Skip to content

Badrivishal Chemicals & Pharmaceuticals

Gat No. 29, Village Jambwade (Induri), Post Sudumbre, Taluka Maval, Dist. Pune, India

FEI 3004058356

FDA has one inspection on file for Badrivishal Chemicals & Pharmaceuticals in Dist. Pune, India (FEI 3004058356). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.

1 import refusal is filed under this FEI, on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2016
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Import refusals
1 refusal
Import alerts
66-40Red List
Matched on FDA’s firm name and street address

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Document change control weaknesses

      OBSERVATION 1 Appropriate controls are not exercised to assure that changes to documents related to the manufacture of intermediates or APIs are instituted only by authorized personnel. Specifically: 1) Although required by Sections 5.3-5.5 and 5.13-5.14 of SOP QAD/002/01 (eff. 10JAN2016), no registers documenting the original issuance of controlled documents, to include batch manufacturing records, analytical test reports, and analytical worksheets, are maintained; there are no features or mechanisms to distinguish between original and unauthorized re-prints/copies of controlled documents; and there is no means of reconciling the quantity of working copies of each controlled document issued for a given production batch, analysis, or time period. 2) On 16AUG2016, an uncontrolled, serialized stamp was found in the Quality Control (QC) Laboratory. This serialized stamp is used by the QA department to sequentially number pages in controlled equipment laboratory equipment usage logbooks.

    2. Observation 2

      Incomplete or missing laboratory records

      OBSERVATION 2 Laboratory records do not include complete data derived from all tests and examinations necessary to assure compliance with established specifications and standards. Specifically, 1) The review of torn, discarded records recovered from refuse in the plot adjacent to the south/southeast of the facility identified the following: A) In-process test sheet used for sample collection intimation for ® © Crude Stage [26D , dated 14AUG2016. Discrepancies in product name were discovered upon comparison to that reported on the official version of the corresponding record. B) Form QCD-F-00-059, Analytical Test Report of in-process material, and analytical worksheet corresponding to testing conducted according to STP/IPQC/S) /02/00, issued on 07JUN2016. Official versions of the corresponding records consist of appearance and moisture content test data for Batch [ of 0 following Step & C) Analytical test report of finished API ®@ Batch ®®@ , dated 14APR2016. Discrepancies in hand-written entries for solubility testing for the batch were identified upon comparison to the values reported on the official version of the corresponding record. D) Analytical worksheet dated March 20, 2016, consisting of hand-written calculations for residue on evaporation and microbiological test results. E) Form QCD-F-006-00, Analytical Test Report of ®@ Water corresponding to Analytical Report ©/514/2015-16, issued on 20MAR2016. The official version of the corresponding test report consists of data for the 20MAR2016 ® water sample from ®@ stating that “The Sample complies with Inhouse Specification”. Review of the “potable water Inward Register”, Registry QCD-R-003-00, identifies a single ®® water sample from ®® received and analyzed by QC on 20MAR2016 as “Not OK”, yet the fragment of an additional hand-filled copy of the analytical report for a®® water sample from ®® also issued on 20MAR2016 was recovered from the refuse. F) Water testing results for samples collected from sample point ®® on 30MAR2016 and analyzed on 04APR2016. G) Form QCD-F-006-00s, Analytical Test Report of ®@ /Potable Water, corresponding to Analytical Reports ®#/069/2016-17 and PTW/009/2016-17, completed on 09APR2016. Fragments of numerous copies of Analytical Test Reports consisting of original, hand-written test data were recovered from refuse, two of which with similar tear patterns identify analyses completed on 09APR2016 by the same analyst. One of the two fragments documenting analysis on 09APR2016 indicated that results did not comply while the other indicated compliance with specifications. A third, undated and unsigned fragment of what appeared to be the same Analytical Test Report with the same tear pattern contains hand-written data but no determination of compliance. Formatting of the official version of A.R. ®#/069/2016-17 for ®@ water testing from the firm’s ®@ on 09APR2016 is consistent with the discarded fragments indicating analysis on 09APR2016 and compliance with specifications. H) Form QCD-F-006-00, Analytical Test Report of ®® Water, and analytical worksheet for testing from sample point ®“® , completed 30MAY2016. The official version of Analytical Test Report ®@/203/2016-17 consists of data for the 30MAY2016 ® water sample from ®@. Values from the visible portions of the analytical results for pH, Ammonium, and Residue on Evaporation testing differ between the discarded and official versions of A.R. ®@/203/2016-17. I) Temperature and Relative Humidity Records for Control sample room for the month of July 2016. Discrepancies in relative humidity entries were discovered when comparing the values reported on the official record and the discarded record found in the trash area. J) Form QCD-F-009-01, "Calibration Record of Shimadzu Balance QCD/WB/01, for August 2016." The corresponding version observed in use at the time of inspection of the QC lab documents standard weight calibrations conducted 04-16AUG2016. Fragments of two pages of the Form QCD-F-009-01

