Aarti Drugs Limited
Plot No. E-22, M.I.D.C., Tarapur, Palghar, India
FEI 3006418686DUNS 650453124
FDA has 4 inspections on file for Aarti Drugs Limited in Palghar, India (FEI 3006418686), from 2012 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Dec 8, 2017. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant is AARTI DRUGS LTD (D-U-N-S 650226046).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2012–2024
- 3 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 4
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Oct 28, 2024
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate deviation/OOS investigations
Written procedures is not established and followed for investigating critical deviations or the failure of a batch of intermediate or API to meet specifications. The investigation is not extended to other batches that may have been associated with the specific failure or deviation. Specifically, Market complaint (b)(illegible) A. On 8/12/2022, you received a market complaint CPL/22005 for presence of foreign particle during the analysis of Appearance of solution test. The market complaint was (b)(illegible) for batches (Table 1). You confirmed the presence of (b)(illegible) foreign particles by inspecting the retain samples of at least (b)(illegible). Through the investigation, you (b)(4) (b)(1) (b)(illegible) concluded that the root cause is the (b)(illegible) of the (b)(illegible). The nature of (b)(4) (b)(illegible) and nature (of the API) caused the (b)(illegible) of the API at the surface of (b)(illegible). This (b)(illegible) material looks like (b)(illegible) foreign particle in (b)(illegible). Table 1. Batches of (b)(illegible) implicated with (b)(illegible) You implemented CAPA No. CAPN23006 on 2/8/2023 and reworked (Corrective action) the batches and applied (Preventive action) on the (b)(illegible) surface of the (b)(illegible). Your investigation is deficient for multiple reasons including but not limited to: • Your sampling procedure for analyzing the (b)(illegible) impurity has no assurance that the (b)(illegible) particles were part of the sample. The experiment suggests that you tested the API (b)(illegible) which are not necessarily foreign particle. • You did not extend the investigation to other batches of APIs that were manufactured in the same equipment, (b)(illegible) during the time period that covers the manufacturing dates of the implicated batches. The implicated batches were manufactured between (b)(illegible) and (b)(illegible) (b)(illegible). Table 1 entries: You manufactured at least (b)(illegible) additional batches amounting to (b)(illegible) of (b)(illegible) between (b)(illegible) and (b)(illegible) that were not part of your investigation. • You reworked (not reprocessed) the above implicated batches and at least (b)(illegible) reworked batches (b)(illegible) failed USP specifications for (b)(illegible) impurity (Specification NMT (b)(illegible)). You retested these batches under (b)(illegible) specification and shipped to the local market and at least one of the (b)(illegible) batches (Batch No (b)(illegible)) was shipped to Export market (Morocco). Your procedure Reprocessing and Rework of Intermediate and Finished Product SOP No. 1049 Rev 7 (Effective date 1/29/2023) does not allow shipping of reworked batch to Export market. B. On 1/26/2022 you recorded OOS result OOS (b)(illegible) 2/02 for (b)(illegible) for Appearance of solution test. This OOS result was recorded for Batch No (b)(illegible). Your investigation concluded that the probable root cause was due to improper (b)(illegible) (b)(illegible) during the (b)(illegible) operation. You implemented CAPA No. CAPN22007 and reprocessed the batch and included a foot note in the batch record (b)(illegible). Your (b)(illegible) Head (b)(illegible) could not explain how the operator will determine that (b)(illegible). Review of the batch manufacturing record suggested that you (b)(illegible) the failed batch (b)(illegible) (b)(illegible). C. On 6/19/2022 you recorded OOS result OOS (b)(illegible) 22/07 for (b)(illegible) for Assay by HPLC method. The OOS result was reported for Batch No. (b)(illegible) (Mfg. date June 2022 Expiry date (b)(illegible)). This batch was analyzed along with two other batches in the same sequence for Related Substances (RS) and Assay by HPLC method. All the three batches passed the RS test and only one batch, Batch No. (b)(illegible) failed for the Assay. The tested assay result for the failed batch was (b)(illegible) against the Specification (b)(illegible). Phase Ia investigation did not reveal any obvious erro
Shortened here; the PDF has the full text.
