Ballard Plaza Pharmacy I, Inc.
1801 NW Market St Ste 104, Seattle, Washington, United States
FEI 3006317860
FDA has one inspection on file for Ballard Plaza Pharmacy I, Inc. in Seattle, Washington (FEI 3006317860). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Jul 21, 2016 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2016
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Cleaning and disinfecting deficiencies
OBSERVATION 1 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting to produce aseptic conditions. Specifically, on April 25, 2016 during the production (Epinephrine-Hyaluronidase) 3.52 mg-9.38 mg-9.4 u/mL. A) A piece of thin, wood paneling was observed to be the r (b)(4) ISO 5 (b)(4) laminar flow hood fibrous material along the length of the work surface. B) non-sterile wipes were used to clean and wipe down ISO 8 anteroom. C) Apparent soiled material was observed on the metal grate covering the pre-filter r (b)(4) ISO 5 LFH. D) Apparent rust was observed on the following parts: wire basket; the wheel casters; and the screw heads connecting the legs. E) Apparent soiled material was observed on the handset surface. F) Apparent residue was observed on the classified area sides of the ISO 7 clean room. G) An approximately eight inch crack was observed between the ISO 8 anteroom and ISO 7 clean room.
- Observation 2
Sterilization process validation lacking
OBSERVATION 2 Procedures designed to prevent microbiological contamination include adequate validation of the sterilization process. Specifically. A) No [(b)(4)] bioburden limits have been established in order [to determine] capability of the r (b)(4). For example, (b)(4): 1) The [(b)(4)] Unit Lot # (b)(4) Block Solution (Bupivicaine-Lidocaine and Epinephrine-Hyaluronidase) 3.52 mg-9.38 mg-9.4 u/mL, lot number 04252016@1. 2) The [(b)(4)] Unit, Lot # (b)(4) (PF) 50 mg/mL Ophthalmic Solution, Lot number t0 Unit, Lot # (b)(4). 3) The [(b)(4)] mg/mL Injectable Solution, Lot number 04052016@1. B) The [(b)(4)] has not been validated. (b)(4) was installed prior to April 2015 and was not validated following the following: a) Effective sterilization of the following items through (b)(4): oils; ophthalmic base solutions; glass bottles; caps and stoppers. b) Effective depyrogenation of lab glassware used in sterile drug production through the depyrogenation time and temperature cycle. 2) The Log Instructions & Notes for final sterilization 250 mg/mL Injectable require to "[ (b)(4) ]" the vial have f (b) [(b)(4)] is used for each sterilization to show r (b)(4) was used during the sterilization of the following items: a) Hydroxyprogesterone Caproate (Sesame Oil Solution) 250 mg/mL. b) Hydroxyprogesterone Caproate (Sesame Oil Solution) 250 mg/mL, Lot number 042215-RR. c) Hydroxyprogesterone Caproate (Sesame Oil Solution) 250 mg/mL. C) The r (b)(4) S/N t[(b)(4)] following installation to confirm effective sterilization time and temperature cycle: empty ointment tubes; metal utensil. D) An in situ air pattern analysis (smoke study) of the ISO 5 LFH and clean room has not been conducted to demonstrate unidirectional air flow for sterile drug products under dynamic conditions. E) (b)(4) used in sterile drug production are sterilized [illegible].
