Skip to content

Westlab Pharmacy, Inc. dba Westlab Pharmacy

4410 Newberry Rd Ste A5, Gainesville, Florida, United States

FEI 3007426960

FDA has 2 inspections on file for Westlab Pharmacy, Inc. dba Westlab Pharmacy in Gainesville, Florida (FEI 3007426960), from 2018 to 2021. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Aug 15, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2018–2021
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Vermin observed in production area

      Vermin was observed in your production area. Specifically, on 9/27/21, a large dead insect was observed within the ceiling light fixture directly above your firm's ISO-5 Cleanroom. Additionally, a few similar large insects were also observed within the ceiling light fixtures within your ISO-8 Anteroom where sterile gowning is conducted.

    2. Observation 2

      Non-microbial contamination observed

      Non-microbial contamination was observed. Specifically, A. From 9/27-9/29/21, brown stains were observed in the ISO-5 laminar airflow hood. B. During the walk-thru of your firm's non-sterile [area], (6) (4), Serial (6) (4) was observed covered with clear tape which cannot [illegible]. Technician stated [illegible] replaces the tape. Drug products which include, but are [illegible], #09272021@76, BUD: 3/2/22 dispensed [illegible]. C. During the walk-thru of your firm's non-sterile [area], [illegible] between your [illegible] designated hazardous [illegible] of dust.

    Show observations 3 to 8
    1. Observation 3

      Environmental monitoring not performed

      Environmental monitoring was not performed. Specifically, environmental monitoring (viable/non-viable, surface and personnel monitoring) was not conducted during or directly after sterile compounding operations.

    2. Observation 4

      Inadequate media fill simulations

      Media fills were not performed that closely simulate appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, on 9/2/21 your firm produced 15 (4) of Oculostasis Ophthalmic eye drops, lot #09022021@30, BUD: 10/17/21 which incorporated the dispensing of sterile product within an opened sterile dropper container. Instead, [media fills] utilized syringes and sealed sterile vials which fails to pose a challenge to aseptic technique.

    3. Observation 5

      Aseptic technique blocked first-pass air

      Personnel were observed conducting aseptic manipulations that blocked the movement of first pass air around sterile product. Specifically, on 9/29/21, your firm's Pharmacy Technician [redacted] blocked the movement of first pass air in the hood while manipulating Trimix 30 mg/2 mg/20 mcg/mL 5 mL injectable, lot #09292021@40. In addition, [illegible] was observed to conduct aseptic [illegible] filter which creates turbulent airflow as also depicted [illegible].

    4. Observation 6

      Inadequate cleaning for hazardous drugs

      Hazardous drugs were produced without providing adequate cleaning of [equipment/personnel] to prevent cross-contamination. Specifically, on 9/27/21, your firm produced, but was not limited to, Progesterone 200 mg (qty: 90) Capsules, lot #09272021 (15 (4)) and Testosterone 250 mg [illegible] dispensed under (6) (4). Serial (1:5)(4) and failed to use a deactivating agent to clean the hood in between batches of hazardous drug products.

    5. Observation 7

      Unverified non-pharmaceutical component used

      Non-pharmaceutical [component] (not meeting specifications) was used as a component within non-sterile drug production. Specifically, your firm is utilizing the [illegible] to produce non-sterile drug products. Your firm's Pharmacy Technician stated that your firm does not conduct testing (chemistry or microbiology) to ensure the non-pharmaceutical [component] meets USP specifications.

    6. Observation 8

      Water source (sprinkler) in cleanroom

      A water source is present in the cleanroom where the ISO-5 area is located. Specifically, your firm has a fire sprinkler located in the ceiling/hood where sterile production is performed.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Cleanliness, ISO-classified areas

      The ISO 5 classified aseptic processing areas had difficult to clean equipment or surface.

    2. FDCA 501(a)(2)(A)

      Use of non-pharmaceutical grade components

      You used a non-pharmaceutical grade component in the formulation of a drug product.

    3. FDCA 501(a)(2)(A)

      Disinfecting and cleaning agents, ISO 5 area

      Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.

    4. FDCA 501(a)(2)(A)

      Actionable microbial contamination, ISO 5 area

      You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.

    5. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    Show 4 more citations
    1. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    2. FDCA 501(a)(2)(A)

      Exposure of personnel in aspectic processing

      Personnel engaged in aseptic processing were observed with exposed hands.

    3. FDCA 501(a)(2)(A)

      Location, ISO 5 classified area

      The ISO 5 classified aseptic processing area was located within a non-classified room (segregated production area).

    4. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the identification, sampling, testing, approval and rejection of components, drug product containers and closures.

Regulations FDA cited here

The 3 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3007426960 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3007426960. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.