Shertech Pharmacy- Piedmont
1470 Hampton Plaza Dr, Kernersville, North Carolina, United States
FEI 3009042626
FDA has one inspection on file for Shertech Pharmacy- Piedmont in Kernersville, North Carolina (FEI 3009042626). It ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Production during adjacent construction
Your firm produced drugs while construction was underway in an adjacent area without adequate controls to prevent contamination of the production environment and product. Specifically, on 06/25/2019, there was on-going construction in the non-sterile drug manufacturing area which involved the displacement of ceiling tiles, exposing fiberglass ceiling insulation. I also observed the manipulation of drywall. On 06/27/2019, construction employees were observed sanding drywall and the smell of paint was pungent. The area of construction was immediately adjacent to the area where employees don garb and other protective apparel for use in sterile nuclear and non-nuclear manufacturing operations. The construction area was neither cordoned off nor physically separated from the rest of the pharmacy to protect the production environment within this area and the surrounding sterile manufacturing areas. Your firm continued to engage in sterile and non-sterile manufacturing operations while construction was underway. In addition, your firm did not conduct any environmental monitoring to verify that the environment was suitable for aseptic production during this construction period. Your firm produced and/or distributed products on 06/26/2019 and 06/27/2019 under those conditions. Among them were: •Rxil(D){6) Sincalidel.V. •Rx~(b)(6) Sodium Pertechnetate Tc99 b 4 (LEU) •R.xi(b)(6) HDP-Tc99m (LEU)(D) (4) •Rx1(b)(6) -HDP-Tc99m (LEU) 15 4 •Rx,(b)(6) - MDP-Tc99m<0>(4)(LEU) •Rx#c(b)(6) - Sestamibi - Tc99m (6) {4)(LEU) •Rx#.(b)(6) - Sestamibi - Tc99m b 4 (LEU) •Paraben Water for Injection (USP <51> Study •Methylcobalamin 1000 MCG/mL Injectable
- Observation 2
Poor personnel/material flow and garbing
Your facility was designed and/or operated in a way that permits poor flow of personnel and materials. Specifically, your facility does not have any physical barriers separating classified environments, with the exception of the ISO 5 laminar airflow hood used in sterile drug manufacturing operations. In addition, I observed employees and construction workers not properly garbed entering your firm's-controlled environments. Some examples are, but not limited to: • On 06/25/2019, I observed construction employees (not garbed) go through your firm's garbing area (identified as a "non-sterile ante area," but was not, however, classified by your contract certification entity) and enter your firm's restroom and return to the gowning area. • On 06/26/2019, I observed a pharmacist and a pharmacy tech (not garbed) traverse the Nuclear Room (ISO 7 classified) and proceed to the "non-sterile ante area" (not classified) where they donned non-sterile garb, then again traverse the Nuclear Room (ISO 7) where they began engaging in sterile drug manufacturing operations in their respective ISO 5 classified laminar airflow hoods. • On 06/27-28/2019, I observed administrative personnel (not garbed) working on computers located in the nuclear pharmacy (ISO-7 Classified).
