Skip to content

Neway Medical, P.C.

123 W 79th St, New York, New York, United States

FEI 3005002665

FDA has 7 inspections on file for Neway Medical, P.C. in New York, New York (FEI 3005002665), from 2010 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 1271.47(a) and 21 CFR 1271.75(a)(1).

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2010–2024
0 OAI · 5 VAI · 2 NAI
Inspections with 483 observations shown
4 of 7
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest FY2023
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesPosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Donor eligibility not based on screening testing

      HCT/P donors were not determined to be eligible based on the results of donor screening and testing. Specifically, a) Your Donor Screening Questionnaire is used to screen anonymous and directed oocyte and directed semen donors for the risk factors associated with Creutzfeldt-Jacob Disease (CJD) and variant CJD: question #22a "From beginning of 1980 through the end of 1996 did you spend time that adds up to 3 months or more in U.K.?" and question #22b "Since 1980 have you received a transfusion of blood or blood components in the U.K. or France?" Review of (b) (4) anonymous and (b) (4) directed oocyte donor cycle records and (b) (4) directed semen donor records from (b) (4) found that (b) (4) anonymous oocyte donors, directed oocyte donors and (b) (4) directed semen donors did not answer questions #22a and #22b but were determined eligible/ineligible and donated reproductive tissues that were used for in-vitro fertilization with subsequent tissues cryopreserved and/or transferred. Donor Type Total Donor cycles (b) (4) Donors Determined Eligible/Ineligible Tissues Transferred to the Recipients Fertilized Tissues in Storage Anonymous Oocyte (b) (4) (b) (4) (b) (4) Eligible (b) (4) (b) (4) Directed Oocyte (b) (4) Eligible Directed Semen (b) (4) Eligible (b) (4) Ineligible (b) (4) semen vials used) (b) (4) vials cryopreserved) b) Review of relevant medical records for anonymous oocyte donor (b) (4) (b) (7)(C) found that she lived in (b) (6) (b) (7)(C). She was determined eligible on (b) (6) (b) (7)(C) and donated oocytes on (b) (6) (b) (7)(C) that were fertilized and transferred to recipient on (b) (6) (b) (7)(C) with fertilized tissues cryopreserved.

    2. Observation 2

      Summary of records missing ineligibility reason

      The summary of records for HCT/Ps from donors determined to be ineligible based on screening and released for limited use did not contain a statement noting the reasons(s) for the ineligibility. Specifically, Directed oocyte donor (b)(6) tested for (b) (6) (b) (7)(C) and as documented on the Patient Reports dated (b) (6) (b) (7)(C). However, the reason for ineligibility was listed as "Answered " " to HRQ [High Risk Questionnaire, ]".

    Show observations 3 to 5
    1. Observation 3

      No procedures for donor screening eligibility

      You did not establish and maintain procedures for screening and determining the eligibility of HCT/P donors. Specifically, Your standard operating procedures to screen, test and determine donor eligibility do not include all eligibility criteria based on the questions answered on the Donor Screening Questionnaire. This Donor Screening Questionnaire is used to screen anonymous and directed oocyte and directed semen donors. Some examples are: men who had sex with another man in the preceding 5 years and persons who had sex in the preceding 12 months with these men; and persons who have been in juvenile detention, lock up, jail or prison for more than 72 consecutive hours in the preceding 12 months.

    2. Observation 4

      Donor eligibility records not accurate legible

      Donor eligibility records are not accurate and legible. Specifically, a) On [illegible], directed semen donor [illegible] answered "[illegible]" to question [illegible] on the Donor Screening Questionnaire: "In the past 12 months, have you had or been treated for [b)(6) (b)(7)(C)] [illegible]?" and "In the past 12 months, have you [illegible] with anyone who would answer [illegible] to questions [illegible]?" However, this directed semen donor [illegible] Health History and Physical Examination Form dated [illegible] documents that there was no history of [b)(6) (b)(7)(C)]. b) [illegible] anonymous oocyte donors, [illegible] directed oocyte donors and [illegible] directed semen donors had incomplete screening but were determined eligible in [illegible]. Their reproductive tissues were recovered, used for fertilization procedures, cryopreserved and/or transferred to the recipients. These anonymous oocyte and directed oocyte and semen donors eligibility was changed to ineligible by the Medical Director in 2023. c) On [illegible], directed oocyte donor [illegible] tested [illegible] for (b)(6) (b)(7)(C), as documented on the Patient Report dated [illegible]. However, the Summary of Records dated (b)(6) (b)(7)(C) test as Non Reactive and interpreted as Normal.

    3. Observation 5

      Procedures not ensuring donor eligibility compliance

      Procedures were not designed to ensure compliance with the donor eligibility requirements. Specifically, Your standard operating procedure entitled Testing, section 2.2 entitled Diseases To Test For And Result Interpretations states for [illegible] and [illegible] testing: "If the results are positive, a confirmatory [illegible] test will be used to determine the status of the donor. This is due to the potential for the initial result to be a false-positive result." On [illegible], directed oocyte donor [illegible] tested [illegible] for [illegible] (b)(6) (b)(7)(C). Her supplemental assay test interpretation was [illegible]. On [illegible], this directed oocyte donor [illegible] was retested again and tested [illegible] for the [illegible] test with the [illegible] supplemental assay. [(b)(6) (b)(7)(C)] result was documented on the Summary of Records for (b) (4) dated (b) (4).

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Risk factors, leukocyte-rich cells or tissues

      Donors of leukocyte-rich cells or tissues were not screened by a review of relevant medical records for risk factors and clinical evidence of cell-associated communicable disease agents and diseases.

    2. Listing and interpretation of CD tests performed

      The summary of records for HCT/Ps did not contain a listing and an interpretation of results of all communicable disease tests performed.

    3. Risk factors, clinical evidence

      Donors were not screened by a review of relevant medical records for risk factors and clinical evidence of communicable disease agents and diseases.

    4. Accurate, indelible, legible

      Donor eligibility records are not accurate, indelible and legible.

    5. Name and personal info on accompanying records

      The accompanying records for HCT/Ps included the donor's name.

    Show 2 more citations
    1. Results, interpretation of CD screening

      Documentation of the results and the interpretation of all donor screening for communicable diseases was not maintained.

    2. Design of procedures to ensure compliance

      Procedures were not designed to ensure compliance with the donor eligibility requirements.

  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for all other requirements

      Procedures for all steps performed in the screening and determining of donor eligibility of HCT/Ps were not maintained, defined, documented, reviewed and revised.

    2. Risk factors, clinical evidence

      Donors were not screened by a review of relevant medical records for risk factors of communicable disease agents and diseases.

  4. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for all other requirements

      Procedures for all steps performed in the screening and determining of donor eligibility of HCT/Ps were not defined and documented.

  7. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Nov 8, 2022VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-5107Form 483Closed
  • Inspection ending Mar 27, 2019VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Nov 30, 2023FDA-FOIA-2023-10680Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 3 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 7 inspections, with how many of them cited each.

  • 21 CFR 1271.47What procedures must I establish and maintain?3 of 3
  • 21 CFR 1271.75How do I screen a donor?2 of 3
  • 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?1 of 3

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005002665 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005002665. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.