Region Care, Inc.

200 Community Dr, Great Neck, New York, United States

FEI 3005287250

FDA has 2 inspections on file for Region Care, Inc. in Great Neck, New York (FEI 3005287250), from 2014 to 2016. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jun 17, 2016 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Mar 20, 2014. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2014–2016
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate sterilization validation

      1. Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, a. Smoke studies, performed by an outside vendor (b) (4), are not conducted under dynamic conditions that simulate routine aseptic operations. Consequently, there is no assurance that uninterrupted unidirectional laminar airflow is maintained during aseptic operations. b. The HVAC returns in Cleanroom (b) (4) were observed to be obstructed by wire racks containing drug components and other supplies, as well as by garbage cans.

    2. Observation 2

      Sterility and endotoxin testing omitted

      2. Drugs products purporting to be sterile and pyrogen-free are not laboratory tested to determine conformance with such requirements. Specifically, Sterile drug products prepared from non-sterile starting materials (e.g. morphine, hydromorphone, bupivacaine, and baclofen) are not tested for sterility and bacterial endotoxins (pyrogens) prior to release.

    Show observations 3 to 8
    1. Observation 3

      Environmental monitoring deficiencies

      3. Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Work surfaces, inside the ISO-5 workstations, are not sampled at least daily during periods of production. For example, review of the (b) (4) Compounding Activity (b) (4) Log found there was no such testing on the following days: 05/05/2016, 05/09/2016, 05/10/2016, 05/12/2016, 05/16/2016, and 05/19/2016. However, review of the prescription log indicated sterile drug products were prepared on each of these days. b. Viable air sampling is not performed at least once daily on days of aseptic operations. c. Magnehelic gauges (manometers) used for monitoring pressure differentials between classified rooms, including the ISO-7 classified cleanroom (which houses ISO-5 classified workstations) and the ISO-7 classified anteroom are not calibrated.

    2. Observation 4

      Missing visual inspection procedures

      4. Laboratory controls do not include a determination of conformance to appropriate specifications for drug products. Specifically, There are no written procedures requiring the performance of visual checks of all sterile drug products for clarity, discoloration or particulates. Furthermore, there is no documentation to support this practice is actually being performed.

    3. Observation 5

      Calibration program not followed

      5. Routine calibration of equipment is not performed according to a written program designed to assure proper performance. Specifically, (b) (4), used to monitor temperature in the ISO-7 classified ante-room and the walk-in refrigerator (used to store drug products) are not calibrated. A sticker on each of the (b) (4) indicates they were last calibrated "03/2014."

    4. Observation 6

      Inappropriate gown reuse

      6. Clothing of personnel engaged in compounding of sterile drug products is not appropriate for the duties they perform. Specifically, Sterile gowns worn by operators preparing sterile drug products are reused throughout the day (i.e. they are not immediately discarded when doffed).

    5. Observation 7

      Inadequate excursion investigations

      7. There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, On at least two occasions, environmental monitoring excursions involving the detection of "single colony" growth from (b) (4) surface and (b) (4) floor samples, respectively were documented and investigated. However, these investigations were inadequate in that: - Remedial cleaning and retesting is not documented as being performed. - They did not include an assessment to determine what compounding activities were occurring at the time and location of the excursion to identify any potentially adverse impact on drug product quality. - The "Actions Taken" section of the Incident Reports state "(b) (4)". However, there is no documentation to support this was actually performed.