      Shortened here; the PDF has the full text.

    Show observations 3 to 9
    1. Observation 3

      Inadequate laboratory control/validation

      OBSERVATION 3 Laboratory control mechanisms are not scientifically sound and appropriate to ensure that raw materials, intermediates, and APIs conform to established standards of quality and/or purity. Specifically, 1) Growth promotion testing of media prepared in-house is routinely performed using a single test organism rather than according to compendial requirements. For example, ®® plate Batch [ ] was used to perform microbial enumeration tests and testing for the presence of a variety of specific pathogens for water system validation samples collected on 07MAR2016. Yet growth promotion testing of Batch ®@ was performed using an inoculum of Salmonella abony (6017 NCTC) only. 2) The temperature of media is not monitored during media batch preparation. 3) Actual temperatures of the 20-25°C incubator used for fungal plate incubation, equipment ID MIC/INC/01, and the [illegible] °C incubator used for E. coli test plate incubation, equipment ID MIC/INC/03, are not recorded.

    2. Observation 4

      Insufficient computerized system access controls

      OBSERVATION 4 Computerized systems do not have sufficient controls to prevent unauthorized access or changes to data. Specifically, unique user identifications have not been established for computerized systems used in the QC Laboratory. All personnel share the “Administrator” user name and password to log into and perform commercial release testing using chromatographic instrumentation. Furthermore, the “Administrator” user has unrestricted system and software privileges that allow for the deletion, modification and alteration of raw chromatographic data.

    3. Observation 5

      Test execution not properly documented

      OBSERVATION 5 Test procedures are not fully documented at the time of performance. Specifically, 1) On 12JUN2016, five (5) injection sequences were performed for ®© solvent testing on Gas Chromatography instrument GC-01 corresponding to the following data files: 001.rslt, 002.rslt, 003.rslt, 005.rslt, and 007.rslt. However, the running of these sequences for unidentified batches of raw material was documented in the equipment usage logbook for GC-01. 2) Review of chromatographic source data identified sequences for impurity testing of ®® run on 02FEB2015, 21FEB2015, 26SEP2015, and 06JAN2016. However, the running of these sequences for various batches of finished drug substances was not documented in the equipment usage logbooks for HPLC-01. 3) Review of the analytical worksheets for microbiological testing in support of the ®® Water system performance qualification (samples collected from 07MAR-05APR2016) identified numerous failures to document the batch #’s of media used for pathogen testing and analysts and secondary officials responsible for test execution and review, respectively.

    4. Observation 6

      Missing compendial method verifications

      OBSERVATION 6 Complete records documenting the suitability of compendial test methods are not maintained. Specifically, compendial method verification studies are not available for residual solvent, impurity, and microbiological test methods used for the testing and release of commercial batches of ® , USP, drug substance by an off-site, contract testing laboratory.

    5. Observation 7

      Inadequate OOS investigations

      OBSERVATION 7 Out-of-specification results are not thoroughly investigated in that assessments of whether significant problems exist, allocation of the tasks for corrective actions, and conclusions are not documented. Specifically, no investigations or determination of root causes for the two (2) out-of-specification (OOS) results generated in 2015 and 2016 were documented. These two (2) OOS results for rejected raw material batches consist of the following: + 008/001/2016-17 - for raw material Batch®® , dated 11JUN2016, for appearance/description; + OOS/001/2015-16 for ®@@ raw material Batch®?® , 03AUG2015, for loss-on-drying.

