Shilpa Pharma Lifesciences Limited
Unit 2, Plot No.33,33A & 40 to 47, Raichur Industrial Growth Centre, Chicksugur, Raichur, India
FEI 3007197995DUNS 915076164
Company: SHILPA PHARMA LIFESCIENCES LIMITED · Linked by exact D-U-N-S match (855538259) in FDA registration data
FDA has 6 inspections on file for Shilpa Pharma Lifesciences Limited in Chicksugur, Raichur, India (FEI 3007197995), from 2013 to 2025. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on May 3, 2013. 3 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant, SHILPA PHARMA LIFESCIENCES LIMITED (D-U-N-S 855538259), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2013–2025
- 1 OAI · 3 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 6
- 1 posted 483 not matched to an inspection
- Warning letters
- None on file
- Import refusals
- 3 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
OOS investigations and power failures
Quality System OBSERVATION I There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. Out of Specification (OOS) Investigation Nos. OOS/004118/U-2 was initiated on 22 January 2018 for (bH> [illegible] batch no. [illegible] (manufactured [illegible]) stability batch at the 36-month stability time point (Long Term: 25 ± 2°C and 60 ± 5 % RH) and OOS/005/18/U-2 was initiated on 22 January 2018 for (bH> batch no. [illegible] stability batch at the 36-month stability time point (Long Term: 30 ± 2°C and 60 ± 5 % RH). The OOS failure during Related Substances (Method-IT) testing was initially categorized as (bH> [illegible] which exceeded the specification limit of NMT (bH> [illegible] %) for long term and (bH> [illegible] for intermediate condition and any unspecified impurity which exceeded the specification limit of NMT (bH> [illegible] % for long-term and intermediate conditions. The product has a five-year retest date/expiry (60 months). No assignable root cause was identified during (bH> of the investigation. Other deficiencies with the investigation include, but are not limited to: • Step (bH>) Phase (4) Investigation of SOP# SOP/QA/GEN/003/12 (Procedure for Handling and Investigating Out of Specification (OOS)) states Phase 1 investigation shall be carried out with team members consist of cross functional departments (Production, QC, QA, Research & Development, and Technology Transfer) and the investigation should be focus on review of Batch processing Records, Batch Cleaning Records, and other relevant documents which could be supportive of the investigation. The review of these records shall also be extended to pre and post batches, of manufacturing and distribution records. The firm failed to assemble a cross functional team to review Batch processing Records, Batch Cleaning Records, and other relevant documents records • Retesting of sample was [illegible] differences between conclusions. • You invalidated the initial OOS results and accepted the average results by [illegible] analysts. • You attributed the root cause identification to probability of contamination of diluent. As per preventive action, the SOP for good chromatographic practices (SOP/U-2/QC/GEN/010) was revised with incorporation of procedure for precaution during diluent preparation (SOP/U-2/QC/GEN/010/10). It was not discussed in the investigation report. B. During the walkthrough on 24 July 2019, three power failures occurred within the facility during a 15-minute interval and a back-up generator did not resume power. Additionally, while reviewing audit trails for two stability chambers (#SML2/QC/HC/005 and #SML2/QC/HC/001) it was noted that the facility frequently loses power, sometimes for over 8 hours. The firm has not maintained any records for power failures that occurred within the manufacturing areas and the QC lab, and has not conducted any investigation or assessment regarding the impact of the power failures to in-process product, QC Laboratory equipment calibration and on-going testing. In addition, there is no procedure to handle power failures in the laboratories and SOP#SOP/U-2/ENG/GEN/053/02 (Handling of Power Failure, Effective Date 29 May 2019) does not extend to conducting an investigation to demonstrate that an assessment was made to on-going manufacturing operations and laboratory testing operations at the facility to determine if there is any impact.
- Observation 2
Missing manufacturing equipment
Facilities & Equipment System OBSERVATION2 Equipment used in the manufacture of intermediates and APIs is not present within the facility. Specifically, (bH> of the (b) pieces of equipment used to manufacture (b) of the submission batches for API (b)(4) (b)(4) (b)(4) used in [illegible] capsules were not present in the facility. At the time of the inspection the below pieces of equipment were already discarded based on a change control from 02/2019. No documentation or assessment of what replacement equipment will be used to make this API was performed until the second day (23 July 2019) of the inspection. In addition, no notification of these changes was sent to the agency, the existing process flowchart for the product was not updated, and there is no documentation substantiating the decommission of the equipment. Equipment Name Capacity Material of Construction Equipment ID# [illegible]
Show observations 3 to 5
- Observation 3
Cleaning/maintenance and facility issues
OBSERVATION3 Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the API finished materials. Specifically, The following pieces of equipment used to manufacture (bH> an API were observed unmaintained during facility walkthroughs. All equipment noted below is non-dedicated and was in a clean state during my visual observation. A. Your performed clean hold time study in 2016 for the equipment used for the manufacturing of APIs in different production blocks is deficient and you did not follow the established protocols. (bH> was being manufactured in production (bH>) and was moved to (bH>) in June 2019 due to increase [illegible] size. Clean Holding Time Study Protocol # PCTQA/CHS/001 states in Step (bH>) "MB Department personnel shall collect the cleaning holding time study samples on the (bH>)". In addition, it states in Step (bH>) "If any deviations are noticed while conducting the validation, all those deviations, investigation details and corrective actions taken shall be documented in clean holding time study summary report." You reported in the Summary report (#RPT/QA/CHS/001) that