Show observations 3 to 7
- Observation 3
Gloved contact without sanitizing
Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves. Specifically, on 06/26/2019, I observed personnel engaged in aseptic operations not sanitizing their gloved hands when moving from the Laminar Airflow Hoods (ISO 5 Classified Area) to an area of lesser air quality (ISO 7 Classified Area) and returning to the Laminar Airflow Hoods (ISO 5 Classified Area). Also, floor mats were observed on the floor at the ISO 5 working stations, the QC testing area and at support work areas in the ISO 7 nuclear pharmaceutical area. Neither the mats, nor the floor beneath the mats were observed to be cleaned and sanitized during the inspection. In addition, I observed product delivery personnel repeatedly entering your firm's sterile processing area from an unclassified area to check on product status without donning and/or changing their protective apparel (e.g. apron, foot covering, hair net, sleeve covering, face mask). According to your firm's distribution report, on 06/26/2019, your firm produced and distributed the following products: Product Name Lot Numbers HDP-Tc99m(LEU) (15)(4) K-20190626-003 M-20190626-003 The fifth I-131 Diagnostic Capsule Iodine-123 Capsule (200 uCi)[(D)-(4] 602190978 MAA-Tc99m (b)(4)(LEU) K-20190626-010 MAA-Tc99m (b)(4)(LEU) K-20190626-010 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20190626-004 MDP-Tc99m(b)(4)(LEU) K-20190626-001 Mebrofenin - Tc99m(15)(4)(LEU) K-20190626-006 Myoview - Tc99m(b)(4)(LEU) K-20190626-005 Sestamibi-Tc99m (b)(4)(LEU) K-20190626-008 Sestamibi-Tc99m (b)(4)(LEU) K-20190626-007 Sodium Pertechnetate Tc99m(b)(4)(LEU) E-20190626-004 Sodium Pertechnetate Tc99m(b)(4)(LEU) E-20190626-005 Sodium Pertechnetate Tc99m(b)(4)(LEU) E-20190626-003 Sodium Pertechnetate Tc99m(b)(4)(LEU) E-20190626-002 Sodium Pertechnetate Tc99m (b)(4)(LEU) E-20190625-004 Sulfur Colloid Tc-99m(b)(4)(LEU) K-20190626-009 Sulfur Colloid Tc-99m (b)(4)(LEU) K-20190626-011
- Observation 4
Leaving cleanroom without changing garb
Personnel engaged in aseptic processing were observed leaving and re-entering the cleanroom from non-classified areas without first replacing gowning apparel. Specifically, on 06/26/2019, I observed the pharmacist that had been engaged in sterile nuclear pharmaceutical manufacturing operations, leave the ISO 7 area containing the ISO 5 laminar airflow hood to prepare components for further processing. The pharmacist performed those procedures outside of the ISO 5 conditions while wearing the same gloves and protective apparel that he wore while performing sterile operations inside of the ISO 5 laminar airflow hood. In one instance, I observed the employee to retrieve supplies from a storage area (unclassified storage area) completely outside of the pharmacy's sterile processing then return to the ISO 5 processing laminar airflow hood. Upon returning to the sterile ISO 7 area the pharmacist's apparel came in direct contact with the (b)(4) that separated an unclassified area from the ISO 7 area. The (b)(4) separating the ISO 7 area from the unclassified area was not observed to be cleaned and sanitized during the inspection. The pharmacist changed his gloves but did not change his protective apparel (apron, foot covering, hair net, sleeve covering, face mask). Later during sterile nuclear pharmaceutical manufacturing, the pharmacist performed quality control testing on finished products in an ISO class 7 section of the pharmacy while wearing the same garb he had on while performing manufacturing operations. After receiving unacceptable results, the pharmacist returned to the area containing the ISO 5 laminar airflow hood to retrieve another sample but did not change his protective apparel (apron, foot covering, hair net, sleeve covering, face mask), prior to retrieving the sample. Also, following the completion of manufacture of the first round of radiopharmaceuticals, the pharmacist began preparation, and then manufactured more sterile radiopharmaceuticals. I did not observe the pharmacist to change his protective apparel during 06/26/2019 operations.
- Observation 5
No sporicidal use/contact time inadequate
Sporicidal agents were not used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area. Specifically, on 06/26/2019, I observed your firm's employees using (b)(4) and non-sterile (b)(4) within your sterile nuclear pharmacy ISO 5 Classified Laminar Airflow Hoods. Your employees did not allow for enough contact time after the application of (b)(4) prior to applying the non-sterile (b)(4). On 06/27/2019, I observed your procedures to prepare the work surfaces of your ISO 5 (b)(4) in your sterile non-nuclear pharmaceutical operations. You were using (b)(4) disinfectant (non-sterile) on those surfaces. Likewise, your employee did not allow for enough contact time after the application of the (b)(4) (non-sterile) disinfectant prior to applying the non-sterile (b)(4) on the surfaces of the ISO 5 laminar airflow hoods. A review of the labeling for this product does not support its sporicidal capabilities.