- Observation 2
Inadequate analytical method validation
Test procedures is not scientifically sound and appropriate to ensure that raw materials, intermediates, and APIs, conform to established standards of quality and/or purity. Specifically, A. You use in-house test method for the analysis of Related Substances of (b)(illegible) by HPLC. A review of the corresponding Analytical Method Validation Report No. MVR/Rsr-(b)(illegible) (Effective date 12/25/2012) confirmed that the method is not validated for impurities. You use this in-house test method to release the (b)(illegible) or the manufacturing of (b)(illegible). B. You use in-house test method for Assay of (b)(illegible) by HPLC. The test method was validated at a contract laboratory (b)(illegible) then transferred to your laboratory. The method validation report AMVR-009 (Effective date 7/18/2018) confirmed (b)(illegible) use of three batches of (b)(illegible); however, your method verification/transfer Report No. AMVR/Assay (b)(illegible) (Effective date 8/6/2018) (b)(illegible) confirmed use of two different batches of (b)(illegible). Your procedure, Transfer of Analytical Method SOP No. 1067 Rev 02 (Effective date 1/29/2023) requires testing of the same sample for both the sites, contract lab and the (receiving) firm. C. You use in-house test method for Assay of (b)(illegible) USP by HPLC. The test method was validated at a contract laboratory as per the Report No. 14113/05112016/7 (Effective date 11/5/2016). You did not perform a method transfer as per your procedure, SOP 1067 Rev 02 (Effective date 1/29/2023). You use the above method to routinely test and release the API, USP. D. You use in-house test methods for Related Substance (RS) and Assay for (b)(illegible) USP. These methods were validated at a contract laboratory (b)(illegible) and documented in Validation Report Nos. 22289/280215/08, Effective date 2/28/2015 (Assay) and 10698/300315/21, Effective date 3/30/2015 (RS). On 9/19/2024, you stated that the firm has conducted the method transfer and the corresponding report was documented in Method Transfer Report and Protocol of (b)(illegible). According to your binder, the document was stored in Rack-(G4/5) under File No. 8/13. On 9/19/2023, you were unable to locate the document in your document repository location and were unable to share the report during the course of inspection. E. There is no method validation established for growth promotion test of microbiological media. There are no critical steps and parameters identified for this process such as the time limits (b)(illegible) parameter during sterilization and (b)(illegible) of the (b)(illegible). There is no assurance of the sterility of the (b)(illegible) without establishment and validation of the timeframes. The SOP 2004 titled "For Procure, Receipt and Maintenance Microbial Culture" also failed to provide any defined timeframes during these critical steps.
Show observations 3 to 7
- Observation 3
Non–stability-indicating forced degradation
You assign the storage conditions and retest or expiry dates of the APIs using test procedures that are not stability indicating. Specifically, A. Your protocol for forced degradation study of (b)(illegible). Document No. AD/FDP/2020/005-09 (Effective date 12/16/2020) stated degradation limit to be (b)(illegible). However, the corresponding report, Document No. AD/FDR/2020/005-00 (Effective date 2/8/2021) confirmed no degradation such that the subjected API (under all the forced conditions) met the API release specifications. B. Your protocol for forced degradation study of (b)(illegible). Document No. FDSP-(b)(illegible)-004/2023 Version 00 (Effective date 5/10/2023) has no degradation limit established and the corresponding report, Document No. FDSR-(b)(illegible)-004/2023 Version 00 (Effective date 6/7/2023) confirmed no degradation such that the subjected API (under all the forced conditions) met the API release specifications. C. Your protocol for forced degradation study of (b)(illegible). Document No. (b)(illegible) FDS/001 (Effective date 10/5/2006) stated (b)(illegible) must show some degradation. However, the corresponding report, Report of Forced Degradation Study of (b)(illegible) (Effective date 11/9/2006) confirmed no degradation such that the subjected API (under all the forced conditions) met the API release specifications. You concluded the report with a statement, "method followed for forced degradation study is stability indication". D. Your protocol for forced degradation study of (b)(illegible) USP, Document No. (b)(illegible) 302 (Effective date 2/3/2015) stated degradation limit to be (b)(illegible). However, the corresponding report, Document No. 22290/040315/11 (Effective date 3/4/2015) confirmed no degradation such that the subjected API (under all the forced conditions) met the API release specifications. Your Quality Control department head (b)(illegible) stated that the purpose of the forced degradation study is to evaluate the inherent stability of API under the forced conditions. He further stated that all the above forced degradation studies confirmed that the corresponding APIs are stable under the forced degradation conditions.
