Biocon Limited
Sez Plot No. 2,3, 4 & 5 Phase Iv, Bommasandra Post, Bommasandra-Jigani Link Road, Bengaluru, India
FEI 3010164491DUNS 915076162
Company: Biocon Limited · Linked by exact D-U-N-S match (650840940) in FDA registration data
FDA has 3 inspections on file for Biocon Limited in Bengaluru, India (FEI 3010164491), from 2016 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, Biocon Limited (D-U-N-S 650840940), has registered 4 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2016–2024
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate cleaning validation protocols
1. Cleaning Validation Protocols designed to assess potential product-to-product carryover in non-dedicated, are not adequately performed. Specifically, Per SOP No. QA/SOP/016, "Cleaning Validation", the result". Cleaning Validation Protocols are product specific and define the process, procedures, materials and documentation requirements. During execution of the cleaning validations, the performed cleaning actions are documented on the respective "Equipment Cleaning Checklist", while details "Technical Information Sbeet for Equipment Cleaning Checklist" or "Technical Information Sheet for Equipment Cleaning Sample". However, neither the "Equipment Cleaning Checklist" nor the "Equipment Cleaning Sample" document the diluent used in the swab sample collection preparation, volume of diluent, total area swabbed, as required by the respective protocol and SOP No. QA/SOP/016.
- Observation 2
Inadequate OOS investigations
2. Failure to perform adequately investigate non-conformances. Investigations into Out-of-Specification impurities test results, failed to assess the potential impact (b)(4). (b)(4) settings unngr c1 not documented within production batch records prior to implementation PC/19/040, which has a tentative closure date of March. Per written procedure SOP No. QA/SOP/057, "Materials and Products/Batch Failures", Version 17, "When (OOS investigation) should be initiated". A total of 21 (b)(4) (for US distribution) from January 2015 to January 2020, with 3 escalated to Phase II. However, deficiencies contributing factor until an OOT impurity result was reported (BP1/00T/19/011), of an impurity content of >>1" % (OOT Action Limit of H > ?/o). Technical Report PEL!fR/BL.14.0625/19/003.
Show observations 3 to 5
- Observation 3
Equipment qualification deficiencies
3. Equipment used in production operations are not adequately qualified. Specifically, A. During execution of BP/PROD-CQC/17/P/002-00, ID No. C1IS-2078, test pieces were created from pieces of an (b)(4) removed; there was no documentation present to ensure the composition of the generated test pieces. Additionally, the acceptance criteria established in the qualification protocol was established as (b)(4). However, the mass of the generated test samples was not weighed prior to, nor after completion, to ensure 100% recovery. The "Report" (Report No. BP/PROD-CIC/17/R/002-00, approved on August 31st, 2017) relied on visual verification of 100% recovery, to satisfy the acceptance criteria. (b)(4) design...qualified in a similar manner, are used in the production of drug substance and USP; furthermore, these (b)(4) (b)(4) (b)(4) have previously been observed during production. B. No verification was performed during qualification of operational parameters for (b)(4). C. HM1 assigned fixed-recipes for operational parameters, are non-dedicated to a production block in the manufacture of finished API product, to be distributed to the US market. Test pieces used to challenge (b)(4) (b)(4) used in the production of (b)(4) were not traceable to any certified standard to verify composition.
- Observation 4
Quality control documentation failures
4. Failure to fulfil the responsibilities of the Quality Control Review, verification and control of documents involved in Approval/Quarantine/Reject of intermediate and finished API products are deficient. For example, A. No records are generated or verified with respect to Approval/Quarantine/Reject labels applied to in-process, intermediate, or finished API product. Labels are generated using word processing software; labels are not verified for accuracy in regard to Batch No., Inspection Lot No., or Retest Date, prior to being affixed to product containers. Additionally, no reconciliation of generated labels were observed with "Under Test" and "Sample Pack" labels. B. Master Batch Record documentation were observed without requiring documentation of critical process parameters. Executed batch records were similarly reviewed and approved with product subsequently released, without documentation of critical process parameters. C. Multiple copies of forms/log-sheets are generated and provided to various departments. Multiple forms documenting actions during the same time period were observed. Additionally, documents were observed with data entered prior to the documented QA issuance date. D. The sterility of purchased containers has never been assessed or verified. Supplier qualification (CQCM/SOP/039, "Receipt, Storage, and Handling of Consumables", Effective Date: October 23rd, 2018) does not ensure that the containers, which are defined as "critical consumables", are sterile upon receipt. E. Transportation of Microbiological samples for Identification, "Transport of Microbiology Samples", Version 02, Effective Date: May 25th, 2018, does not require documentation of the temperature conditions during transport of microbiological (Environmental Monitoring, Cleaning Validation) samples.
- Observation 5
Material handling and storage deficiencies
5. Failure to adequately handle, store and document material movement and status. Specifically, materials of different status were observed on January 23rd, (b)(4) (b)(4) storage, and to be commingled. Material placards incorrectly identify the status of the storage shelf contents. Additionally, inventory records tracking the inward/outward, sampling and disposition of materials, were observed to be inaccurate. No use of "Reject" labels was observed in any product despite the requirement of such, per SOP No. PROD/SOP/003, "Department Functional Procedure", Version 12, effective date: April 4th, 2018.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Biocon LimitedD-U-N-S 650840940
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Biocon Limited (D-U-N-S 650840940) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Biocon Biosphere LimitedParavada, India · FEI 30221253401 inspection1latestNov 7, 2025VAINone on file
- Biocon LimitedBangalore, India · FEI 10001729126 inspections6latestSep 20, 2024VAINone on file
- Biocon LimitedParavada, India · FEI 30064005913 inspections3latestJun 21, 2024VAINone on file
- Biocon LimitedSangareddy, India · FEI 30049568553 inspections3latestMay 19, 2023NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3010164491 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3010164491. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.