Kv Pharmaceutical Inc
2280 Schuetz Rd, Saint Louis, Missouri, United States
FEI 3007259359
FDA has one inspection on file for Kv Pharmaceutical Inc in Saint Louis, Missouri (FEI 3007259359). It ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Jul 24, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2009
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit failures and QA oversight
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, the Quality Control/Quality Assurance (QC/QA) functions have failed as evidenced by the following examples and the remaining observations cited on the FDA 483. For example, a. After dissolution failures occurred with Metoprolol Succinate 25 mg ER Tablets manufactured with ER pellet lots with below target assay values, several lots of the ER pellets (#s 96671, 96856, 96857, 96858, 96859, 96860), with assay values below the target were blended off with ER pellet lots with assay values at or above the target value. There is no formal documentation or justification for the blend-off process. This blending off of sub par product was conducted in approximately (b) lots of bulk tablets from September until November 2008. This was performed at the instruction of upper management and acceptance by Quality Assurance. (b)(4) b. After dissolution problems were encountered with Metoprolol ER pellets due to high acetic acid values, (b)(4) a decision was made by upper management with no formal documentation or justification, to blend off lots which assayed above (b)(4) with lots assayed at or below (b)(4). Lot #121415 of (b)(4) had an acetic acid value of approximately (b)(4) and was used with lot #122572 (b)(4) in at least (b) lots of ER pellets (#s 98950-98954 and 101203-101214) in November of 2008. (4) c. The quality control unit has failed to implement adequate corrective and preventative action into the hundreds of complaints of leaking capsules received on PrimaCare One, Prenatal Multivitamin/Mineral Capsules. The firm continued distribution of this product despite continued complaints of leaking capsules as evidenced by the following. The investigation is ongoing and product is currently being reformulated. 2007 complaint statistics; over 350 complaints of leaking capsules for PrimaCare One, with 26 documented adverse event reports (ADEs); Correspondence from the manufacturing firm dated 02Jan2008 in which an "improvement plan" is addressed for the PrimaCare One manufacturing process; and by 2008 complaint statistics; over 630 complaints of leaking capsules with 21 documented ADEs. d. Rework by re-screening due to unacceptable particle size was performed in August 2007, without change control, QA approval and validation, on IR pellets lot #87843 (C-664). This pellet lot was used during the remainder of 2007 and early 2008 in the manufacture of (b)(4) Metoprolol Succinate 100 mg/200 mg tablet batches which were subsequently released. The batches included lot #'s (b)(4). Further, a pre-approval supplement was not pursued for this rework process nor was this rework process submitted in the Annual Report dated 05Jul2008. Notes from an upper management meeting indicate the re-screened product cannot be used for commercial sale until the pre-approval supplement is approved. e. The quality unit did not effectively review the packaging batch record prior to the release of Oxycodone 15 mg Tablets lot # 90330 to the market. This batch was packaged using bulk tablet lot #83391 which had been rejected when it failed the finished product specifications for assay. Awareness of the release of the failed batch was realized when the warehouse could not locate the failed lot of product for destruction on 29Jun2008. The packaging batch record for lot #90330 referenced the two different bulk tablet batches of Oxycodone 15 mg, lots #'s 91391 and 83391. However, only lot #83391 was used. Additionally, the packaging batch record contained the incorrect COA (for lot 91391); it did not contain the COA for lot #83391.