- Observation 4
Insufficient cleaning validation/procedures
Written procedures are not established for cleaning of equipment and its subsequent release for use in the manufacture of intermediates and APIs. Specifically, Your firm has not established adequate cleaning validation for your equipment located in Plant I and Plant [illegible] used in the production of the APIs for the U.S. market. There is no sufficient documentation to support your cleaning method and choice of reagents for your API products. There is also no procedure on how to determine the location of your swabbing and justification for your hard to clean areas selected. For example, (b)(illegible) D # 1 (b)(illegible) 2101 has only a single swabbing location at (b)(illegible) and your (b)(illegible) D# (b)(illegible) 01 have only a single swabbing location at the (b)(illegible) but no rationale to support these decisions. In addition, there is also no dirty hold time (DHT) and clean hold time (CHT) studies established for your equipment.
- Observation 5
Quality unit responsibilities and follow-up lacking
Responsibilities and procedures for quality units are not in writing and/or followed to ensure the API and intermediates manufactured at your facility are in compliance with CGMP. Specifically, A. Your firm failed to provide a comprehensive assessment and remediation plan for your deviation reports DEV-24004, DEV24001 and DEV-24002 to ensure effectiveness. There was no corrective action plan established for DEV-24001 and DEV-24002 and the corrective action plan established for DEV-24004 did not adequate to address the deficiencies. (b)(illegible) B. Your firm changed from predominantly (b)(illegible) plates to now exclusively (b)(illegible) plates. There is no documentation of a change control conducted to show adequate implementation and risk assessment of this change. The firm's current SOP 2025 titled "Cleaning of Glassware in Microbiology Laboratory" is the only documentation that has any reference to the use of (b)(illegible) plates in the context of how to clean the plate. C. Your firm fails to have an adequate tracking system in place to ensure sample traceability in each of the laboratory. There is an initial registration completed upon receival into QC sample storage room. However, after the initial registration there is no sample logbooks maintained by any of the laboratories to provide traceability of the samples and their quantities received or removed from the laboratories. D. Your firm does schedule and monitor training throughout (b)(illegible); however, the training provided to your firm is insufficient. There are several incidents where activities at the facility are inadequately completed despite training given. For example, your firm has had to retrain several personnel on the same topic due to inadequate completion of an activity, even though all personnel had recently received their required training on the topic. E.g., On 7/29/2023, you recorded laboratory incidence LE-07-23-020 when your employee (b)(illegible) from Intermediate Manufacturing failed to follow procedure to correctly use Electronic Laboratory Notebook (ELN). On 8/9/2023 you recorded another laboratory incidence, LE-09-23-004 for the same issue when your employee from HPLC department (b)(illegible) failed to follow the procedure to correctly use ELN. This confirms that your training is not effective. E. Your procedure, Reprocessing and Rework of Intermediate and Finished Product SOP No. 1049 Rev 7 (Effective date 1/29/2023) has provision for shipping the reworked batches only after obtaining the stability data for (b)(illegible). You shipped multiple batches of reworked APIs before completing the required accelerated and/or long-term stability data. Batches of reworked APIs that were released/shipped without (b)(illegible) of accelerated and/or long-term stability data including but not limited to; (b)(illegible) API Batch No's (b)(illegible) (Mfg. date December 2023, Shipped on (b)(illegible)) and (b)(illegible) (Mfg. date December 2023, shipped on (b)(illegible)). Both batches were manufactured