Florida Institute for Reproductive Sciences and Technologies
2300 N Commerce Pkwy Ste 319, Weston, Florida, United States
FEI 3004516706
FDA has 6 inspections on file for Florida Institute for Reproductive Sciences and Technologies in Weston, Florida (FEI 3004516706), from 2014 to 2025. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Feb 10, 2017. FDA issued a warning letter on (CBER). No court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2014–2025
- 2 OAI · 1 VAI · 3 NAI
- Inspections with 483 observations shown
- 3 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Aug 3, 2026
- Warning letters
- · CBER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Determination based on screening and testing
HCT/P donors were not determined to be eligible based on the results of donor screening and testing.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors of communicable disease agents and diseases.
Ensurane of compliance
You did not ensure that establishment(s) that by contract, agreement or arrangement, perform manufacturing steps for you were in compliance with applicable CGTP requirements prior to the initiation of the contract, agreement of arrangement.
Donor screening standards
Donor screening of HCT/P donors considered eligible indicated that the donor was not free of risk factors for infection due to communicable disease agents.
Documentation--determination, by whom, date
Documentation of the donor-eligibility determination was not maintained.
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood Products11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Specimen collections not timely
Donor specimens used for testing of communicable disease agents were not collected at the appropriate time.
Cell-associated CD
Donors of leukocyte-rich cells or tissues were not tested for cell-associated communicable diseases.
Labeled re: biohazard, risks, test results
HCT/Ps from ineligible donors which were made available for limited use were not prominently labeled with the Biohazard legend and a statement warning of communicable disease risks and a statement warning of the reactive test results .
Responsible person to determine, document
The eligibility of an HCT/P donor was not documented by a responsible person, based on results of donor screening and donor testing.
Donors with risks not determined ineligible
Donors were not determined to be ineligible that had risk factors or clinical evidence of communicable disease agents .
Show 6 more citations
Results, interpretation of CD screening
Documentation of of all donor screening for communicable diseases was not maintained.
Infection with communicable disease agents
Donors were not tested for evidence of infection with communicable disease agents.
Review and approval of procedures
Donor eligibility procedures were not reviewed and approved by a responsible person before implementation.
Documentation--determination, by whom, date
Documentation of the donor-eligibility determination and the date of the donor-eligibility determination was not maintained.
Name and personal info on accompanying records
The accompanying records for HCT/Ps included the donor's name .
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors of communicable disease agents and diseases.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Name and personal info on accompanying records
The accompanying records for HCT/Ps included the donor's name.
Review and approval of procedures
Donor eligibility procedures were not reviewed and approved by a responsible person before implementation.
Risks associated with xenotransplantation
Donors were not screened by a review of relevant medical records for disease risks associated with xenotransplantation.
Documentation--determination, by whom, date
Documentation of the donor-eligibility determination and the date of the donor-eligibility determination was not maintained.
Labeled re: biohazard, risks, test results
HCT/Ps from ineligible donors which were made available for limited use were not prominently labeled with the Biohazard legend, a statement warning of communicable disease risks, and a statement warning of the reactive test results.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Aug 3, 2026. It asked for a Form 483.
Inspection ending Feb 10, 2017OAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Aug 11, 2026. FDAgent holds no copy that FDA posted.
- Aug 3, 2026FDA-FOIA-2026-7386Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?3 of 3
- 21 CFR 1271.75How do I screen a donor?3 of 3
- 21 CFR 1271.47What procedures must I establish and maintain?2 of 3
- 21 CFR 1271.50How do I determine whether a donor is eligible?2 of 3
- 21 CFR 1271.65How do I store an HCT/P from a donor determined to be ineligible, and what uses of the HCT/P are not prohibited?2 of 3
- 21 CFR 1271.80What are the general requirements for donor testing?1 of 3
- 21 CFR 1271.85What donor testing is required for different types of cells and tissues?1 of 3
- 21 CFR 1271.150Current good tissue practice requirements1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · BiologicsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004516706 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004516706. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.