Pharmacy Innovations
2936 W 17th St, Erie, Pennsylvania, United States
FEI 3004858203
FDA has 2 inspections on file for Pharmacy Innovations in Erie, Pennsylvania (FEI 3004858203), from 2017 to 2022. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations I).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2017–2022
- 1 OAI · 0 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER · Division of Pharmaceutical Quality Operations I ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate HEPA/airflow coverage
There is inadequate HEPA filter coverage or airflow over the area to which sterile product was exposed. Specifically, 1. Your HEPA coverage area in the (5) (L1-) ISO 5 laminar airflow workbench (LAFW) in the non-hazardous sterile cleanroom has light pod areas that are approximately 6 inches long and surrounded by suspended ceiling tiles that is not sealed around the perimeter of the tile which sits in between each HEPA filter. On 11/2/2022, we observed your vendor perform a dynamic smoke study which illustrated that the ISO 5 air is turbulent and not unidirectional underneath the light pod areas. Prostaglandin E1 30CC/ML, Lot: t20221103@::::.: was prepared in an area that does not have adequate HEPA filter coverage in the ISO 5 LAFW. 2. The ISO 5 LAFW lacks unidirectional airflow in critical areas where drug products intended to be sterile are produced. On 11/2/2022, we observed your vendor perform a dynamic smoke study which showed the air is not unidirectional where drug production is occurring at the LAFW table top. We also observed Prostaglandin E1 30CC/ML, Lot: t20221103@(b)(~I be prepared in an area that did not have ISO 5 HEPA filter coverage. 3. During the walkthrough on 11/2/2022, we observed a rust-like discoloration on the HEPA filter on the left side of your ISO 5 Laminar Flow Air work bench area in the non-hazardous sterile cleanroom. The discolored rust-like HEPA filter supplies air directly to the area where sterile drug products intended to be sterile are produced. 4. During the walkthrough on 11/2/2022, we observed yellowing discoloration on three out of the (b)(4) HEPA filters installed in your (b)(4) ISO 5 LAFW where sterile drug products intended to be sterile are produced. 5. Your HEPA filter on the left side of your ISO 5 LAFW appears to have evidence of (b)(4) on the diffuser screen and HEPA filter. Additionally, there appears to be (b)(4) on the HEPA filter in the ISO 7 (b)(4) cleanroom of the non-hazardous sterile cleanroom suite.
- Observation 2
Media fills not representative
Media fills were not performed that closely simulated aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, A. Your media fill program is deficient in that your media fills are not representative of batch sizes and container types. Your media fills are performed in (6) ("1-) However, your firm prepares (b)(4) using other container types that yield the following: up to (b)(4) filled at (6)(4) up to (b)( ) syringes (filled at (6) ("1-) , up to (b)(4) eye drop-containers (filled at (b)(4) , and (b)(4) inhalation tubes (filled at (b)(4). B. Your media fill program is deficient in that media fills do not include all equipment used in the preparation of drug products intended to be sterile. For instance, a (6)(4) is used to fill an IV bag to dose liquid drug product intended to be sterile into syringes for bladder irrigation prescriptions.
Show observations 3 to 9
- Observation 3
Insufficient smoke studies
Your firm failed to perform adequate smoke studies under dynamic conditions to demonstrate unidirectional airflow within the ISO 5 area. Specifically, the smoke studies performed to demonstrate the (b)(4) laminar air flow in the (b)(4) ISO 5 laminar airflow workbench used to produce drug products intended to be sterile do not have enough smoke to visualize the airflow at critical production areas, do not illustrate unidirectional airflow, and do not reflect all types of operations performed in the areas. Additionally, the (b)(4) airflow from the ISO 5 LAFW was observed bouncing back from the wall along the workbench and exiting at the point where the Plexiglas stopped causing first pass air to not appropriately sweep over and away from drug products intended to be sterile.
- Observation 4
Poor air influx from facility design
The facility design was observed to allow the influx of poor quality air into higher classified area. Specifically, A. While watching sterile cleanroom activities on 11/07/2022, we observed (b)(4) remain open simultaneously following (b)(4) to the unclassified non-sterile non-hazardous laboratory area as an employee was leaving the non-hazardous sterile cleanroom suite. Additionally, this occurred while another employee was preparing to enter the ISO 5 LAF workbench for sterile drug production. B. During the walkthrough on 11/02/2022, we observed a rust-like discoloration on the diffuser of one HEPA filter in your ISO 7 anteroom of your non-hazardous sterile suite, where we observed employees prepare and mix drug products.
- Observation 5
Inadequate environmental monitoring
Environmental monitoring was not performed in your aseptic processing areas. Specifically, 1. Your aseptic employee changed their sterile gloves used during the sterile drug production of Prostaglandin E1 30CC/ML, Lot: t20221103@(b)(~), with a new pair of sterile gloves outside of the ISO 5 LAF, enter the ISO 5 LAF, sprayed their hands and performed one task prior to completing their (b)(4) monitoring samples. This is not representative of actual processing conditions in the ISO 5 LAFW, and may not provide meaningful results. 2. Your aseptic employee lightly [illegible] (b)(4) plate rather than roll them side to side when performing personnel monitoring after the sterile drug production of Papaverine/Phentolamine 30MG/3MG/ML injectable, Lot: t20221103@(b)(4).