- Observation 6
Incomplete QC records and altered data
Your firm's records are deficient in that they do not include complete documentation of all data obtained during testing to provide assurances that your product meets release specifications. Specifically, A. Your firm's Audit Trails for Kit QC Controls obtained from your firm's (b)(4) software used in your firm's nuclear pharmacy, shows your pharmacists (b)(6) changed QC data from a failing result to a passing result twenty-nine (29) times without justification from 07/02/2018-07/02/2019. Examples include, but are not limited to: 1. During this FDA inspection, on 06/27/2019, your pharmacist (b)(6) changed failing results to passing results. However, the failing results occurred in 2018. According to your Pharmacist-in-Charge, this product has a half life of 6.02 hours and an expiration time of 12 hours. For example: i. MAG3-Mertiatide Tc99m (b)(4)(LEU), Lot # K-20180907-006, shows a failing result was entered on 09/07/2018. However, on 06/27/2019, the results were modified from 84.567% to 93.724%. ii. MAG3-Mertiatide Tc99m (b)(4)(LEU), Lot# K-20180719-001, shows a failing result was entered on 07/19/2018. However, on 06/27/2019, the results were modified from 82.928% to 91.119%. Your firm distributed some of these lots to end users. For example, but are not limited to: Product Name LotNumber Original QCResult Changed QCResult MAG3-MertiatideTc99m (b)(4)(LEU) K-20180719-001 82.928 91.119 MAG3-MertiatideTc99m (b)(4)(LEU) K-20180720-003 84.536 94.389 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180726-002 83.933 94.411 MAG3-MertiatideTc99m (b)(4)(LEU) K-20180731-003 83.477 96.213 MAG3-MertiatideTc99m (b)(4)(LEU) K-20180806-009 82.273 97.892 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180807-005 83.382 94.761 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180816-004 82.461 92.294 MAG3-MertiatideTc99m (b)(4)(LEU) K-20180817-005 83.084 94.796 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180820-008 87.583 92.442 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180828-002 82.299 96.415 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180829-009 87.181 90.771 MAG3-MertiatideTc99m (b)(4)(LEU) K-20180830-004 82.589 91.901 MAG3-MertiatideTc99m (b)(4)(LEU) K-20180904-007 88.636 98.486 MAG3-MertiatideTc99m (b)(4)(LEU) K-20180907-006 84.567 93.724 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180910-006 84.771 97.847 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20180910-012 96.652 82.018 97.02 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20181002-011 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20181003-012 83.75 98.157 MAG3-MertiatideTc99m (b)(4)(LEU) K-20181004-010 87.467 95.748 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20181015-008 89.267 91.186 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20181016-005 86.141 90.999 MAG3-MertiatideTc99m (b)(4)(LEU) K-20181017-008 88.128 93.656 MAG3-Mertiatide Tc99m(b)(4)(LEU) K-20181023-004 85.041 92.587 MAG3-Mertiatide Tc99m (b)(4)(LEU) K-20190204-013 89.359 93.254 MAG3-Mertiatide Tc99m(b)(4)(LEU) K-20190211-007 83.202 90.056 Sestamibi-Tc99m (b)(4)(LEU) K-20190429-012 87.969 90.886 Myoview- Tc99m (b)(4)(LEU) K-20190524-011 83.555 98.047 B. Your firm released failing product to end users. For example, but are not limited to: Product Name Finished Product LotNumber QC Result - % Tagging Failure (Acceptance Criteria=<><>) DTPA-Tc99m (b)(4) K-20180328-008 58.966 DTPA-Tc99m (b)(4) K-20180517-011 49.022 MAA-Tc99m (b)(4)(LEU) K-20180913-009 75.817 MAA-Tc99m (b)(4) K-20180809-007 43.091 Mebrofenin Tc99 K-20181216-001 2.234 Mebrofenin Tc99 K-20181011-009 43.315 MAG3-Mertiatide K-20181219-010 89.248 MAG3-Mertiatide K-20181009-003 89.008 MAG3-Mertiatide K-20181105-006 88.272 MAG3-Mertiatide K-20180823-013 87.731 MAG3-Mertiatide K-20181130-006 87.587 MAG3-Mertiatide K-20181003-010 82.37 C. A QC Report obtained from your firm's (b)(4) software system, dated 01/01/2018-07/01/2019, shows QC testing was not performed on approximately (b)(4) lots produced in your nuclear pharmacy prior to the distribution for the following products: Product Name CERETEC-Tc99m (b)(4) CERETEC-WBC DMSA-Tc99m (LEU) DTPA Tc99m (b)(4) HDP-Tc9
Shortened here; the PDF has the full text.
