Skip to content

Gipsco Investment Corp

23865 Mercantile Rd, Beachwood, Ohio, United States

FEI 3005457901

FDA has 3 inspections on file for Gipsco Investment Corp in Beachwood, Ohio (FEI 3005457901), from 2017 to 2022. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Jun 9, 2017. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
3, 2017–2022
1 OAI · 0 VAI · 2 NAI
Inspections with 483 observations shown
1 of 3
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate HEPA filter/airflow gap

      1) There is inadequate HEPA-filter coverage or airflow. Specifically, May 5, 2017, we observed a gap in the roof of (b)(4) laminar airflow hood which is to be larger than the syringes being filled, causing over the area to which sterile product is exposed, approximately [illegible] inches, across the back of the HEPA screen used to fill syringes of sterile drug products. The gap appears to be below the level of ISO 5 airflow.

    2. Observation 5

      Unsealed/loose ceiling lights

      5) Unsealed, loose ceiling lights were observed in the cleanroom. When entering from the ISO 8 anteroom, [the light] is not fully seated [illegible] behind the housing, and is not sealed. Specifically, the first light in the ISO 7 cleanroom is not fully seated in its housing, causing a gap into the area.

    Show observations 6 to 9
    1. Observation 6

      Inadequate pressure differentials/gaps

      6) Pressure differentials between areas with different drug production. a. The pressure [illegible] is between the ISO 7 [illegible] during [illegible] production. b. There is a gap in the doors on both sides of the pass-through between the supporting unclassified areas that allows palpable airflow between the areas. Air classifications were not monitored prior to or during sterile drug production.

    2. Observation 7

      ISO-5 not certified dynamically

      7) ISO-5 classified areas were not certified under dynamic conditions. Specifically, the smoke studies performed to demonstrate the laminar air flow in the (b)(4) cabinet used to produce sterile drug products did not have enough smoke to visualize the airflow at critical [illegible] and do not reflect all types or operations performed.

    3. Observation 8

      Inadequate sterilization cycle parameters

      8) The cycle parameters used for (b)(4) to inactivate heat-resistant microorganisms are inadequate. For instance, the production of sterile drug products only reached a temperature of (b)(4) instead of the intended cycle of (b)(4) degrees between 8/10/16 and 3/28/17. Sterilization for products intended to be sterile are not lethal. (b)(4) cycles intended to sterilize equipment used in the production of sterile drug products only reached (b)(4) degrees Celsius, despite the fact that the instructions state (b)(4) degrees Celsius.

    4. Observation 9

      No/incorrect biological indicator use

      9) Biological indicators were not used to verify the adequacy of the sterilization cycle. a. The biological indicators that ensure cycle effectiveness for glassware used in sterile drug production and products have been incubated at temperatures [illegible]; instructions state that they are to be incubated at [illegible]. b. The biological indicators that ensure cycle effectiveness for equipment used in the production of sterile drug products were incubated at (b)(4) degrees Celsius on 9/1/16, at (b)(4) degrees Celsius for (b)(4) different loads on 12/16/16; they should be incubated at (D)(4) degrees Celsius.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005457901 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005457901. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.