Diamond Institute for Infertility and Menopause
89 Millburn Ave, Millburn, New Jersey, United States
FEI 3003945103
FDA has 8 inspections on file for Diamond Institute for Infertility and Menopause in Millburn, New Jersey (FEI 3003945103), from 2009 to 2023. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
FDA published one citation from this inspection, under 21 CFR Part 1271, the rules for human cell and tissue products. It is listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 8, 2009–2023
- 0 OAI · 4 VAI · 4 NAI
- Inspections with 483 observations shown
- 5 of 8
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Jul 7, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors of communicable disease agents and diseases.
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Listing and interpretation of CD tests performed
The summary of records for HCT/Ps did not contain a listing and an interpretation of results of all communicable disease tests performed.
Shipped but not kept in quarantine
HCT/Ps shipped prior to the completion of the donor-eligibility determination were not kept in quarantine during shipment.
Testing, screening, donor eligibility procedures
You did not establish and maintain procedures for screening of HCT/P donors.
Reactive tests--not determined ineligible
Donors whose specimens test reactive on screening tests for communicable disease agents were not determined to be ineligible.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors of communicable disease agents and diseases.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Nonclinical use--label requirements
HCT/Ps from ineligible donors which were made available for nonclinical use were not labeled "For Nonclinical Use Only".
Name and personal info on accompanying records
The accompanying records for HCT/Ps included the donor's name and personal information that might identify the donor.
Testing, screening, donor eligibility procedures
Procedures for all steps performed in the testing, screening and determining of donor eligibility of HCT/Ps were not established, maintained, defined, documented, implemented and followed.
SOP for release; reactive for CMV
A standard operating procedure for the release of HCT/Ps from donors that test reactive for cytomegalovirus (CMV) was not followed.
Design of procedures to ensure compliance
Procedures were not designed to ensure compliance with the donor eligibility requirements.
Show 6 more citations
Specimen collections not timely
Donor specimens used for testing of communicable disease agents were not collected at the appropriate time.
Reasons for ineligibility on summary
The summary of records for HCT/Ps from donors determined to be ineligible based on screening and released for limited use did not contain a statement noting the reasons(s) for the ineligibility.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors and clinical evidence of communicable disease agents and diseases.
Review and approval of procedures
Donor eligibility procedures were not reviewed and approved by a responsible person before implementation.
Responsible person to determine, document
The eligibility of an HCT/P donor was not determined and documented by a responsible person, based on results of donor screening and donor testing.
Statement re: certified testing lab
The summary of records for HCT/Ps did not contain a statement that the communicable disease testing was performed by a laboratory certified to perform such testing on human specimens under the Clinical Laboratory Improvement Act of 1988 or has met equivalent requirements determined by the Centers for Medicare and Medicaid Services.
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Donors with risks not determined ineligible
Donors were not determined to be ineligible that had risk factors or clinical evidence of communicable disease agents.
Testing, screening, donor eligibility procedures
Procedures for all steps performed in the screening and determining of donor eligibility of HCT/Ps were not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for all other requirements
Procedures for all steps performed in the testing, screening, and determining of donor eligibility of HCT/Ps were not established, maintained, defined, documented, implemented, followed, and reviewed.
Infection with communicable disease agents
Donors were not tested for evidence of infection with communicable disease agents.
Specimen collections not timely
Donor specimens used for testing of communicable disease agents were not collected at the appropriate time.
Abbreviated procedure
The abbreviated donor screening procedure was used for donors who had no complete donor screening procedure in the previous six months.
Responsible person to determine, document
The eligibility of an HCT/P donor was not determined by a responsible person, based on results of donor screening and donor testing.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jul 7, 2026. It asked for a Form 483.
Inspection ending Feb 22, 2023NAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 21, 2026. FDAgent holds no copy that FDA posted.
- Jul 7, 2026FDA-FOIA-2026-6463Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 1271.75How do I screen a donor?5 of 5
- 21 CFR 1271.47What procedures must I establish and maintain?4 of 5
- 21 CFR 1271.80What are the general requirements for donor testing?3 of 5
- 21 CFR 1271.50How do I determine whether a donor is eligible?2 of 5
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?2 of 5
- 21 CFR 1271.85What donor testing is required for different types of cells and tissues?2 of 5
- 21 CFR 1271.60What quarantine and other requirements apply before the donor-eligibility determination is complete?1 of 5
- 21 CFR 1271.65How do I store an HCT/P from a donor determined to be ineligible, and what uses of the HCT/P are not prohibited?1 of 5
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003945103 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003945103. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.