- Observation 7
Missing supplier/component documentation
Records associated with drug product components, containers, closures, labeling, production, control and distribution and within the retention period for such records, were not made readily available for authorized inspection. Specifically, your firm failed to provide complete documentation including but are not limited to: Certificate of Analysis (COA) for the receipt and approval of Octreoscan Cold Kits and Mertiatide Kits from your firm's suppliers. According to your (b)(4) Software System, Octreoscan Cold Kits were received from two different suppliers: (b)(4) and Mertiatide Kits were received from three different suppliers: (b)(4). For example, but are not limited to: A. On 01/18/2019, your firm received container #5645, consisting of (b)(4) vials of Mag3-Mertiatide Kit, Lot (b)(4), with the vendor listed (b)(4) and the manufacturer listed as (b)(4). Your firm does not have any documentation supporting this (b)(4) product came from (b)(4). Mag3-Mertiatide Kit, Lot (b)(4), was used in the production of at least (b)(4) lots of MAG3-Mertiatide Tc99m from this facility. B. On 02/22/2019, your firm received container #5711, consisting of (b)(4) vials of Mag3-Mertiatide Kit, Lot (b)(4), with the vendor listed as (b)(4) and the manufacturer listed as (b)(4). Your firm does not have any documentation supporting this (b)(4) product came from (b)(4). Mag3-Mertiatide Kit, Lot (b)(4) was used in the production of at least (b)(4) lots of MAG3-Mertiatide Tc99m from this facility. C. Your pharmacist in charge received an email from (b)(4) stating (b)(4) shipped (b)(4) vials of (b)(4) in 2019. However, your firm's Received Container Report, dated 01/01/2019-07/01/2019, documents your firm received (b)(4) vials of (b)(4) Mag3-Mertiatide Kit, Lot (b)(4). Your firm could not provide documentation as to where the additional vials originated. Mag3-Mertiatide Kit, (b)(4), was used in the production of lots of MAG3-Mertiatide Tc99m (b)(4) (LEU). D. Your pharmacist in charge received an email from (b)(4) stating (b)(4) has no records of shipment to your account in 2018. However, 1. On 05/10/2018, your firm received container #5106, consisting of (b)(4) vials of Mag3-Mertiatide Kit, Lot (b)(4), with the vendor and manufacturer listed as (b)(4). Mag3-Mertiatide Kit, Lot (b)(4) was used in the production of MAG3-Mertiatide Tc99m, Lot# K-20180510-004 and distributed from your facility. 2. On 05/14/2018, your firm received container #5114, consisting of (b)(4) of Mag3-Mertiatide Kit, Lot (b)(4) with the vendor and manufacturer listed as (b)(4). Mag3-Mertiatide Cold Kit, Lot (b)(4) was used in the production of MAG3-Mertiatide Tc99m, Lot# K-20180514-009 and distributed from your facility. 3. On 06/04/2018, your firm received container #5175, consisting of (b)(4) of Octreoscan Cold Kit, Lot (b)(4), with the vendor and manufacturer listed as (b)(4). Octreoscan Cold Kit, Lot (b)(4) was used in the production of Octreoscan In111 Lot #M-20180604-003 and distributed from your facility. E. Your firm's 2018 Received Container Report, documents (b)(4) as the manufacturer and (b)(4) as the vendor for the receipt of (b)(4) vials of Mag3-Mertiatide Kit. However, your firm could not provide documentation supporting (b)(4) is the manufacturer of this product. In addition, your firm's 2018 Received Container Report, documents (b)(4) as the vendor and the manufacture field is blank. For example, but are not limited to, on 12/24/2018 (b)(4) vials of Mag3-Mertiatide Kit (cold kit), lot (b)(4), were received by your Pharmacist-In-Charge (PIC), for shipping container #5599. This same lot, Mag3-Mertiatide Kit (cold kit), lot (b)(4), was involved with a complaint received for a gall bladder image expressing in a renal scan for MAG3-Mertiatide Tc99m (b)(4)(LEU). According to your PIC, the naming convention for the final product MAG3-Mertiatide Tc99m (b)(4) (LEU) indicates (b)(4). Your firm did not have any supporting documentation verifying (b)(4) this product. Mag3-Mertiat
Shortened here; the PDF has the full text.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009042626 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009042626. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.