Skip to content

NerPharMa S.r.l.

Italy

FEI 3004762406DUNS 338839192

FDA has 8 inspections on file for NerPharMa S.r.l. in Italy (FEI 3004762406), from 2009 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below. Three of the 14 FOIA requests for this site have asked FDA for this inspection's 483.

1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing and analysis, through Dec 31, 2027. Its registrant is NerPharMa S.r.l (D-U-N-S 338839192).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
8, 2009–2025
0 OAI · 5 VAI · 2 NAI
Inspections with 483 observations shown
1 of 8
Form 483s posted by FDA
↗
Requested under FOIA
14 requests, latest FY2023
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Aseptic process validation deficiencies

      Procedures designed to prevent microbiological contamination did not include adequate validation of the aseptic and sterilization process. Specifically, A) Inherent and corrective interventions and the times/durations in which they occur, are not always documented within batch production records as required. Allowed Interventions During Aseptic Processing on assurance the maximum number of production are accurately simulated during media fills. B) Media fills are performed using a split batch approach, where some units are transferred to the [(b) (4)] to represent the filled as [(b) (4)] operations. C) During Aseptic Process Simulations, Step [illegible] any vials from the filling line". However, during the December 2023 and the subsequent six media fills performed in 2024 for the vial filling line performing weight checks. The following are amounts to performing weight checks: D) The initial [(b) (4)] vials filled on day 1 and [(b) (4)] removed for sterility testing. These vials are not subject to the inverted incubation condition required by media fill. E) During the inspection, we reviewed videos of the filling line [(b) (4)]. This line is for all U.S. injectables. We also observed your smoke studies did not provide assurance the unidirectional airflow (first air) was always maintained. The following were noted: 1. No smoke studies (at rest or in operation) were performed [(b) (4)]. [(b) (4)] were used to transport components or accessories required. 2. Video #16 "Stopper Loading": an updraft of airflow near a metal frame in the ceiling below the area where stopper bags were cut open for loading. 3. Video #6 "At rest" [(b) (4)] showed an extended Grade A [(b) (4)] near a ceiling light fixture. [(b) (4)] observed turbulent airflow. 4. Video #24 "Filled [(b) (4)]": vials being moved from the filling line blocked first air to the vials in the area under a mechanical arm over vials. 5. Video #31 "Removal": stopper stuck in [(l5) ("1-)] showed an operator blocked first air removing a stuck stopper from the stopper bowl. 6. Video #29 "Removal of stuck/broken/inverted vials" showed an operator blocked first air; impacted vials were not rejected. 7. Video #22 "Removal [(l5) ("1-)]": operator removed stuck seals. We observed this operator blocked seals and [(b) (4)] by placing his hands and arms directly over the feeding chute. 8. Video #16 "Stopper Loading" (in operation) showed the operator partially blocked first air; the operator used quick shaking motions. 9. Video #10 "At rest [(6) (4)] machine" showed laminar airflow leaving the wall and creating an upward swirl of airflow; observed turbulent airflow. F) The vial filling line [(b) (4)] was modified in 2024; the following were noted: 1. Procedure for [(l5) (4)] integrity testing: tears or defects can be adequately detected. Failures have been observed since the installation and qualification of [(l5) (4)]. On 16-June-2025, we watched a demonstration where [(b) (4)] tested failed integrity test. 2. The [( ) (.:l1) Leak Test [IN/GLT/0] has not been performed to adequately qualify [(b) (4)]. 3. Procedure TD186 section 4.3 states [(illegible)] times. Evaluation has been performed; numbers of sterilization cycles are based on vendor's recommendation. 4. Each [(b) (4)] is not assigned a unique identification number to assure traceability. G) During the inspection, we observed aseptic operators using damaged gloves with holes and therefore had exposed skin during filling line set-up and aseptic processing. Used goggles had numerous open holes that created pathways for contamination to enter the cleanroom environment, affecting product sterility.

