Skip to content

Peoples Pharmacy, Inc.

3801b S Lamar Blvd, Austin, Texas, United States

FEI 3005331940

FDA has 2 inspections on file for Peoples Pharmacy, Inc. in Austin, Texas (FEI 3005331940), from 2014 to 2017. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Dec 22, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Jul 28, 2014. No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2014–2017
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Use of non-pharmaceutical grade components

      Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. For example, a) Your firm uses water from a (b)(4) system for use in certain drug products whose formulation requires water. Your firm is also using the water from the (b)(4) system to make (b)(4) Water for use in certain drug products. Your firm has no documentation of testing performed (microbiological or analytical) to show the water at least/at minimum meets the specifications for Purified Water, USP. Examples of lots made using the (b)(4) water include lot #11-27-2017@32 of Clonidine (Dye Free/Flavor Free) 0.05mg/mL Suspension and lot #11-13-2017@3 of Omeprazole (Grape/Marshmallow) Standard+2mg/mL Suspension. Examples of products made using the (b)(4) Water made from the (b)(4) water include lot #11-12-2017@12 of Dexamethasone/Mupirocin/Amphotericin B (b)(4) 0.1%/100mg/10mg/60mL Nasal Spray and lot #06-15-2017@21 of Tranexamic Acid 5% Solution. b) Your firm uses Acetone CP grade for (b)(4) making (b)(4) drug products. The Acetone is labeled for "technical use only". In the past 6 months your firm has made (b)(4) lots of drug products using Acetone CP including (b)(4) of Squaric Acid Dibutyl Ester/Acetone 0.5% Solution and (b)(4) of Diphenylcyclopropenone 5% Solution.

    2. Observation 2

      Inadequate containment and cleaning

      Hazardous or highly potent drugs were produced without providing adequate containment, segregation and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, I observed on 11/30/17 that the rubber spatulas used in the production of non-sterile drug products were discolored, cracked and damaged [illegible]. There were several lots of different products made on the date including lot #11-30-2017@5 of Estradiol (E2)/Prog (P4) 0.5mg/100mg/GM Cream.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    2. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005331940 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005331940. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.