Skip to content

Reliance Life Sciences Private Limited

Ttc Area Of Midc, R - 282 Dhirubhai Ambani Life Sciences Centre; Thane Belapur Road, Navi Mumbai, India

FEI 3009510975DUNS 650213072

FDA has 8 inspections on file for Reliance Life Sciences Private Limited in Navi Mumbai, India (FEI 3009510975), from 2013 to 2026. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.

1 import refusal is filed under this FEI, on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Reliance Life Sciences Private Limited (D-U-N-S 650213072).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
8, 2013–2026
2 OAI · 4 VAI · 2 NAI
Inspections with 483 observations shown
1 of 8
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest May 29, 2026
Import refusals
1 refusal
Import alerts
66-40Red List
Matched on FDA’s firm name and street address
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete laboratory and EM data

      OBSERVATION 1 Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. Specifically, A. Environmental monitoring (EM) samples were documented in Logbooks as collected but were not actually taken. Specifically, on 02/19/2026 we inspected the Quality Control Pharma (QCP) Microbiology Laboratory. We inspected EM samples under incubation. We noted the following. 1. Plant injection line aseptically fills products for the U.S. market. Plant ISO 5 active air samples were documented as collected in Logbook LB/QCP6/26/005-01 from 08:06 to 10:44 on 02/16/2026 during [illegible] Injection Batch [illegible] (domestic market) scaling activity. According to the Logbook record, these samples were under 20-25°C incubation from 02/16/2026 to 02/19/2026. However, on 02/19/2026 no samples were found in the laboratory incubator. Your QCP personnel confirmed these samples were never collected. In addition, we reviewed Plant filling line (non-U.S.) EM records. Plant aseptically fills [illegible] products. On 02/19/2026, we reconciled Plant EM samples under incubation and found the following. 2. Prior to sterile [Batch] fill line assembly activity: i. Grade A active air samples were documented in Logbook LB/QCP9/26/001-01 as collected from 09:50 to 11:36 on 02/14/2026 from Plant LAF (8 locations) for Batch [illegible]. According to the Logbook record, these samples were under 30-35°C incubation from 02/17/2026 to 02/20/2026. However, on 02/19/2026 no sample plates were found in the laboratory incubator. Your QCP personnel confirmed these samples were never collected. Despite no samples being collected, on 02/17/2026 at the end of 20-25°C incubation, the result of "Nil" cfu was documented in the Logbook for each of the Grade A locations. ii. Grade B and Grade C active air samples were documented in Logbook LB/QCP9/25/002-01 as collected from 09:50 to 11:36 on 02/14/2026 from Plant EM filling and sealing areas for Batch [illegible]. According to the Logbook record, these samples were placed under 30-35°C incubation from 02/17/2026 to 02/20/2026. However, on 02/19/2026, no sample plates were found in the incubator. Your QCP personnel confirmed these samples were never collected. Despite no samples being collected, on 02/17/2026 at the end of 20-25°C incubation, the results of [illegible] cfu and "Nil" cfu were documented in the Logbook for each of the Grade B and C locations. 3. Prior to sterile Batch fill line assembly activity: i. Grade A active air samples were documented in Logbook LB/QCP9/26/001-01 as collected from 10:30 to 12:06 on 02/17/2026 from Plant LAF; locations for Batch [illegible]. According to the Logbook record, these samples were placed under 20-25°C incubation from 02/17/2026 to 02/21/2026. However, on 02/19/2026 no sample plates were found in the incubator. Your QCP personnel confirmed these samples were never collected. ii. Grade B active air samples were documented in Logbook LB/QCP9/25/002-01 as collected from 10:30 to 12:06 on 02/17/2026 from Plant EM filling and sealing areas for Batch [illegible]. According to the Logbook record, these samples were placed under 20-25°C incubation from 02/17/2026 to 02/21/2026. However, on 02/19/2026 no sample plates were found in the incubator. Your QCP personnel confirmed these samples were never collected. 4. Plant Grade A active air samples were documented in Logbook LB/QCP9/26/001-01 as collected from 12:17 to 13:20 on 02/12/2026 from LAF locations under static condition. According to the Logbook record, these samples were placed under 30-35°C incubation from 02/16/2026 to 02/19/2026. On 02/19/2026 we found one sample plate that showed desiccation. We observed only [illegible] out of a total [illegible] active air samples showed impaction patterns where the agar surface displayed small depressions when air was forced through a perforated lid onto each agar surface

      Shortened here; the PDF has the full text.