    2. Observation 2

      Environmental monitoring system failures

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A) Procedure TF002, Injectables: Microbial Enviro Version: 44, requires all Grade A and B microbial recoveries to be identified down to the Genus and Species level. Since January 2023 there have been approximately 457 instances where microorganisms have been recovered during personnel monitoring. Of the 457 instances, the organisms have only been identified 55 times (approximately 88% not identified). B) Active air sampling is not performed due to insufficient space to place active air samplers. C) You did not place the non-viable particle (NVP) monitoring probes in representative locations where the product was exposed. We noted the NVP monitoring probe was approximately [(6) (4)] station where [(6) (4)] to the LAF [(D) (4)]. The NVP monitoring probe was a [(l5) (4)] station where [(6) (4)] to the LAF [(b) (4)].

    Show observations 3 to 8
    1. Observation 3

      Disinfectant efficacy and sanitization gaps

      Aseptic processing areas are deficient regarding the system and equipment to produce aseptic conditions. Specifically, A) The disinfectant efficacy studies are deficient. 1. The studies were not performed using representative Gram negative, yeast, and spore forming microorganisms for disinfectants [(b) (4)]. Additionally, gram negative and yeast organisms have not been evaluated as part of the study for [(b) (4)]. 2. Disinfectant efficacy studies have not been performed on the Grade A filling line [(b) (4)]. B) There is a lack of [(6) (4)] for the vial line [(b) (4)] and adjacent cleanrooms. 1. The biological indicator (BI) and chemical indicator (CI) locations were not determined by risk assessment. Their locations were based on vendor recommendations. 2. There is a lack of written procedures to assure rooms are appropriately prepared to receive product and that rooms are adequately prepared, including temperature and [(b) (4)] relative humidity. C) Performance of sanitization of the Grade A Vial Filling Line [(b) (4)] was not documented until 05-July-2024. There is no assurance that cleaning was performed as required. D) The logbook which documents the sanitization of the Grade A Vial Filling Line [(b) (4)] did not list which disinfectant agent was used to sanitize the line. E) Contact times are not documented on cleaning records for the filling machine [(b) (4)] to ensure the minimum contact time for each solution used has been met.

    2. Observation 4

      Incomplete investigations and OOS handling

      Written records are not always made of investigations into unexplained discrepancies or the failure of a batch or any of its components to meet specifications. Specifically, A) Deviations opened in response to microbial action limit excursions within the Grades A and B filling area are not closed in a timely time. For example, deviation opened 03-April-2025 due to settle plate action limit excursions (Grade B areas) with the following results: [table with location/specification] [(b) (4)]. To date, the investigation for the microorganisms recovered during these action level excursions have not been completed and the microorganisms recovered have not been identified. B) Out-of-Limit # OO~.CM.031.2c~c of both bacterial and mold recovered in Grade B area location Room [(o)] on 13-June-2025 without identification during the current FDA inspection, not both of again, however, the other identification. C) [(6) (4)] Injection visual inspection with 26.27% [illegible] specification for major category was performed only on the [(6) (4)] presence of product on the inner surface of the vial. A reinspection of these vials resulted in the remaining [(~) vials being deemed acceptable and released for the batch release. Deviation DP015/2025: acceptable vials were not re-inspected and used for the re-inspection. This led to [illegible]. D) The three out-of-specification (OOS) investigations for [(b) (4)] batches # [(o) (~)] were not closed in a timely time. The following OOS show: Batch Number OOS Number DP RS/231/2024/04 [(b) (4)] DPFS/231/2025 [(b) (4)] DPFS/231/2025 [(b) (4)]

    3. Observation 5

      Inadequate visual inspection procedures

      Your firm failed to establish adequate written procedures to assure that the drug products have the identity, strength, quality, and purity represented to possess. Specifically, A) Vial sizes used for qualification of visual inspectors are not justified. For example: 1. The qualification kit for [(6) (4)] in a clear vial are [illegible] mL. 2. The qualification kit for [(o) (~)] product [(b) (4)] - the product (both aseptically processed and terminally sterilized) are [(b) (4)]. B) The visual inspection kits, used to qualify inspectors, do not represent all defects that are required to identify. Defect types are limited to: 1. [(6) (4)] in a clear vial: vial not conform (critical), missing stopper (critical), empty vial (major), product on the wall (major), and presence of product on the vial (externally) (major), which are defect types for visual inspection. 2. [(6) (4)] in [(6) (4)] vial: vial not conform (critical), product appearance not conform (major), presence of product on the stopper (major), dirty stopper (major). 3. Solution in clear vial: particles (critical), non conforming (major), product appearance not conforms (major), broken or damaged stopper (major), and dirty stopper (major). C) The visual inspection kits for [(l5) (4)] product do not represent the correct vial size. D) Visual inspectors are required to be able to identify the defect vials during inspection and record the category of defect (such as critical, major, minor) but records do not indicate what specific defect (such as glass, fibers, etc.) was observed for each categorized defect.

