Skip to content

Zhejiang Hisun Pharmaceutical Co., Ltd.

46 Waisha Rd., Jiaojiang District, Taizhou, China

FEI 3007719313DUNS 654211754

Company: Zhejiang Hisun Pharmaceutical Co., Ltd. · Linked by exact D-U-N-S match (654211754) in FDA registration data

FDA has 12 inspections on file for Zhejiang Hisun Pharmaceutical Co., Ltd. in Taizhou, China (FEI 3007719313), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

The most recent OAI inspection ended on Mar 7, 2015. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, Zhejiang Hisun Pharmaceutical Co., Ltd. (D-U-N-S 654211754), has registered 2 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
12, 2009–2024
1 OAI · 7 VAI · 4 NAI
Inspections with 483 observations shown
2 of 12
Form 483s posted by FDA
↗
2 posted
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

12 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesPosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete laboratory metadata and audit trails

      Laboratory records do not always include relevant metadata in order ensure established procedures are followed. Specifically, during our review of historical (2012-2014) original chromatography (HPLC) data collected in 4 4 4 support oq b><> • AP! DMF~and fbH> IAPl DMFp,>< > , we found that the integrity of data collected and reported could not be fully verified: For example (this list is not exhaustive): A) For p>H4> t API 4 a) The audit trail for stability data collected at the 12 month timepoint for batch ~>< > J was not available for review. According to your analyst, the audit trail was not archived and cannot be retrieved. h) Data for the O and 24 month stability timepoints for batch p>><4> I were collected using stand-alone Agilent HPLC systems with no system audit trail or other controls enabled to ensure data integrity. B) For p>><4> •APl 4 a) Data for the O month stability timepoint for batch ~bH> I was collected using stand-alone Agilent HPLC system with no system audit trail or other control enabled to ensure data integrity.

    2. Observation 2

      Deficient cleaning and maintenance procedures

      Written procedures are deficient regarding the cleaning and maintenance of equipment. Specifically, A) During our review of your cleaning validation study performed for thd 1>>< > tablet press to be used in the manufacture of !1>><> I tablets, we found that there is no scientific rationale (e.g. risk assessment) justifying the ~ sampling points. Additionally, there are no specific instructions (e.g. diagrams, pictures) available to define where the swabbing wasto take place. For example, your validation report states that the ,<1>>1 > "inner surface" was sampled; however, there is no evidence available to define the sampling location in order to ensure that the worst-case location was sampled. B) Your firm uses purified water as the solvent during routine cleaning of ther>< > ) tablet press following the manufacture of fb><4> J tablets, however, there has been no scientific evaluation to justify the use of purified water and evaluate its effectiveness considering the API and excipients used during manufacturing. C) Your cleaning procedure document H5-SOP-5204 for cleaning of the i<1>><> tablet press lacks specific instructions regarding how to disassemble/reassemble the equipment, the temperature of purified water to be used, and the cleaning tools (e.g. brush) and actions to be used.

    Show observations 3 to 8
    1. Observation 3

      Inadequate monitoring of sample storage

      Storage conditions for samples retained for testing are not monitored appropriately. Specifically, your firm's stability chambers' routine monitoring is performed at the locations found to be the highest temperature and humidity during the qualification studies. These locations do not represent the worst-case locations (coldest/lowest humidity) within the chambers.

    2. Observation 4

      Records not completed contemporaneously

      Records are not completed contemporaneously. Specifically, during my inspection of your microbiology laboratory on 08/08/17, I observed your microbiologist preparing to load the purified water and CbH > plates into the incubator for samples collected and prepared earlier that day. However, the sample preparation worksheets for these samples were either partially completed or blank.

    3. Observation 5

      Incomplete microbial limit testing records

      Laboratory records do not include complete data derived from microbial limit testing to ensure established procedures are followed. Specifically, 4 ITablets 1<b> I. During our review of the microbial limits test method validation fodbH > m mg, we noted the following discrepancies: a) The wei_ght of product sample used is not documented. b) The initials and/or signature and date of the analyst are not documented on microbial test record sheets. c) There is no documentation to demonstrate when and who performed thd b><> I and tbH > transfer between incubators. 2. Our review of historical stability data fod bH4> J tablets ~:( mg, we noted the following discrepancies: a) The initials and/or signature and date of the analyst are not documented on the microbial test records sheet. b) There is no documentation to demonstrate when and who performed the 'CbH > transfer between incubators for batch #'s ~H> .(bH> 1 and ~bH> I [illegible]

    4. Observation 6

      Undocumented manufacturing process changes

      Changes to manufacturing processes are not fully documented. Specifically, your firm performed two "major" c,~rs to thdbH) AP] manufacturing process in 2016 documented under 4 VC-!b><> ~-1602 and vcr n > 1603. There was no risk assessment or other scientific evaluation documented to justify the actions taken to monitor the acceptability/effectiveness of these process changes.

