Skip to content

Concord Biotech Limited

1482-1486, Trasad Road, Dholka, Ahmedabad, Gujarat State, India

FEI 3004126703DUNS 916708337

FDA has 5 inspections on file for Concord Biotech Limited in Ahmedabad, Gujarat State, India (FEI 3004126703), from 2012 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

4 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant is CONCORD BIOTECH LIMITED (D-U-N-S 916708337).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2012–2025
0 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
1 of 5
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
4 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Equipment cleaning contamination risk

      Failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the intermediates and API beyond the official or other established specifications. Specifically, During my walkthrough inspection, I observed residues on the agitator and around the walls of a (b)(4) and on the bottom of the (b)(4). According to the logbook your firm performed after use cleaning on 1 (b)(4) and (b)(4) cleaning on [illegible] Active Pharmaceutical Ingredient.

    2. Observation 2

      Inadequate laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, [illegible].

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004126703, one row per refused product line.

4 refusals from 2023-02-08 to 2025-01-06 · charged NOT LISTED on 3, FRNMFGREG on 1 · no FDA sample analysis

FDA firm profile
  • 2025-01-06

    ANTINEOPLASTIC, NEC58DCS99

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    FRNMFGREG 502(o), 801(a)(3); MISBRANDING

    Division of Northeast Imports231-4118126-0/11/1

  • 2023-02-08

    MYCOPHENOLATE MOFETIL (IMMUNOSUPPRESSIVE)64TCS04

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsES9-0005925-6/21/1

  • 2023-02-08

    MYCOPHENOLATE MOFETIL (IMMUNOSUPPRESSIVE)64TCS04

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsES9-0005925-6/11/1

  • 2023-02-08

    MYCOPHENOLATE MOFETIL (IMMUNOSUPPRESSIVE)64TCS04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast ImportsES9-0005919-9/11/1

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
CONCORD BIOTECH LIMITEDD-U-N-S 916708337

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004126703 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004126703. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.