FDA has 2 inspections on file for Prescription Labs Inc dba Greenpark in Houston, Texas (FEI 3009712882), from 2017 to 2021. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2017–2021
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Exposed skin during aseptic processing

      Personnel engaged in aseptic processing were observed with exposed skin. Specifically, on 7/2/2021, I observed your pharmacy technician while aseptically processing the sterile drug product, Vancomycin-PF Ophthalmic 1.5% 10ML Soln, Lot# (b)(4), BUD 7/30/2021, Qty [illegible] units break the plane of the ISO 5 LAFU, exposing [illegible] facial skin while wearing a non-sterile hairnet, non-sterile eyeglasses, and non-sterile face mask inside the ISO 5 LAFU, which may directly affect drug quality. This is a repeat observation.

    2. Observation 2

      Dispensed OOS or expired products

      Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, during a review of selected 3rd Party Contract Laboratory Sample Results, I found your pharmacy failed to reject out of specification products before and after dispensing them to patients and dispensed the drug product after the beyond use date. Additionally, your pharmacy continued to dispense after laboratory OOS results were received. For example: A. Sample ID - Sample, Chlorhexidine 0.02% Ophthalmic, Lot# (b)(4), Assay exceeds specification (b)(4) Actual results (b)(4) (Retest) (Test Date: 11/17/2020), (b)(4) (Retest) (Test Date: 11/20/2020), (b)(4) (Test Date: 11/16/2020), & (b)(4) (Average) (Test Date: 11/16/2020) (Laboratory Received 11/12/2020), BUD 2/22/2021. Prescriptions dispensed from lot include: a. (b)(6), Dispensed Date: 10/22/2020 b. Dispensed Date: 9/30/2020 c. Dispensed Date: 9/8/2020 d. Dispensed Date: 9/16/2020 e. Dispensed Date: 9/4/2020 f. Dispensed Date: 10/1/2020 g. Dispensed Date: 10/7/2020 h. Dispensed Date: 11/23/2020 & additional patient-specific prescriptions dispensed prior to test completion date B. (b)(4) Tacrolimus PF 5ml Aqueous Ophthalmic suspension 0.02%, Lot# (b)(4), specification (b)(4), Actual Results (b)(4) (b)(4) (Laboratory Test Date: 7/16/2020), BUD 10/24/2020. Pharmacy dispensing patient-specific prescriptions include: a. (b)(6), Dispensed Date: 6/26/2020 C. Sample ID - (b)(4) Lab Report (2), Spironolactone Ophthalmic Solution, Lot# (b)(4), Laboratory Received 8/27/2020 / Laboratory Test Completed: 10/10/2020, specification (b)(4), Results (b)(4), BUD 2/20/2021. Pharmacy dispensing patient-specific prescriptions include: a. (b)(6) Dispensed Date: 8/20/2020 b. Dispensed Date: 8/25/2020 c. Dispensed Date: 8/27/2020 d. Dispensed Date: 10/21/2020 e. Dispensed Date: 10/16/2020 f. Dispensed Date: 9/4/2020 g. Dispensed Date: 9/3/2020 D. Sample ID - (b)(4) Lab Report, Mitomycin Ophthalmic Syringe Solution, Lot# (b)(4), Laboratory Received 6/28/2021 / Laboratory Test Date Completed: 7/9/2021, Specification (b)(4), Results (b)(4), BUD 6/4/2021. I found the pharmacy dispensed the drug product 20 days after the BUD. Pharmacy dispensing patient specific prescriptions include: a. (b)(6), Dispensed Date: 6/24/2021

    Show observations 3 to 10
    1. Observation 3

      Missing sterilization component testing

      used to sterilize products. Specifically, your pharmacy failed to perform a (b)(4) test on all sterile (b)(4) used to render the drug product, Spironolactone-PF-Ophth Each 15ML, 0.005 MG/ML Soln of 770ML, Lot # (b)(4), BUD 1/26/2022 sterile. For example, your pharmacy uses (b)(4) [illegible].

    2. Observation 4

      ISO 5 airflow and storage issues

      No assurance that sterile drug products were processed and stored under ISO 5 quality air. Specifically, A. On 8/2/2021 while visually observing your pharmacy technician aseptically process the drug product, Spironolactone-PF-Ophth Each 15ML, 0.005 MG/ML Soln of 770ML, Lot # (b)(4), BUD 1/26/2022, dropper container kit packages and bottles were observed blocking the return vent in the ISO 5 LAFU while the technician was aseptically [illegible] the Spironolactone-PF Ophthalmic and then transferring to the eye dropper bottles. B. On 8/2/2021, I observed sterile (b)(4) used to render the drug product, Spironolactone-PF Ophth Each 15ML, 0.005 MG/ML Soln was hanging from the ISO 5 LAFU in a manner that would prevent the movement of first pass air. C. Tacrolimus-PF Aqueous Ophthalmic 5ML 0.2% Suspension processing includes (b)(4) preventing the movement of first pass air. Tacrolimus PF Aqueous Ophthalmic does not undergo other sterilization steps after the (b)(4); therefore there is no further sterilization step to the process.