- Observation 2
Unvalidated manufacturing processes
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, for Metoprolol Succinate Extended Release (ER) tablets, Hydromorphone HCl Tablets, Morphine Sulfate ER Tablets, and prescription nutritional supplements, the process steps executed to accomplish manufacture have historically resulted in variable products of unreliable quality, different than the product results obtained from the designed, validated process. Metoprolol Succinate ER Tablets a. It does not appear the Metoprolol Succinate ER Tablets product line (25 mg, 50 mg, 100 mg, 200 mg) was developed in a scientifically sound manner with appropriate specifications and process controls. All strengths have historically resulted in drug product of variable quality when the designed processes are executed as evidenced by the high numbers of batch rejects, in-process rejects, out-of-specification (OOS) test results and non-conformance reports (NCRs) at all manufacturing stages. The OOS test reports included but were not limited to the following: Assay; Loss on Drying; Dissolution; Content Uniformity, and Particle Size. The NCRs included but were not limited to the following: Foreign Tablet; unapproved deviation; Speed Study; Failed AQL-broken tablet; Omission of IR Pellets; Expired ER pellets, Content Uniformity; Metal shaving found on Press; IR pellet Particle Size; Sample Prep error; and ER pellet particle size. b. There is insufficient evidence to support the release of Metoprolol Succinate 100 mg ER Tablets processed with active pharmaceutical ingredient (API), Metoprolol Succinate USP, which was different from that used in the designed process. Since your 05Aug2007 IR pellet validation study (07CRC-664(R7)PE-14-08) using the Mexican Intermediate of (b) Metoprolol Succinate in the production of 100 mg and 200 mg tablets, you have had approximately (b) NCRs relating to particle size. The particle size of post-validation lots of this API are smaller than the particle size (4) of the API used in the 2007 validation study. You continued to manufacture and distribute approximately (b) lots of these tablets until 17Oct2008, when you ceased production. The IR and ER pellet batches used in the tablet batches have sporadically failed particle size tests since that time. In fact, since 03Jul2008, 231 IR pellet batches were rejected for particle size problems. You have also released several batches of Metoprolol Succinate 100 mg ER Tablets manufactured using the API lots received with a changed, (b)(4) smaller particle size that had been received prior to 03Jul2008. These include batch #'s (b)(4) manufactured in July of 2008 to mid October 2008, using pellet lots that had included API lot #'s (b)(4). c. You failed to take appropriate corrective actions after investigational findings identified the root cause for dissolution failures of Metoprolol Succinate ER Tablets, 50 mg. During the 06Aug2008 investigation of NCRs 14969 and 14181, (b)(4) you identified excessive press speed to be the root cause of the dissolution failures for lot #'s 93394 and 93862. This data brings the validation study (08WP7036900 [RI]PV-07-01) under suspect, in which the press speed range is (b)(4). In addition, you continued to operate at press speeds (b)(4) and released approximately (b) lots of Metoprolol Succinate Tablets 50 mg from 06Aug2008 to the time of this inspection. d. Rework by re-screening due to unacceptable particle size was performed in August 2007, without change control, QA approval and validation, on IR pellets, lot # 87843 (C-664) used in the manufacture, release and distribution of the following Metoprolol 100 mg/200 mg tablet batches, lot #'s: (b)(4). Further, a pre-approval supplement was not pursued for this rework process nor was this rework process submitted in the Annual Report dated 05Jul2008. Notes from a
Shortened here; the PDF has the full text.
Show observations 3 to 5
- Observation 3
Incomplete investigation records
Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications. Specifically, a. There was no investigation into conflicting assay results between the release bead uniformity potency results for Metoprolol Succinate ER pellet batches, which were lower than target but within specification, and the results from a second subsequent test on a composite (retain) sample, performed under special request by the production department. There is no raw data for the composite sample results collected under this special request. These composite results were higher than the original bead uniformity results for (b)(4) C-759 pellet batches (lot #'s (b)(4)). (b)(4) batches of Metoprolol Succinate ER Tablets 23.75 mg, were manufactured in July and August of 2008, using the composite potency values from the pellet batches rather than the bead uniformity potency results. No evaluation has been performed of validation data to ensure 23.75 mg tablets will meet specification when blended with pellets with potency values below the target blend uniformity specification limit. b. No investigation to determine the root cause was performed for the following incidents: • Metoprolol Succinate ER pellet batch, lot # 98459 (47.5 mg tablets) which failed dissolution testing and was confirmed by DOS (# 005-08-SEP-012). NCR# 17634 was initiated 17Nov2008. • Potassium Chloride bead batch, lot # 99938 which was confirmed to be OOS (# 005-08-SEP-005) for time release dissolution. The results were outside of the proven acceptable range at hours (b)(4). NCR#16706 was initiated 29Sep2008. • Potassium Chloride (KCl) blend batches, lot #'s 99900 (005-08-OCT-017) and 99910 (005-08-OCT-045) which were confirmed OOS for timed release dissolution on 30Oct2008 and 04Nov2008, respectively. NCR#17397 was initiated for both lots on 05Nov2008. • Complaints of "black spots" and "moldy looking areas" were received for PreCare Premier prenatal vitamins; batch #'s 76051, 91544, 90006, 79697, 91545, 95301. At least eight (8) complaints of this nature were listed for lot 90006 alone, yet a letter was sent to a complainant stating this was an "isolated incident."
