Skip to content

People's Pharmacy, Inc

4018 N Lamar Blvd, Austin, Texas, United States

FEI 3003987288

FDA has 2 inspections on file for People's Pharmacy, Inc in Austin, Texas (FEI 3003987288), from 2014 to 2017. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Dec 22, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below.

The most recent OAI inspection ended on Nov 18, 2014. No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2014–2017
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Use of non-pharmaceutical grade components

      OBSERVATION 1 Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. For example, a) Your firm uses [illegible] water in certain drug products whose formulation requires water. Your firm is also using the [illegible] water to make [illegible] Water [illegible] for use in certain drug products. Your firm has no documentation of any testing performed (analytical or microbiological) to show the water at least/at minimum meets the specifications for Purified Water, USP. Examples of products made using the [illegible] water include lot #09082017@10 of Clonidine (Grape Simple Syrup) 0.1 mg/mL Suspension and lot #11012017@21 of Clonidine (Strawberry/Marshmallow Simple Syrup) 0.1 mg/mL Suspension. Examples of lots made using the [illegible] Water made from the [illegible] water include lot #11302017@33 of Tranexamic Acid 5% Solution and lot #11212017@32 of Dexamethasone/Gentamicin/Itraconazole 0.1%/80 mg/100 mg/30 mL Nasal Spray. b) Your firm uses Acetone CP grade for making drug products. The Acetone is labeled for "technical use only". In the past 6 months, your firm made [illegible] of drug product using the Acetone CP - lot #10062017@10 of Squaric Acid (In Acetone) 0.1% Solution.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003987288 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003987288. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.