    5. Observation 7

      Missing process validation data history

      Process validation studies do not contain a history of all relevant data. Specifically, during our review of your in-process control F > l data collected during the process validation study for p>><> IAPl performed in 2010, we found the following deficiencies: A) Original in-process electronic data is not available for review. B) During our review of the printed tt>>< > ! for in-process ~~rr n> , , ntified (6)14) (b)(4) what appears to be an i(llH > peak in the standard peak summary table at ~ However, 4 . (bH4> I - .si(bH4> your printed i(llH> traces are only available up to The presence of this akin the 4 remaining t,i(llH > _Je.g. samples) could not be determined. [illegible]

    6. Observation 8

      Finished API storage areas in disrepair

      The final API storage areas are not maintained in a good state of repair. Specifically, on August 9, 2017 during my walk-through of the finished API storage areas, I observed what appeared to be water leakage in room #'s 102, 104 and 105. rn> 1APl was stored in room 102, '(l>H > !APl was stored in room 104 and !b><> !APJ was stored in room 105. ----- .____..

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Data integrity: deleted/overwritten results

      OBSERVATION I Quality Control laboratory control procedures are not followed. Specifically, your firm received a Warning Letter from the FDA dated 12/31/15 regarding breaches in the integrity of analytical data generated in support of the registration, batch release, and stability of your API products. As part of your firm's response, you committed to and submitted the results of a "full-scale investigation" of historical data collected during the period 01/01/13 to 03/01/15 to determine if there are "any similar data integrity issues", as outlined on page 2 of your "Evaluation Report for HPLC Analytical Data in QC Lab" dated 01/24/16. Your conclusion submitted to the Agency found "no data related with product failures were identified during the full-scale investigation". However, our limited review of the electronic data and associated metadata for during this same time period during this current inspection identified numerous examples of data integrity issues that were not identified and investigated as part of your "full-scale investigation". Examples identified included the same categories as outlined in the previous FDA 483 dated 03/07/15: namely: 1. deletion and overwriting of data, and 2. running analyses without the audit trail enabled. Our limited spot-check review identified approximately 23 such instances, only 3 of which were included in your "full-scale investigation" report submitted to the Agency. Representative examples identified during this inspection and not submitted in your Evaluation Report are outlined below: (unknown batch number) (b)(4) 1. - An analyst (unknown) performed an analysis on 03/20/2014 with the audit trail function disabled. - An analyst performed processing of these chromatograms on 03/21/2014 starting at 8:21 with the audit trail enabled. (b)(4) (b)(4) 4 month stability batch [impurities] by HPLC - During the running sample set on 03/12/14, your analyst (b)(4) deleted/overwrote a total of 5 sample injections related to these stability sample aliquots: (b)(4) injected 11:36 (this injection result was deleted) (b)(4) injected 12:26 (this injection result was reported) (b)(4) injected 13:15 (this injection result was deleted) (b)(4) injected 13:37 (this injection result was deleted) (b)(4) injected 15:05 (this injection result was reported) (b)(4) injected 14:02 (this injection result was deleted) (b)(4) injected 15:29 (this injection result was reported) (b)(4) injected 14:26 (this injection result was deleted) (b)(4) injected 15:53 (this injection result was reported) (b)(4) (b)(4) batch #1 degradation study by HPLC - During the running sample set on 06/10/14, your analyst (b)(4) stopped the running chromatogram after approximately 8 minutes at 16:36. - The sample was re-injected at (b)(4) and the original result was deleted/overwritten.

    2. Observation 2

      Stability labeling unsupported by data

      OBSERVATION 2 Labeled storage conditions are not justified by stability studies. Specifically, an OOS result for impurities by HPLC was confirmed for [illegible] stability (12 months, batch # [illegible]) during the investigation OOS-FLUD-1501. The labeled expiration date and conditions for this batch are [illegible]. There is currently no stability data to support these label claims. Notably, following this confirmed stability failure your firm transferred samples of this batch from the retain samples storage [illegible] to the [illegible] stability chamber in order to support the label claim of NMT [illegible]. However, storage at [illegible] is not representative of the worst case label conditions.

  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  10. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  11. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  12. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007719313, one row per refused product line.

1 refusal on 2017-03-29 · charged DRUG GMPS on 1 · no FDA sample analysis

FDA firm profile
  • 2017-03-29

    ZERANOL (ANABOLIC)60KNS16

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Philadelphia District Office101-5371136-1/11/2

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Zhejiang Hisun Pharmaceutical Co., Ltd.D-U-N-S 654211754

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Zhejiang Hisun Pharmaceutical Co., Ltd. (D-U-N-S 654211754) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3007719313 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3007719313. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.