Muasher Center for Fertility and IVF, dba Partners for Fert.
8100 Boone Blvd Ste 430, Vienna, Virginia, United States
FEI 3003937760
FDA has 3 inspections on file for Muasher Center for Fertility and IVF, dba Partners for Fert. in Vienna, Virginia (FEI 3003937760), from 2010 to 2014. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 7 citations from this inspection, all under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 1271.55(a)(2).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2010–2014
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reproductive cells/ tissues- general
Donors of reproductive cells or tissues not recovered by a method that ensures freedom from contamination were not screened by a review of relevant medical records for clinical evidence of communicable diseases of the genitourinary tract.
Kits not FDA approved, specifically labeled
Communicable disease agent tests were not FDA-licensed, approved or cleared donor screening tests.
Statement re: certified testing lab
The summary of records for HCT/Ps did not contain a statement that the communicable disease testing was performed by a laboratory certified to perform such testing on human specimens under the Clinical Laboratory Improvement Act of 1988 or has met equivalent requirements determined by the Centers for Medicare and Medicaid Services.
SOP for release; reactive for CMV
A standard operating procedure for the release of HCT/Ps from donors that test reactive for cytomegalovirus (CMV) was not followed.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors and clinical evidence of communicable disease agents and diseases.
Show 2 more citations
Eligibility statement--basis of determination
After the completion of the donor-eligibility determination, HCT/Ps were not accompanied with a statement whether the donor has been determined to be eligible or ineligible, based on the results of screening and testing.
Procedures for all other requirements
Procedures for all steps performed in the determining of donor eligibility of HCT/Ps were not established.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Responsible person to determine, document
The eligibility of an HCT/P donor was not determined by a responsible person, based on results of donor screening and donor testing.
Listing and interpretation of CD tests performed
The summary of records for HCT/Ps did not contain an interpretation of results of all communicable disease tests performed.
Name and personal info on accompanying records
The accompanying records for HCT/Ps included personal information that might identify the donor.
Eligibility statement--basis of determination
After the completion of the donor-eligibility determination, HCT/Ps were not accompanied with a statement whether the donor has been determined to be eligible or ineligible, based on the results of screening and testing.
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?2 of 2
- 21 CFR 1271.47What procedures must I establish and maintain?1 of 2
- 21 CFR 1271.50How do I determine whether a donor is eligible?1 of 2
- 21 CFR 1271.75How do I screen a donor?1 of 2
- 21 CFR 1271.80What are the general requirements for donor testing?1 of 2
- 21 CFR 1271.85What donor testing is required for different types of cells and tissues?1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003937760 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003937760. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.