    6. Observation 8

      Unsuitable/poorly controlled water system

      OBSERVATION 8 Water used in the manufacture of APIs has not been demonstrated to be suitable for its intended use. Specifically, 1) Installation and operational qualification of the current ®® water system was completed in December 201[illegible] and the system has been in continuous use for manufacturing and cleaning activities since then. However, performance qualification of the ®@ water system was not initiated until 16 months later, with initiation of Validation Protocol VP/PFD-02/001/00 on 07MAR2016. 2) Source water emanates from a nearby river (~1km from the facility), and is not subjected to governmental testing for potability. No microbiological testing of source water from the primary storage tank is performed to verify its suitability according to World Health Organization (WHO) guidelines for potability. 3) Validation Protocol VP/PFD-02/001/00 requires no microbiological testing of source water to evaluate the total coliform load introduced to the water purification system or to demonstrate effective reduction of total coliform loads throughout seasonal variations. 4) During execution of the initial phase of the [illegible] water system performance qualification (07MAR- [illegible]) samples from all points [illegible] failed to meet acceptance criteria for microbial load of water. Additionally, samples from [illegible] also failed to meet acceptance criteria for chemical characteristics of ®® water. However, the interim Validation Report VR/PFD-02/001/00 (eff. 11APR2016) states that chemical and microbiological test results were within acceptance criteria for all sample points during the initial phase of validation. 5) Per SOP MTN/004/00 (eff. 01OCT2015), sanitization of the water system is to be performed [illegible]. A) Review of the most-recent sanitization cycle run 15AUG2016, documented on Form MTN-F-005-00, identified maintenance of the sanitizing [illegible] for 15 min. instead of the [illegible] required. Further review of the documentation of sanitization cycles run since January 2016 identified maintenance of the sanitizing [illegible] for less than the [illegible] required on eight (8) different occasions. Additionally, no sanitization cycle was documented between 11JAN and 26FEB2016. As of the time of inspection, no deviation was initiated for these excursions from SOP MTN/004/00. B) Following sanitization, the ®® water storage tank and distribution loop are to be [illegible] and at that time sampled from the [illegible] of the ®® water. From January 2016 to present, routine ®® water microbiological sampling coincides with the frequency for ®® water system sanitization on 2 occasions (11JAN and 02MAY2016). As such, sampling from ®® immediately following the sanitization cycle was not truly representative of the microbial quality of ®® water used in manufacturing and cleaning activities over the periods of 11JAN2016 and 02MAY2016. 6) SOP QCD/003/00, "Standard Operating Procedure for Sampling and Chemical Analysis of Potable Water and ®@ Water" (eff. 28JUN2013), requires water samples to be collected from the user points located the production area. However, all water samples collected for chemical and microbiological analysis prior to March 2016 were sampled solely from the ®@ of the ®® water, sampling point ®®. 7) The ®@ water storage tank used to collect, pool, and re-circulate ® water to points-of-use throughout the API production area is not equipped with a vent filter. Upon inspection, a gap was observed between the tank housing, its gasket, and its manhole cover with fasteners missing from the cover. The interior of the water storage tank was directly exposed to the surrounding, uncontrolled environment through the gap, and condensation was observed settling along the interior rim of this gap. 8) The in-line conductivity and flow meters used to monitor the conditions of the ®® water system are not routinely calibrated. Furthermore, there is no SOP describing the usage of or established ac

      Shortened here; the PDF has the full text.

    7. Observation 9

      Inadequate handwashing facilities

      OBSERVATION 9 Adequate, clean washing and toilet facilities are not provided for personnel. Specifically, soap or detergent and air driers or single service towels are not provided at hand or foot washing facilities used by manufacturing personnel immediately prior to gowning and entry into production areas with open, exposed toe sandals.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004058356, one row per refused product line.

1 refusal on 2017-02-15 · charged DRUG GMPS on 1 · no FDA sample analysis

FDA firm profile
  • 2017-02-15

    CATHARTIC N.E.C.63HBY99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Northeast ImportsAVV-1612126-4/11/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2016-12-19

    FDA’s entry
    Badrivishal Chemicals & Pharmaceuticals · Gat No. 29, Village Jambwade (Induri), Post Sudumbre, Taluka Maval, Dist. Pune, INDIA
    FDA’s inspection record for FEI 3004058356
    Badrivishal Chemicals & Pharmaceuticals · Gat No. 29, Village Jambwade (Induri), Post Sudumbre, Taluka Maval, Dist. Pune, India

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    10 products

    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    Show 7 more products
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004058356 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004058356. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.