Samsung Bioepis Co., Ltd.
76 Songdogyoyuk-Ro, Yeonsu, Korea (the Republic of)
FEI 3010031951DUNS 557822226
FDA has 4 inspections on file for Samsung Bioepis Co., Ltd. in Yeonsu, Korea (the Republic of) (FEI 3010031951), from 2016 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below. Two of the four FOIA requests for this site have asked FDA for this inspection's records.
1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for analysis, through Dec 31, 2027. Its registrant is Samsung Bioepis Co., Ltd. (D-U-N-S 557822226).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2016–2024
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 4
- Requested under FOIA
- 4 requests, latest Apr 25, 2025
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Complaint handling procedures deficient
OBSERVATION 1 Procedures describing the handling of written and oral complaints related to drug products are not written and/or followed. Specifically, A. Your complaint handling procedure, SOP-GxP-CML-00944 Version 13.0 Product Quality Complaints Management (Effective date 8/23/2024) does not have a timeline assessment for the market complaints. Your Senior Manager Quality Assurance stated that initial assessment is generally done within [illegible]. One 1/9/2024, you recorded Complaint # PC-016468 for Particulate in two vials of (b)(4) mg Vial Lot No's (Mfg. date 6/20/2023, (Mfg. date 8/14/2023, Expiry date [illegible]). According to your procedure, criticality classification for particulate matter in drug product is High/Class 1 that requires to complete the investigation within [illegible]. You did not complete the Initial Assessment until [illegible] of recording the complaint. You did not launch an investigation report (initial assessment), you decided coring and classified the complaint as Medium. On [illegible] you extended and finally closed the complaint on 4/3/2024. B. On 7/18/2024 you recorded Complaint # PC-017796 for a "spot, like an ink mark" (Particulate) inside a vial of (b)(4) mg Vial Lot No's (b)(4). According to your procedure, criticality/classification for particulate matter in drug product is High/Class 1 that requires to complete the investigation within [illegible]. You did not complete the Initial Assessment until [illegible] of recording the complaint. On the field report (initial assessment), you classified the complaint as Particulate and, based on the visual inspection, you decided [illegible] but a spot with black color was found located on the outer surface of the vial approximately [illegible] mm, which is less than the minimum criteria for a defect. Based on your investigation, you assessed the complaint as 'non-conforming'. The investigation was closed on 11/19/2024 but the complaint is still open as of 11/22/2024. C. On 11/3/2023 you recorded Complaint # PC-016044 Particulate inside a vial of (b)(4) mg Vial Lot No's (b)(4) (Mfg. date 5/22/2023, Expiry date [illegible]). According to your procedure, criticality classification for particulate matter in drug product requires to complete the investigation within [illegible]. After the initial assessment, you decided particulate matter in the drug product was because of coring and classified the complaint as Medium and did not conduct any investigation. D. On 5/21/2024, you received a customer complaint that stated, "***the [illegible] of the vial disconnected and fell through***." On the same day 5/21/2024 you recorded this Complaint # PC-017396 wrongly as Particulate inside a vial of (b)(4) (Mfg. date 2/7/2024, Expiry [illegible]). According to your procedure, criticality classification for particulate matter in drug product is High/Class 1 that requires to complete the investigation within [illegible]. You did not complete the Initial Assessment until [illegible] of recording the complaint. Based on the [illegible], you visually checked the defective vial and concluded [illegible] identified that would increase risk related to the claimed product. Your report did not include any test of the Particulate to confirm the material identified, and the complaint was assessed as 'Non-conforming'. E. Between January [illegible], 2023 and November 15, 2024, you received 335 market complaints for (b)(1) mg (b)(1). Table 1 summarizes some device complaints. You did not conduct [illegible] Manager Quality Assurance (1LC61 stated that the reported defects were within Acceptance Quality Level (AQL) and alert level as set by the firm procedure, SOP-GxP-CML-00944 Version 13.0. In your procedure, the AQL is not reflective to critical defects and the alert level is based on historical data. Table 1. Selected market complaints Type of defect Activation failure — Number of complaints 52 Injection failure — Number of complaints 84 Leakage-before injection-from
Shortened here; the PDF has the full text.
- Observation 2
Undefined quality/BPDR responsibilities
OBSERVATION 2 Responsibilities and procedures for quality units are not in writing and/or Biological Product Deviation Report (BPDR) are adequately assessed and reported products that are implicated with product quality issues. Specifically, The Quality Agreement Between [illegible] does not define the roles and responsibility for Biological Product Deviation Report (BPDR). According to the QA, you are responsible for handling and investigating all quality related issues (Complaint) but determining a need for submitting BPDR is not defined in the Quality Agreement.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringPosted 483 · 2 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reporting Requirements - submission of reports
Failure to submit each post marketing 15-day alert and post marketing 15-day alert follow up report as required.
General responsibilities of sponsors
Failure to ensure proper monitoring of the study, ensure the study is conducted in accordance with the protocol and/or investigational plan and ensure that FDA and all investigators are promptly informed of significant new adverse effects or risks.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Apr 25, 2025.
Inspection ending Nov 22, 2024VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Apr 25, 2025FDA-FOIA-2025-3754EIRClosed
- Mar 20, 2025FDA-FOIA-2025-2580Form 483· 1 of 2 sitesClosed
Inspection ending Sep 15, 2023VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Dec 2, 2024FDA-FOIA-2024-10484EIRDelogged (not a FOIA Request)
- Jun 6, 2024FDA-FOIA-2024-4970Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 4 inspections.
- 21 CFR 312.50General responsibilities of sponsors1 of 1
- 21 CFR 600.80Postmarketing reporting of adverse experiences1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3010031951, one row per refused product line.
1 refusal on 2026-06-01 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2026-06-01
ADALIMUMAB-BWWD58SDK01
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of West Coast ImportsNSA-0032187-7/10002/1
FDA drug establishment registration
FDA registration search- Registered operations
- Analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Samsung Bioepis Co., Ltd.D-U-N-S 557822226
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010031951 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010031951. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.