    3. Observation 5

      ISO-5 not certified dynamically

      ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions. For example, on July 15, 2021, your pharmacy failed to recertify the airflow, air quality, and performed no environmental monitoring prior to resuming aseptic production resulting from the replacement of the (b)(4) AC unit designated for the entire cleanroom and ISO 5 LAFU built into the room (non-standalone unit); where aseptic processing occurs. The designated AC unit provides both the make-up air and cooling for all areas of the cleanroom. Your firm management reported only cleaning occurred with no justification for not performing a recertification prior to resuming aseptic production activities.

    4. Observation 6

      Cleanroom design allows air influx

      The facility design was observed to allow the influx of poor quality air into a higher classified area. Specifically, A. No HEPA filter coverage is available for the (b)(4) located in cleanroom for Suite (b)(4) Room and Suite (b)(4) Room, cleanrooms containing LAFU and BSC, which may potentially allow the influx of poor quality air into a higher classified area. Furthermore, there are spaces between and edges of the doors. B. (b)(4) doors are designed with no continuous monitoring and no alarms in place to notify of changes in differential pressure in the event both doors are opened simultaneously along with spaces between and edges.

    5. Observation 7

      Inadequate hazardous drug containment/cleaning

      Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, your pharmacy failed to establish procedures for the deactivation of hazardous drug components used in the production of sterile and non-sterile drug products. For example: A. Your pharmacy produced the sterile drug product, (b)(6) Testosterone Cypionate in Sesame Oil Injection, 10ML 200mg/ML Solution within Cleanroom Suite (b)(4). Your pharmacy also uses the same aseptic process suite for other non-hazardous drug products. Your pharmacy president and technician reported no special cleaning practices other than using sterile (b)(4) and (b)(4). The sterile (b)(4) is used (b)(4). No deactivation agents are used. B. Your pharmacy produced the non-sterile drug product, Biestrogen (50/50) 1.8MG/ML 0.18% Cream, (b)(4), BUD 1/12/2022 in the same non-sterile production area as the drug product, (b)(6) (b)(4) Clobetasol in (b)(4) each 60GM 0.05% CREAM, Lot# (b)(4), BUD 10/2/2021. Your pharmacy technician reported no special cleaning agents/practices are used to deactivate hazardous drug components. The technician reported the pharmacy uses only (b)(4) non-sterile (b)(4) to clean surfaces, utensils, and equipment, and continued in stating utensils may be washed using (b)(4).

    6. Observation 8

      No biological indicators used

      You did not appear to use biological indicators (BIs) during (b)(4) and (b)(4) of finished drug products. Consequently, it is unclear if the sterilization conditions are adequate for inactivating all potential microbial contamination. Specifically, your pharmacy utilizes (b)(4) without the use of bio indicators. For example, no bio indicators were used while (b)(4) the drug product, (b)(6) Testosterone Cypionate in Sesame Oil Injection 10ML 200mg/ml SOLN, Lot# (b)(4), BUD 11/1/2021; Atropine Sulfate Ophthalmic 10ML 0.2% Solution, Lot # (b)(4), BUD 9/27/2021; and (b)(6) Hydroxyprogesterone in Sesame Oil Injection 5ML MDV* 250MG/ML SOLN, Lot# (b)(4), BUD 11/23/2021.

    7. Observation 9

      Inadequate media fill simulations

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, your pharmacy employees' media fill reports dated 2/1/2021 and procedure, "Personnel Aseptic Media Fill Testing and Process, P-402.2", Section 6.2, Sample Procedure for High Risk Level Compounding; failed to adequately represent your pharmacy's most complex aseptic manipulation activity. For example, your pharmacy's media fill procedure failed to include representative manipulation activities, documented within the sterile drug product, Acetylcysteine Ophthalmic each 10ML 10% Soln, Lot # (b)(4), BUD 9/21/2021, which was dispensed to patient-specific prescription, (b)(6). Media fill simulation selection are to represent the most difficult aseptic manipulations and most interventions, which has the potential of introducing microbials and/or alter the final drug quality through stressing the aseptic technique and ISO 5 processing area. Acetylcysteine Ophthalmic each 10ML 10% Soln has a batch sizes of (b)(4) units, whereas your pharmacy's media fill procedure, Personnel Aseptic Media Fill Testing and Process, P-402.2 for aseptically processing requires only (b)(4) units.

    8. Observation 10

      ISO-5 recertification not dynamic

      ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational (dynamic) conditions for your pharmacy's documented recertification report for the ISO 5 LAFU and ISO 5 BSC dated 8/9/2021.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 2

      Non-sterile glove sanitizer used

      OBSERVATION #2 On 10/17/17, an operator was observed sanitizing his gloved hands with non-sterile (b) (4) and then resuming aseptic processing in the ISO 5 area.

    2. Observation 5

      No evidence of required sterilization testing

      OBSERVATION #5 There is no evidence that (b) (4) [illegible] testing is being performed for sterile products. For example, A. Tacrolimus Aqueous Ophthalmic 10 mL 0.03% Suspension, lot #08312017@45 (Production date: 8/31/17 Beyond Use date: 12/29/17) was sterilized using a (b) (4). There was no evidence that the (b) (4) (b) (4) test was performed.

    Show observation 6
    1. Observation 6

      Sporicidal contact time not substantiated

      OBSERVATION #6 The use of the sporicidal disinfectant (b) (4) in the ISO 5 areas is inadequate in that the contact time of [illegible] minutes has not been substantiated.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009712882 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009712882. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.