Skip to content

Advanced Nutriceuticals, LLC

836 E 86th St, Indianapolis, Indiana, United States

FEI 3010039017

FDA has one inspection on file for Advanced Nutriceuticals, LLC in Indianapolis, Indiana (FEI 3010039017). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 10 citations from this inspection. They are listed below. One FOIA request has asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations Division III). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2024
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
1 request, latest Jan 27, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Personnel moving quickly, disrupting unidirectional airflow

      Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow.

    2. FDCA 501(a)(2)(A)

      Production areas, difficult to clean/particle generating

      Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces.

    3. FDCA 501(a)(2)(A)

      Exposed to lower quality air/ISO 5

      Materials were exposed to lower than ISO 5 quality air.

    4. FDCA 501(a)(2)(A)

      Media fills, failure

      Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

    5. FDCA 501(a)(2)(A)

      Non-sterile disinfecting agents, ISO 5 area/classified areas

      Use of non-sterile cleaning pads and cleaning wipes in the ISO 5 area.

    Show 5 more citations
    1. FDCA 501(a)(2)(A)

      Sporicidal agent, ISO 5/classified areas

      Use of a sporicidal agent in the facility's was infrequent.

    2. FDCA 501(a)(2)(A)

      Contamination, production area/adjacent areas

      Contamination was observed in your production area and areas adjacent to production areas.

    3. FDCA 501(a)(2)(A)

      Lack of disinfection, equipment/supplies from lower to higher quality air

      Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air.

    4. FDCA 501(a)(2)(A)

      Location, ISO 5 classified area

      The ISO 5 classified area is located within a non-classified room.

    5. FDCA 501(a)(2)(A)

      Vermin, production area/adjacent areas

      Vermin or other animals or evidence of their presence was observed in the areas adjacent to production areas.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jan 27, 2025. It asked for a Form 483.

  • Inspection ending Nov 22, 2024VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jan 27, 2025FDA-FOIA-2025-735Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010039017 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010039017. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.