Skip to content

Symrise, S. de R.L. de C.V.

Av. Republica Mexicana 200, Col. Garza Cantu, San Nicolas De Los Garza, Mexico

FEI 3003722350DUNS 812803724

Company: Symrise, Inc. · Linked by exact D-U-N-S match (135173420) in FDA registration data

FDA has 2 inspections on file for Symrise, S. de R.L. de C.V. in San Nicolas De Los Garza, Mexico (FEI 3003722350), from 2018 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Three of the five FOIA requests for this site have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Symrise, Inc. (D-U-N-S 135173420), has registered 4 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2018–2025
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Requested under FOIA
5 requests, latest FY2023
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Quality Unit document control

      Lack of Quality Unit oversight and control of documents. Specifically, A) There is a lack of control over the issuance of batch and production control records used to document the manufacturing of the drug products (b)(4) (b)(4) B) The instrument identification numbers used in the analysis of APIs are not documented in the batch records or analytical data results in MYSAP. C) QC analysts have the ability to delete raw chromatographic data files in the Total Chrome software.

    2. Observation 2

      Missing production/process procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, you do not have written procedures for: 1) Labeling procedures of finished products 2) Shipping of crude (b)(4) to (b)(4) and the QC release and return of the finished API (b)(4) 3) The QC release based on Certificate of Analysis for the raw materials (b)(4) Powder and (b)(4) (b)(4) 4) User rights and privileges of instrument software, such as Total Chrome.

    Show observations 3 to 5
    1. Observation 3

      Process validation not conducted

      Failure to conduct process validation on the drug manufacturing process. Specifically, you did not validate the number of times the (b)(4) process step may be repeated for the active pharmaceutical ingredient (API) (b)(4). In addition, you do not document the number of times the (b)(4) is repeated in the batch production records form, FO-MX-0356 Rev 1 (b)(4) batch record code (b)(4) Rev 0, effective date 7-May-2018.

    2. Observation 4

      Deficient batch/control records

      The batch production and control records are deficient in that they are not an accurate reproduction of the appropriate master production or control record. Specifically, A) The production batch records for the APIs (b)(4) do not include a description and documentation of the accomplishment of each process step in the manufacturing of the finished API B) A non-conformance was not opened by the Chemical Production regarding holding of a drug product in the production of (b)(4) Lot [illegible]

    3. Observation 5

      Inadequate laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate standards, sampling plans, and test procedures designed to assure that in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, A) The limit of the product residuals stated in the cleaning validation protocol IPVL-EP, Protocolo de Validacion de Limpieza de Equipos, Rev. 1 effective date 7-Mar-2018, was not based on scientifically sound evidence. A justification for the limit of [illegible] ppm was not provided upon request. B) The decisions to perform [illegible] calibrations on the analytical balance (SIN 15103151) and (b)(4) calibrations on the PerkinElmer Clarus 680 GC (SIN 680S1412 1501) located in the QC Laboratory were not based on scientifically sound and documented evidence.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending May 23, 2025VAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 8, 2025. FDAgent holds no copy that FDA posted.

    1. Sep 26, 2025FDA-FOIA-2025-11319Form 483· 1 of 3 sitesRecords released
    2. Sep 17, 2025FDA-FOIA-2025-11045Form 483· 1 of 2 sitesRecords released
    3. Aug 1, 2025FDA-FOIA-2025-9331Form 483· 1 of 3 sitesWithdrawn
  • Inspection ending Sep 21, 2018VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. May 22, 2025FDA-FOIA-2025-4618Form 483Closed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-2391Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Symrise, Inc.D-U-N-S 135173420

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Symrise, Inc. (D-U-N-S 135173420) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Reactimex, SA de C.V.Monterrey, Mexico · FEI 30001866292 inspections2latestMay 29, 2025VAINone on file
  • Symrise, Inc.Goose Creek, South Carolina · FEI 10496795 inspections5latestFeb 28, 2025VAINone on file
  • Symrise AGHolzminden, Germany · FEI 30030385134 inspections4latestDec 5, 2023VAINone on file
  • Vizag Care Ingredients Private LimitedParavada Visakhapatnam, India · FEI 3040483155Registered; no FDA inspection on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3003722350 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3003722350. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.