Show observations 3 to 7
- Observation 3
Inadequate aseptic techniques observed
OBSERVATION 3 Procedures designed to prevent microbiological contamination are not established or followed. Specifically. A) The following inadequate aseptic techniques were observed: 1) An operator was observed working at the r (b)(4) ISO 5 LFH with parts of the non-sterile garbing materials exposed inside and on the ISO 5 LFH work surface. For example, a. On April 25, 2016 an operator was observed manipulating components for Cataract Block Solution (Bupivicaine-Lidocaine and Epinephrine-Hyaluronidase) 3.52 mg-9.38 mg-9.4 u/mL, lot number 04252016@1 with the elbows of the non-sterile disposable labcoat resting on the work surface of the ISO 5 LFH. b. On May 2, 2016 an operator was observed manipulating components for Tobramycin 14 mg/mL Ophthalmic Solution, Lot number t05022016@42 and Vancomycin (PF) 50 mg/mL Ophthalmic Solution, Lot number t05022016@43 with the waist in contact with the work surface and with the wood paneling that was observed to be partially detached from the underside of the ISO 5 LFH with exposed yellow fibrous material. 2) On May 2, 2016 an operator was observed bringing a non-sterile labcoat from the ISO 8 anteroom into the ISO 7 clean room while wearing sterile latex gloves with direct contact with the non-sterile disposable labcoat. The gloves were not sanitized with sterile r (b)(4) prior to entering. The operator did not change the non-sterile disposable lab coat prior to the production of Tobramycin 14 mg/mL Ophthalmic Solution, Lot number t05022016@42 and Vancomycin (PF) 50 mg/mL Ophthalmic Solution, Lot number t05022016@43. 3) On May 2, 2016 an operator was observed grabbing a black cord attached in the ISO 8 anteroom and pushing it through a [(b)(4)] using an orange extension cord. The operator's non-sterile lab coat was observed to be in direct contact with the cord; the mop handle and an (b)(7) sleeve was indirect contact with the non-sterile labcoat. The operator did not change prior to sterile drug production. 4) On May 2, 2016 an operator was observed removing previously used materials and components from the ISO 5 LFH and then stage new materials and components without first sanitizing. For example, a. Materials and components used in the manufacture of Tobramycin, lot number t05022016@42 were removed from the ISO 5 LFH, and a lot of 0 Sodium Hydroxide were staged to manufacture a Nitro Hydroxyl product, with contaminated gloves. b. Materials and components used in the manufacture of Vancomycin in the ISO 5 LFH, and materials and components necessary to manufacture Vancomycin (PF) 50 mg/mL Ophthalmic Solution, Lot number t05022016@43 were staged without changing/sanitizing gloves. B) SOP 9.110 Sterile Compounding Process Validation (Media Fills) - Section 9.2 Incubation and Inspect Media-Filled Units states in part "** (b)(4) ...". The following media fills performed were not (b)(4) recorded by the operator performing the media fill and not recorded in addition to the following: 1) Media Fill Test Formula Worksheet. Date made: (b)(4) temperature at (b)(4) days of (b)(4) and the date at (b)(4). The media fill test were also not recorded. 2) Media Fill Test Formula Worksheet, Date made: (b)(4) with no date written, and [(b)(4)] locality by son. a. Pass at n days [(b)(4)] without allowing for the required incubation period. 3) Media Fill Test Formula Worksheet. Date made: (b)(4) checks only from [(b)(4)]. The operator indicated that the results were a pass. 4) The start and stop time of the media fill test were also not recorded. 5) Media Fill Test Formula Worksheet. The operator does not indicate a date made for the media, the dates when the media was placed under incubation, and indicated that the results as a "pass" [(b)(4)]. The operator only indicates the start date and temperature [(b)(4)] and the dates at [(b)(4)] were a "PASS" [(b)(4)]. The start and stop time of the media fill test were not recorded.
- Observation 4
Environmental monitoring deficiencies
OBSERVATION 4 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically. A) Your environmental monitoring procedure SOP 3.030 is deficient in that there is no scientific rationale to support the frequency and methodology of testing. 1) Surface sampling for microbiological monitoring is not performed each day in the ISO 5 LFH when sterile drugs are produced. SOP 3.030 - Section 9.5.2 states in part. The most recent [(b)(4)] was performed in 2016. 2) Viable air monitoring is not performed in the [(b)(4)] where sterile products are produced. SOP 3.030 - Section 9.4 states [(b)(4)]. 3) Non-viable air monitoring is not performed in the [(b)(4)] where sterile products are produced. Non-viable air monitoring is [(b)(4)]. The most recent [(b)(4)] non-viable air sampling was performed on February 5, 2016. 4) Personnel monitoring of operators is conducted per SOP [(b)(4)]. No other surface samples were taken [(b)(4)] sampled [(b)(4)]. 5) The positive air pressure differential was not being monitored continuously between the ISO 8 anteroom and the ISO 7 clean room and unclassified hallway during production of sterile products prior to the [(b)(4)]. The positive air pressure differential began on November 12, 2015.