- Observation 6
Aseptic manipulations blocking first-pass air
Personnel were observed conducting aseptic manipulations or placing equipment/supplies in an area that blocked the movement of first pass air around uncapped syringes, whether before or after it is filled with sterile product. Specifically, 1. On 11/04/2022, during the preparation of Prostaglandin E1 30CC/ML, Lot: t20221103@(b)(4), we observed your employee's gloved hand directly over an open syringe in (b)(4) orientation that blocked first pass air in the (b)(4) ISO 5 LAFW. 2. On 11/07/2022, during the preparation of Papaverine/Phentolamine 30MG/3MG/ML injectable, Lot: t20221103@(b)(4), we observed your employee holding the (b)(5) (4) drug product filled syringe in (b)(4) position that blocked first pass air in the ISO 5 LAFW. Your employee was also observed removing drug product from the syringe to be placed into a vial in (b)(4) orientation that blocked the critical areas from receiving first pass air flow from the (b)(4) ISO 5 LAFW bench area. 3. On 11/07/2022, during the preparation of Papaverine/Phentolamine 30MG/3MG/ML injectable, Lot: t20221103@(b)(4), your employee was observed working above the syringe of open (b)(4) drug product, having their gloved fingertips touch the hub of the syringe, handle the (b)(5) (4) with gloved fingertips at the downstream end of the (b)(4), and using their gloved fingertip to touch the filling needle while blocking first pass ISO 5 air flow. Furthermore, your employee was observed placing their gloved hand directly over the sterile vials before drug product intended to be sterile was introduced into the vial. 4. Additionally, on 11/07/2022, we observed your employee moving rapidly in the ISO 5 while producing Papaverine/Phentolamine 30MG/3MG/ML injectable, Lot: t20221103@(b)(4) which caused the syringe to drop back onto the ISO 5 LAFW surface. 5. On 11/07/2022, during the preparation of a hazardous drug, Testosterone injectable, Lot: t20221107@(b)(4), we observed your employee holding the (b)(6) (4) drug product filled syringe (b)(4) position with the filling needle pointing away from first pass air in your ISO 5 Biological Safety Cabinet (BSC). Your employee was observed transferring the (b)(4) drug product from the syringe to another syringe and proceeded to move the (b)(4) syringe in (b)(4) and away from first pass ISO 5 air. Furthermore, we observed your aseptic employee had an excess of materials and trash on the grill of the biological safety cabinet as they prepared drug products intended to be sterile.
- Observation 7
Dirty or hard-to-clean ISO equipment
The ISO-classified areas have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, 1. On 11/09/2022, I observed employees clean the ISO 5 area while wearing non-sterile lab coats. 2. Use of sporicidal agents in the ISO 5 is inadequate. Sporicidal agents are not used on the Plexiglas that extends across the length of the (b)(4) ISO 5 LAFW in the non-hazardous sterile cleanroom. Additionally, there appears to be a crack in the Plexiglas that starts at a nail and runs to the edge of the glass, as well as two gaps in the plexiglass, approximately 10 millimeters in size, which may not be easily cleanable, and may harbor contamination. 3. Your ISO 5 LAFW has nail sized holes in the wall immediately in front of the work space where drug products intended to be sterile are prepared. 4. (b)(4) plates with rust-like discoloration are sitting in the ISO 5 LAFW of the non-hazardous sterile cleanroom suite ((b)(4) plates can be used to mix prepared media required during the media fill process in the ISO 5 LAFW). 5. The return vents below the ISO 5 LAFW bench tops appear to be rusty. According to your firm's employee, they have to access this area when they need to plug in the (b)(6) (4) which is used in the production of sterile drug product. 6. Your hazardous sterile ISO 5 biological safety cabinet had dust and discarded needles, caps, and wrappers underneath the work surface where drugs intended to be sterile are produced.
- Observation 8
Non-sterile disinfectants/wipes used
Disinfecting agents and cleaning wipes used in the ISO 5 area aseptic processing areas are not sterile. Specifically, on 11/04/2022 and 11/07/2022, we observed employees use (b)(4) to clean and sanitize materials entering into the ISO 5 LAFW areas. Your employee was observed spraying a (b)(4) and then cleaning the work surfaces and equipment inside of the ISO 5 LAFW bench area. Additionally, the (b)(4) was observed moving from the ISO 8 Anteroom/Gown (b)(4) to the ISO 5 (b)(4) cleanroom to be used and placed in the ISO 5 LAFW bench area without being sanitized.
- Observation 9
No biological indicators used
Biological indicators were not used to verify the adequacy of the sterilization cycle. Specifically, 1. Your firm failed to use biological indicators (B.I.s) to ensure cycle effectiveness in (b)(4) cycles intended to sterilize (b)(4) drug products produced from March 2022 to July 2022. For example, your firm produced the following drug products without any biological indicators: a. Phenol Injection, Lot #s: t20220406@ , t20220621@ t20220505@ , b. Vitamin D3, Lot #s: t20220303@ , t20220304@ , t20220322@ , t20220419@ , t20220504@ , t20220506@ , t20220517@ , t20220613@ , c. Glycerin, Lot #s: t20220303@ , t20220309@ , t20220421@ , t20220603@ , d. Prednisolone, Lot #s: t20220519@ . Your firm failed to use B.I.s to ensure the cycle effectiveness in (b)(4) of the (b)(21) cycles used to sterilize (b)(4) that is added to sterile drug products and also used to (b)(4) glassware used in drug products intended to be sterile from January 2022 to September of 2022. Additionally, you carry the (b)(4) that is intended to be sterilized through the unclassified area to the ISO 5, lacking assurance of the product being protected.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations I · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004858203 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004858203. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.