    2. Observation 2

      Inadequate aseptic process controls

      OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, A. While observing a mock aseptic fill on February 24, 2026, the following deficiencies were noted: 1. Operators were observed obstructing unidirectional HEPA-filtered air flow over the stopper bowl and bay vials while refilling the stopper bowl. 2. Operators observed obstructing unidirectional HEPA-filtered air flow by passing forceps over the work area and removing fallen vials from the area. 3. Operators observed obstructing unidirectional HEPA-filtered air flow while moving vials from the loading area to the loading area through the transfer. 4. Sterile forceps inside the holder had fallen over onto the bottom surface of the holder. The sterile forceps tips touched the surface and were placed back upright and used for subsequent interventions. 5. Approximately 5 NVPC alarms were encountered during the set up and filling operations. These alarms were triggered while manipulations were being made through the [port] in several areas of the filling line. The observed operator response was to acknowledge alarms and continue operations after particle counts returned to specification, without discarding potentially affected vials or initiating investigations. 6. The holder used to support the tank exhibited visible wear, cracking, and broken edges, presenting a potential source of particulate contamination in the Grade A environment. 7. Inadequate surface finishes were observed in multiple critical areas, including non-uniform sealant surrounding HEPA filter housings in the loading areas. These rough, irregular surfaces do not meet cleanable surface requirements and may harbor contamination. B. During the inspection, I (EL) reviewed aseptic process simulation (APS) / media fill (MF) conducted in Plant injection line. The following deficiencies were noted. 1. Your MF did not simulate the worst-case conditions relating to intervention frequency and duration. Specifically, you did not track or trend interventions that occurred during commercial manufacturing. Currently, intervention durations are not simulated. In addition, each intervention type is performed only once unless more is needed during MF regardless of worst-case conditions. 2. Your MF did not include the simulation of sealing activities. During MF, sealing operation was performed but activities i.e., sealing assembly, set-up, and interventions such as removal of jammed units were not simulated. The sealing operation represents a critical closing operation that must be evaluated for its potential impact on container closure integrity. C. During the inspection, I (EL) reviewed videos of airflow visualization studies (smoke studies) performed in 09/2023 for Plant injection line. The lack of adequate smoke coverage, turbulent airflow, or poor aseptic practice were observed. Examples include but are not limited to: 1. During [stopping] of two stoppers, the stopper bag was positioned over the stopper bowl, blocking HEPA-filtered first air to sterile stoppers. 2. During removal of fallen/broken vials from [area], the aseptic operator's hand and arm were positioned over open vials on the tray, blocking HEPA-filtered first air to sterile open vials. The impacted vials were not rejected. Your firm lacks a procedure defining requirements for rejecting vials when HEPA-filtered air is blocked. 3. During vial collection in the loading area and loading into the [container], the operator’s hand and arm were observed obstructing HEPA-filtered first air to vials. 4. During loading into the [machine], updrafts of airflow were observed between [components] containing vials. 5. During at-rest conditions, the airflow next to the equipment did not appear to adequately ensure HEPA-filtered air flows unidirectionally across the work zone to maintain a sterile environment. D. Your firm'

      Shortened here; the PDF has the full text.

    Show observation 3
    1. Observation 3

      Inadequate deviation management and follow-up

      OBSERVATION 3 Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, Your firm's deviation management system is inadequate and does not capture equipment issues that may affect product quality. Since March 2024, your firm has created approximately 50 service work orders in Plant for critical manufacturing equipment, including but not limited to [illegible]. Your firm did not initiate deviations for several of these equipment issues. According to firm management, deviations are only initiated for equipment malfunctions that occur during production that have an immediate product impact. Equipment issues are frequently identified and corrected solely through the service work order system and not evaluated through your deviation process. This practice is inadequate because: + Equipment malfunctions are not assessed for potential impact to product quality regardless of when they occur (set up, during production, etc.) + Issues are not tracked, trended, or investigated to identify root causes + Corrective and preventive actions (CAPAs) are not implemented or verified for effectiveness + Your firm cannot ensure that critical manufacturing equipment remains in a qualified and validated state Examples of service work orders with no corresponding deviations include the [illegible] leak rate test not maintaining and the filling machine [illegible] not working.

  2. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on May 29, 2026. Each one asked for a Form 483.

  • Inspection ending Feb 27, 2026OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 29, 2026FDA-FOIA-2026-5369Form 483· 1 of 2 sitesRecords released
    2. May 26, 2026FDA-FOIA-2026-5268Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3009510975, one row per refused product line.

1 refusal on 2025-07-02 · charged UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2025-07-02

    EPOETIN ALFA58LCY17

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-8571452-3/12/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2026-07-09

    FDA’s entry
    Reliance Life Sciences Private Limited · Ttc Area Of Midc, R - 282 Dhirubhai Ambani Life Sciences Centre; Thane Belapur Road, Navi Mumbai, Maharashtra INDIA
    FDA’s inspection record for FEI 3009510975
    Reliance Life Sciences Private Limited · Ttc Area Of Midc, R - 282 Dhirubhai Ambani Life Sciences Centre; Thane Belapur Road, Navi Mumbai, India

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    15 products

    • 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
    • 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
    • 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
    Show 12 more products
    • 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
    • 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Reliance Life Sciences Private LimitedD-U-N-S 650213072

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009510975 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009510975. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.