from reworked parent batches. F. Your procedure, Reprocessing and Rework of Intermediate and Finished Product SOP No. 1049 Rev 7 (Effective date 1/29/2023) has provision for not shipping the reworked batches to Export market. You shipped multiple batches of reworked APIs to Export market. E.g., (b)(illegible) API Batch No's (b)(illegible) shipped to (b)(illegible) (Barcelona) and (b)(illegible) shipped to Morocco. G. Your procedure, Investigation and CAPA SOP No. 1037 Rev 15 (Effective date 6/29/2022) lacks procedure for the Impact Assessment such that you failed to investigate at least (b)(illegible) batches, amounting to (b)(illegible) of (b)(illegible). These batches were manufactured along with (b)(illegible) other batches of (b)(illegible) API that were implicated with (b)(illegible) foreign particles as per Market Complaint, CPL/22005.
- Observation 6
Ineffective internal audit program
Your internal audit is not effective to verify compliance with the principles of CGMP for APIs. Specifically, A. Your firm's internal audit is not robust and are all preannounced audits based on a predefined checklist that is included in SOP 1017 titled "For Internal Quality Audit". The selected auditors do not have any defined qualification to be selected as an auditor besides the completion of a general internal audit training course. There is no assurance that the auditors selected are adequate to conduct the assessment and that the internal audits produce effective results. B. The Quality Unit conducts a "QA (b)(illegible) Vigilance Round Observation" activity of the facility (b)(illegible) (b)(illegible). These reports are reviewed and replete by the Quality unit as part of their internal assessment. Neither of these quality activities; the (b)(illegible) vigilance reports, or the (b)(illegible) trending, have an established written procedures on how Quality is to properly conduct and evaluate their findings.
- Observation 7
Missing shipped/reworked batch records
Records associated with the API distribution were not readily available for inspection. You submitted list of APIs that were manufactured and shipped during the years 2022, 2023 and 2024. During the course of inspection and document reviews, it was discovered that multiple API batches were missing from the submitted list. Specifically, A. On 9/15/2024 you submitted a list of Reprocess and Reworked APIs that suggested no (b)(illegible) batches were Reworked and/or Reprocessed in 2022 and 2023. However, your Market Complaint # CPL/22005 suggested that multiple batches of (b)(illegible) were returned (Table 1). These batches were then reworked and distributed to the local as well as Export market. Your Site Head (b)(illegible) acknowledged the missing data from the shared API list and promised to provide updated list. B. On 9/19/2024, during the review of OOS result OOS/ OOS (b)(illegible) 22/07 for (b)(illegible) Assay by HPLC method, I noted that the corresponding Batch No. (b)(illegible) (Mfg. date June 2022 Expiry date (b)(illegible)) was missing from the initial list submitted by the firm and from the updated list "Dispatched Detail of Reprocess Batches" shared by the firm on 9/16/2024. Upon review of the Logbook Issuance Register for 2022, I noted the Batch No. (b)(illegible) was recorded on Page 023 and the batch was shipped to Export market. I also found at least (b)(illegible) batches with (b)(illegible) suffix were recorded in the Logbook Issuance Register. Your QA Executive (b)(illegible) stated that a suffix in the batch number indicates (b)(illegible). Again you stated that during the list compilation, the (b)(illegible) batches were missed out.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Oct 28, 2024. It asked for a Form 483.
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Oct 28, 2024FDA-FOIA-2024-9554Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- AARTI DRUGS LTDD-U-N-S 650226046
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006418686 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006418686. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.