (FEI 3010264234), from 2013 to 2019. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 2, 2013–2019
- 0 OAI · 0 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Daily review of production records
The batch production records are not checked by a responsible individual at the end of the working day to determine whether all required production steps have been performed.
Elements of the Master Record File
The Master Record File does not contain the name and weight percentage or measure of each drug or drug combination and each nondrug ingredient to be used in manufacturing a stated weight of medicated feed, a copy or description of the label that will accompany the medicated feed, manufacturing instructions or reference thereto that have been determined to yield a properly mixed medicated feed of the specified formula for each medicated feed produced, appropriate control directions including the collection of samples for specified laboratory assays, and the basis for estimating quantity produce
Scales and metering devices
The scales are not of suitable design for their intended purpose.
Three assays per year
Periodic assays are not performed during the calendar year on at least three representative samples of medicated feeds requiring a medicated feed mill license, for each drug or drug combination used.
Maintaining records of complaints
The original or copy of a record of each oral or written complaint received relating to the safety and effectiveness of the product produced is not maintained on the premises.
Show 5 more citations
Daily inventory record kept
Failure to maintain a daily inventory record for each drug used in the manufacture of medicated feeds.
Integrity and identity
Failure to properly identify and store drugs in the mixing areas to maintain their integrity and identity.
Elements of receipt record
Drug receipt records do not accurately indicate the supplier's lot number or other identifying number, date of receipt, and condition of the drug when received for each lot of drug received.
Daily reconciliation, Investigation/corrective action of actual vs theoretical
A daily comparison is not made between the actual amount of drug used and the theoretical amount of drug to be used in terms of the finished medicated feeds manufactured.
Appropriate labeling for medicated feed
Medicated feed is not identified by appropriate labeling which provides the user with directions for use which if adhered to, will assure the article is safe and effective for its intended purpose.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 225.42Components1 of 1
- 21 CFR 225.58Laboratory controls1 of 1
- 21 CFR 225.80Labeling1 of 1
- 21 CFR 225.102Master record file and production records1 of 1
- 21 CFR 225.115Complaint files1 of 1
- 21 CFR 225.130Equipment1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010264234 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010264234. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.