- Observation 5
No sterility testing of finished batches
OBSERVATION 5 Each batch of drug product purporting to be sterile is not tested to ensure it meets sterility requirements. Specifically, sterility testing is not performed on each finished batch or representative samples of finished sterile drug products. For example, sterility testing is not performed on batches of the following sterile products: (1) Tobramycin 14 mg/mL Ophthalmic Solution, Lot number t05022016@42 (BUD 30 days refrigerated) and (2) Vancomycin HCl (PF) 50 mg/mL Ophthalmic Solution, Lot number t05022016@43 (BUD 14 days refrigerated).
- Observation 6
Missing potency/stability data for products
OBSERVATION 6 Drug products do not bear an expiration date determined from appropriate stability testing and applicable standards of identity, strength, quality and purity. Specifically, potency studies have not been conducted or conducted according to SOP 9.120 Sterile Compounding Finished Preparation. In part "** (b)(4) method or samples shall be sent to a contract lab for testing." For example, there is no potency study data for Alprostadil to support the beyond-use date (BUD) of (b)(4). The following products with the same lot number (b)(4) Alprostadil (b)(4) were observed under (b)(4): • Alprostadil-E I (Prostaglandin) Lot number 012016-QQ 7/20/2016 frozen Alprostadil (b)(4) Lot number [illegible]. • Alprostadil-Papaverine HCl-Phentolamine MES (Triple Mix #5) Lot number 03072016@61 Expires 30 days after thawed and refrigerated or 06/27/2016 frozen [Alprostadil (b)(4). Exp. date 6/27/2016]. • Alprostadil-Papaverine HCl-Phentolamine MES (Triple Mix #21) Lot number 03092016@29 Expires 30 days after thawed and refrigerated or 08/28/2016 [Alprostadil (b)(4). Exp. date 8/28/2016]. • Alprostadil-E I (Prostaglandin) Lot number 04042016@80 Beyond compounding date [Alprostadil (b)(4) Lot number (b)(4)]. Additional Alprostadil preparations were observed thawed and refrigerated or frozen with various beyond-use/expiration dates that lacked supporting potency/stability data.
- Observation 7
Inadequate personnel clothing/gowning
OBSERVATION 7 Clothing of personnel engaged in the manufacturing and processing operations is not appropriate for the duties they perform. Specifically, the attire worn by an operator on April 25, 2016 during the production of Cataract Block Solution (Bupivicaine-Lidocaine and Epinephrine-Hyaluronidase) 3.52 mg-9.38 mg-9.4 u/mL and on May 2, 2016 during the production of Tobramycin 14 mg/mL Ophthalmic Solution, Lot number t05022016@42 and Vancomycin HCl (PF) 50 mg/mL Ophthalmic Solution, Lot number t05022016@43 was inadequate as follows: A) An operator was observed working in the [(b)(4)] wearing a sterile head cover, non-sterile surgical mask, non-sterile disposable labcoat and non-sterile shoe covers. B) The disposable non-sterile surgical mask and non-sterile head cover worn did not provide adequate coverage to the forehead, neck or face. C) Prior to donning sterile latex gloves in the ISO 5 LFH, loose items were stored outside of their original packaging on a shelf in the ISO 8 anteroom. D) Non-sterile scrubs that are worn under the non-sterile garments are personally laundered by the operators.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006317860 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006317860. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.