    4. Observation 6

      Quality unit oversight deficiencies

      The responsibilities and procedures applicable to the quality control unit are not being followed. Specifically, A) The Quality Unit review of records does not ensure the accuracy of reported data. For example, during filling of [(t5) (4)] interventions [(b) (4)] (adjustment of [(b) (4)]) requiring a Grade A gown monitoring. [(b) (4)] was not the same operator that received the rework. B) A CAPA was not implemented in response to deviation DP0 15/2025 to update the inspection kits for [(o) (4)] drug product to control product on the stopper, which is a major defect.

    5. Observation 7

      Computer/data integrity control lapses

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are documented and that data integrity is maintained. Specifically, Your production and quality unit (QU) did not review electronic raw data or audit trails to ensure data integrity prior to batch release or completion. Your operators obtained and printed passing results for [(b) (4)] or printed the failing results. Impacted production systems included, but were not limited to, the [(b) (6) (4)] Integrity Tester (IN/FI/07), the Grade A and B Integrity Monitor System [(b) (4) IN/PA/07], and the non-viable particle counter (NVPC) [(b) (4)].

    6. Observation 8

      Endotoxin test (LAL) procedure inadequate

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that components and drug products conform to standards of identity, strength, quality and purity. Specifically, The firm's kinetic turbidimetric LAL bacterial endotoxin test procedure for finished products requires the testing of [(b) (4)] containers of finished product in a single test, and found the test procedure deficient in that it did not allow determination of the Maximum Valid Dilution (MVD) of [(b) (4)] sample which can lead to false negative results. Diluting a unit potentially containing harmful levels of endotoxins with other units containing lower, less harmful, levels of endotoxins. The current MVD was not determined by method validation and did not accurately reflect the MVD of the [(b) (4)] sample during routine testing for product release for stability testing. The firm's practice has been since the endotoxin test was first performed by QC.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

14 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Jun 27, 2025Not classified yet

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 7, 2026FDA-FOIA-2026-4678Form 483· 1 of 5 sitesWithdrawn
    2. Nov 14, 2025FDA-FOIA-2025-12940Form 483Records released
    3. Oct 7, 2025FDA-FOIA-2025-11754Form 483· 1 of 2 sitesRecords released
  • Inspection ending Jun 19, 2024

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Jul 1, 2024FDA-FOIA-2024-5735EIRWithdrawn
  • Inspection ending Feb 20, 2023

    6 requests. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-6712EIRMerged with another request
    2. FY2023FDA-FOIA-2023-6711Inspection recordsClosed
    3. FY2023FDA-FOIA-2023-6016Form 483 + EIRClosed
    4. FY2023FDA-FOIA-2023-5465Form 483 + EIRClosed
    5. Feb 23, 2024FDA-FOIA-2024-1984EIRClosed
    6. Feb 23, 2024FDA-FOIA-2024-1983Form 483Closed
  • Inspection date not given

    4 requests. None of FDA’s log entries for these requests say records were released.

    1. Aug 1, 2024FDA-FOIA-2024-6832Form 483Closed
    2. Aug 1, 2024FDA-FOIA-2024-6831EIRClosed
    3. Jun 24, 2024FDA-FOIA-2024-5557Form 483 + EIRClosed
    4. Oct 4, 2023FDA-FOIA-2023-8591EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004762406, one row per refused product line.

1 refusal on 2025-10-29 · charged NOT LISTED on 1, UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2025-10-29

    DASATINIB62ZIY13

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsBUP-1763496-8/10002/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
NerPharMa S.r.lD-U-N-S 338839192

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004762406 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004762406. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.