Octapharma Plasma, Inc.
3342 Broadway Blvd Ste 110, Garland, Texas, United States
FEI 3008107480
FDA has 4 inspections on file for Octapharma Plasma, Inc. in Garland, Texas (FEI 3008107480), from 2013 to 2019. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 7 citations from this inspection. They are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2013–2019
- 0 OAI · 1 VAI · 3 NAI
- Inspections with 483 observations shown
- 1 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Oct 11, 2023
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Storage temperature for plasma for Injectable products
Failure to store plasma intended for manufacturing into injectable products at a temperature not warmer than -20 degrees Celsius.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection of blood and blood components for further manufacturing purposes were not always followed.
Unsuitable donation - release
Failure to prevent the release of unsuitable blood and blood components for further manufacturing.
Supplemental Test for HIV [Collecting Establishment]
Failure to perform further testing for HIV on the reactive donation, as required by the regulations.
Adverse Reaction- Reports of Investigations
Written reports of investigations of adverse reactions, including conclusions and follow up, are not prepared and maintained.
Show 2 more citations
RBC loss deferral
Failure to defer a donor from donating plasma by plasmapheresis after the donor experienced a cumulative blood loss in an 8 week period that could adversely affect donor health.
Donor Deferral - reentry
The method or process used to requalify deferred donors was not found acceptable for such purposes by FDA.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Oct 11, 2023. It asked for a Form 483.
Inspection ending May 9, 2019VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 11, 2023FDA-FOIA-2023-8938Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 4 inspections.
- 21 CFR 606.100Standard operating procedures1 of 1
- 21 CFR 606.170Adverse reaction file1 of 1
- 21 CFR 610.41Donor deferral1 of 1
- 21 CFR 610.46Human immunodeficiency virus (HIV) “lookback” requirements1 of 1
- 21 CFR 630.30Donation suitability requirements1 of 1
- 21 CFR 630.15Donor eligibility requirements specific to Whole Blood, Red Blood Cells and Plasma collected by apheresis1 of 1
- 21 CFR 640.69General requirements1 of 1
Other FEIs recorded as Octapharma Plasma, Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Octapharma Plasma, Inc.FEI 1053485Charlotte, North Carolina, United States
Last inspected 2025-11-06NAI
Octapharma Plasma, Inc.FEI 3014027617West Palm Beach, Florida, United States
Last inspected 2025-10-08NAI
Octapharma Plasma, Inc.FEI 1076406North Charleston, South Carolina, United States
Last inspected 2025-07-09NAI
Octapharma Plasma, Inc.FEI 3007539614South Bend, Indiana, United States
Last inspected 2025-05-15NAI
Octapharma Plasma, Inc.FEI 3012375604Forestville, Maryland, United States
Last inspected 2025-03-14NAI
Octapharma Plasma, Inc.FEI 3007198422Terre Haute, Indiana, United States
Last inspected 2024-12-20VAI
Octapharma Plasma, Inc.FEI 3006295572Lynchburg, Virginia, United States
Last inspected 2024-12-13NAI
Octapharma Plasma, Inc.FEI 3007960248Chesapeake, Virginia, United States
Last inspected 2024-12-12NAI
Octapharma Plasma, Inc.FEI 1035346Jacksonville, Florida, United States
Last inspected 2024-11-21NAI
Octapharma Plasma, Inc.FEI 3011502580Decatur, Georgia, United States
Last inspected 2024-10-24NAI
Not every site is listed: these are the most recently inspected sites found under this name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008107480 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008107480. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.