the cleaning holding time study was stopped after (bH>) analysis due to exceeded results observed in TAMC analysis and you did not initiate a deviation for not continuing the study to (bH>). You added new products to the facility (bH>) since the last cleaning hold time study and you have not performed another cleaning hold time and/or assessment to ensure the equipment can remain clean for (bH>). B. Your performed dirty hold time study in 2016 for some of the production equipment in Block (bH>) is deficient and you did not follow the established protocols. Some of the equipment listed in the study was used for manufacturing (bH>) submission batches prior to being removed and replaced by new equipment. Dirty Holding Time Study Protocol #PC/QA/OHS [illegible] states in Step (bH>) (bH>) is sparingly soluble in (bH>) as per solubility criteria and this product was considered for dirty hold time study as worst case among the below mentioned 1 products. However there are three other products that are hardly sparingly soluble in (bH>) and you did not explain how you chose the worst case scenario. You added new products to the facility (bH>) since the last dirty hold time study and you have not performed another dirty hold time and/or assessment of how these products compare to (bH>). C. Peeling paint was observed above the (b>14) opening of (bH>) (bH>) during the walkthrough on 22 July 2019, which was used for the submission batches (bH>) and is projected to be used for commercial operations or the manufacturing of batches (bH>). D. Presence of holes and heavy marks were observed inside (bH>02 located in Block (bH>) which was used for the submission batches (bH>) and is projected to be used for commercial operations or the manufacturing of (bH>) batches. In addition, the ceiling area above the (bH>) is not finished. E. Presence of cracks were observed on the walls above the opening of (bH>) located in Room # (bH>) on 22 July 2019, which was used for the submission batches (bH>) and is projected to be used for commercial operations or the manufacturing of batches. F. A bolt was observed underneath (#AM) (bH>) old during the walkthrough of Block- on 22 July 2019, which is used for the manufacturing of (bH>). The firm was unable to identify where this came from.
- Observation 4
Computer system validation/audit trail issues
Laboratory Control System OBSERVATION4 Appropriate controls are not exercised over computers or correlated systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. The data acquisition software (Newtronic ICDAS version 1.2), which is used for monitoring the storage conditions (temperature and relative humidity) for the stability chambers has not been validated and has been in use since 2009. The stability chambers are used to store (bH>) (submission stability batches) and (bH>) (commercial) finished API materials for on-going stability studies for U.S. marketed products. a. A change control was not processed for the installation of the software and the equipment was released for use. b. Validation Master Plan # VMP/SML-2/001 Rev.00 did not address computerized systems and software used by the facility. B. The audit trail for the Newtronic ICDAS version 1.2 system used for Stability Chamber #SML2/QC/HC/005 (used for storing stability samples for (bH>) and Chamber #SML2/QC/HC/001 (used for storing stability samples for (bH>)) recorded several encountered power failures from 01/01/2016 to date which has not been investigated by the Quality Control Unit to determine the impact on the samples. In some instances, the power failures have lasted 9 hours. In addition, there is no SOP for the review of these audit trails. The stability chambers are used to store (bH>) and/or (bH>) finished API materials for on-going stability studies for U.S. marketed products.
- Observation 5
Instrument calibration and verification deficiencies
OBSERVATION 5 The calibration of instruments is not done at suitable intervals [in accordance with an established written program] [with provisions for remedial action in the event accuracy and/or precision limits are not met]. Specifically, A. You have not performed a verification of the FT-IR (ID# SML2/QC/IR/001) prior to each use per Step (bH>) of SOP# SOP/U-2/QC/OPR/002/06 (Operation and Calibration Procedure for FT-IR, Effective Date 24 November 2017) where it states, "Instrument verification is the procedure of demonstrating that spectrum IQ instrument is functioning correctly." In addition, you do not maintain a logbook for the verification of the equipment prior to use. The equipment was utilized for testing API Batch# JV-006/18 which was manufactured in July 2018 with August 2019 retest date used in capsules. B. Step (bH>) and (bH>) of SOP# SOP/ARD/OPR/006/06 (Operation and Calibration Procedure for X-Ray Diffractometer, Effective Date 14 March 2019) allow the analyst to turn off and turn on the equipment. In addition, when the equipment is turned on and off, it is not documented in a document and no system suitability is performed to assure that the equipment is working as intended based on its qualification parameters. This equipment is used for testing (bH>) finished API materials for release testing and was used for testing (bH>) batch # (bH>) - IVT006/18.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007197995, one row per refused product line.
3 refusals from 2018-11-29 to 2023-02-09 · charged UNAPPROVED on 3 · no FDA sample analysis
FDA firm profile- 2023-02-09
INHIBITOR (GROWTH FACTOR) N.E.C.60YIY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of West Coast ImportsW69-5020849-7/21/1
- 2023-02-09
INHIBITOR (GROWTH FACTOR) N.E.C.60YIY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of West Coast ImportsW69-5020849-7/11/1
- 2018-11-29
ANTI-NEOPLASTIC N.E.C.62ICZ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-6353502-3/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- SHILPA PHARMA LIFESCIENCES LIMITEDD-U-N-S 855538259
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names SHILPA PHARMA LIFESCIENCES LIMITED (D-U-N-S 855538259) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- SHILPA PHARMA LIFESCIENCES LIMITEDDeosugur, India · FEI 30255609031 inspection1latestMar 7, 2025VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3007197995 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3007197995. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.