    6. Observation 8

      Deficient cleaning and disinfection system

      8. Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a. The [illegible] divider separating the LAFW (laminar airflow workstation) and [illegible] is cleaned only [illegible]. b. An operator was observed dry mopping the floor of the ISO-7 classified ante-room, then enter the more critical ISO-7 classified clean room and continue mopping the floor without changing the mop head; instead of working from the greater to lesser critical area. c. Cleaning procedures are deficient in that the contact time for disinfectants such as (b) (4) are not defined in written procedures or documented in cleaning records.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Failure to investigate sterility failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) Your firm has failed to conduct and document an investigation into the reported sterility failure of Protonix 80mg/100ml 0.9% NaCl; lot# 19P-12125112-R6, which was compounded on 12/12/2013. You did not identify the root cause of the reported (sterility) failure and you did not perform a risk evaluation to determine the impact of this deviation (i.e. other lots of sterile drug products potentially affected). B) Review of the "Gloved Fingertip Sampling Log" found failing results on 12/11/2013, 12/20/2013, and 02/03/2014 for fingertip samples taken from the same pharmacy technician during the compounding of sterile drug products. Products exposed on the referenced dates were observed to contain one (1), two (2), and three (3) colony forming units (CFU), respectively. However, there was no investigation into these environmental monitoring (EM) sample failures to identify a root cause, evaluate risk, or take appropriate corrective/preventive actions (CAPA). It is noted this is the same pharmacy technician who compounded the batch of drug product which failed sterility testing, as described in Observation 1(A), above.

    2. Observation 2

      Deficient environmental monitoring program

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, Your current environmental monitoring (EM) program is deficient in that: A) It does not include daily surface or viable air sampling within the ISO-5 classified areas during sterile compounding (production) activities. B) You do not monitor non-viable particles in ISO-5 classified areas under dynamic conditions. C) There is no environmental monitoring conducted during media fills (process simulations). D) Review of your Environmental Testing Log found (viable) air samples and surface samples from the ISO-5 classified laminar airflow workstations (LAFW) are not incubated and checked for growth as required. You never monitor air-pressure differentials between your ISO-6 classified clean room & ISO-7 classified ante room; or between the ISO-7 classified ante-room & unclassified general pharmacy area. However a panel inside the ante-room holds several manometers, which you acknowledge are not being monitored and may not even be working.

    Show observations 3 to 7
    1. Observation 3

      Facility not maintained in good repair

      Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, During a tour of the ISO-6 classified clean-room we observed peeling paint, chipped drywall, and acoustic ceiling tiles with cut out holes; all of which facilitate dust formation and create a contamination risk.

    2. Observation 4

      Inadequate procedures for components and COAs

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures. Specifically, A) There is a failure to establish acceptance criteria for incoming drug substances, drug product containers and closures, and other components used in compounding sterile drug products; including, but not limited to: hydromorphone active pharmaceutical ingredient (API) (b)(4), sterile tamper-evident syringe caps, and sterile empty glass syringes. B) There is no written procedure and documented practice for the review of certificates of analysis received from component suppliers and control testing laboratories.

    3. Observation 5

      Sterility and endotoxin testing not completed

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance with such requirements. Specifically, Given the observed inadequate environmental controls, testing is deficient in that: Each batch of compounded sterile drug product is released for distribution prior to the completion of bacterial endotoxin testing (BET) and sterility testing. Protonix 80mg/100ml 0.9% NaCl; lot# 19P-12125112-R6 was recalled due to a sterility failure.

    4. Observation 6

      Inadequate cleanroom personnel apparel

      Clothing of personnel engaged in the compounding of sterile drug products is not appropriate for the duties they perform. Specifically, Sterile drug products are aseptically manipulated by the cleanroom operators who wear booties, gowns, face masks, and hairnets which are non-sterile. The only apparel that is sterile is the gloves worn by operators working in the ISO-5 classified areas.

    5. Observation 7

      Missing required labeling information

      The labels for the drug products do not contain information required by section 503B(a)(10). Specifically, Labeling of compounded sterile drug products, including, but not limited to Fentanyl 12.5 mcg/ml - Bupivacaine 0.1875% in 0.9% NaCl do not contain the statement "This is a compounded drug." In addition, the labels do not contain the firm's phone number, the date of compounding, an NDC number or specific storage/handling instructions.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005287250 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005287250. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.