- Observation 4
Investigations lack conclusions/CAPAs
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, a. Corrective and preventive actions have not been carried out regarding NCR 12156 when Hydromorphone HCl Tablets 2 mg, lot 82575 failed the acceptance criteria for content uniformity in Dec 2007. The NCR determined the cause was segregation due to the use of the Auto Filler to transfer the powder blend into the press hopper. The report states (b)(4) (b)(4). The (b)(4) master record was not revised until July 2008 with the correction being implemented in September 2008. During that time numerous batches were manufactured using the AutoFiller; (b) of these remain within their expiry period. b. Corrective actions were not taken to rectify a systematic problem allowing compression prior to verification of acceptable blend uniformity data for products including Oxycodone HCl. QA approval of the blending process prior to compression is required. For example, Oxycodone HCl lot #96621 was blended on 23Jun2008 and compressed on 24Jun08. The batch failed blend uniformity on 08Jul2008. An investigation indicates the cause was sampling error yet no re-sample could be taken to confirm or refute the results because the batch had been compressed. c. No corrective or preventive action has been recommended concerning NCRs 14181 and 14969 which were initiated for lot #'s 93394 and 93862 of Metoprolol Succinate ER Tablets 47.5 mg which failed dissolution. The NCRs identify the root cause of the failures as "Excessive speed on the tablet press" despite press speed range specified in the master record of (b)(4). The batches continue to be manufactured at a press speed of (b). Approximately (b) batches have been made since this time. (4) d. Appropriate corrective and preventive actions were not taken when problems were encountered with cap torque during packaging of Prednisolone 5 mg/5 mL, lot #96179. The investigation did not extend to other affected product lots. CAPA #16409 opened 12Sep2008 stated the vendor was previously disqualified from producing any more closures due to significant quality issues. However, you continued to use this supplier's closures. • Personnel were not trained to document quality issues at the time of occurrence. Information in NCR 15949 initiated in response to this cap torque problem indicated that closure P5303 has always been problematic; yet, the problems have not been documented in the past. Additional monitoring of torques during packaging was not conducted for lots 10568, 10569, 1023471, 102372, 102373 and 102374 as instructed in CAPA 16409. e. After compressing Prenatal Rx1 Tablets lot # 95459 in May of 2008, compression tooling was found damaged with chips and broken keys. The cause was attributed to exceeding the allowable compression force of the tooling. The tooling is rated for (b) of compression force and the press was set at (b)(4). The compression force is a critical parameter but is not recorded in batch records. The master and batch production records have not been revised to specify the tooling rating and to require documenting the compression force. Corrective actions per CAPA 17035, to (b)(4) specification and to revise the MBR for input adjustment of Prednisolone USP based on potency for Prednisolone Syrup, USP, 5 mg/5 mL were not implemented. Stability data showed potency results trended downward through product expiry. g. No CAPA follow up or master batch record (MBR) revision has been documented concerning NCR 16469 opened on 16 Sep 2008 for Morphine Sulfate ER 100 mg tablets. The NCR captures excursion outside written procedures where bulk batch # 97343 was not compressed within the (b) limit as stated in the batch record. The NCR discussed that the limit was not established according to stability data and a CAPA, #17728, 24Nov2008, was opened to revise the hold time in the MBR between ble
Shortened here; the PDF has the full text.
- Observation 5
Investigations not extended to related batches
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy. Specifically, a. You failed to extend an investigation on oversized Potassium Chloride 10 mEq Capsules to products currently on the mark
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007259359 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007259359. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.