New England Compounding Pharmacy, Inc.

697 Waverly St, Framingham, Massachusetts, United States

FEI 3003623877

FDA has one inspection on file for New England Compounding Pharmacy, Inc. in Framingham, Massachusetts (FEI 3003623877). It ended on and was classified NAI, no action indicated. FDA has also posted a Form 483 dated Jul 24, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
1, in 2012
Inspections with 483 observations shown
1 of 1
3 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality Assurance2 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 4

      Environmental monitoring not investigated

      4. The environmental monitoring procedure requires sampling via personnel touch plates to compounding and prior to cleaning. Records from January thru September 2012 the following results inside production hoods: Table #1: Clean Room 1 and Clean Room 2 Date Isolates 1/3/12 OG with bacteria 4/12/12 OG with bacteria 6/15/12 1 bacteria, 1 mold 6/21/12 2 bacteria 7/2/12 1/2 plate OG with bacteria 7/19/12 1 bacteria, 2 molds 7/31/12 2 bacteria 8/16/12 2 bacteria Note: OG indicates over growth These results were not investigated and there was no identification of the isolates. There were performed for any sterile products that were made in the hoods or gloveboxes on the the firm has no evidence that any corrective actions were taken to prevent contamination

    2. Observation 5

      Facility cleanliness and contamination risks

      5. The conditions listed below were identified during the inspection in areas used for the preparation, filling, and/or storage of sterile drugs products. • On 10/04/2012, we observed greenish yellow discoloration lining the interior surface of the "Inside" autoclave, located in the firm's Middle Room (ISO 7). This autoclave is used for the steam sterilization of various components and equipment (e.g. vials of multiple sizes, stoppers, and spin bars) used in the formulation of sterile drug products. • On 10/04/2012, we observed what appeared to be tarnished discoloration on the interior surfaces (e.g. trays) of the "Outside" autoclave located in the firm's [illegible]. Condensation along the interior surfaces of the "Outside" autoclave was observed to collect in a pool at the base of the chamber. This is one of two tabletop autoclaves used for steam sterilization of various components and equipment used in the formulation of sterile drug products. • The firm is abutted to the rear and along the left parking area by a recycling facility that handles mattresses and plastics. On 10/02/2012, the area was observed to include large trucks producing airborne particulates (e.g. dust). The recycling facility appears to be located approximately 100 feet from the firm. • On 10/04/2012, we observed what appeared to be [illegible] on louvers of an HVAC return located behind the [illegible]. This autoclave is used for the steam sterilization of formulated bulk drug suspensions, including preservative-free formulations of methylprednisolone and triamcinolone, which are intended for injection. • On 10/02/2012 and 10/04/2012, we observed yellow residue and greenish residue lining the rear return of Weigh Station 3 Hood, both located in the firm's ISO 6 Clean Room. The firm uses Weigh Station Hoods to weigh active ingredients and other raw materials utilized in the formulation of sterile drug preparations. • On 10/04/2012, we observed greenish residue covering the surface filter above, within Weigh Station 3 Hood located in the ISO 6 Clean Room. • On 10/04/2012, we observed what appeared to be tarnished discoloration on the interior surfaces (e.g. trays) of the autoclave located in the firm's Prep Room (ISO 8). This autoclave is used for steam sterilization of components (e.g. beakers, spoons) used in the formulation of sterile drug products. • On 10/04/2012, a boiler installed within approximately 30 feet was observed to be leaking water into puddles. Moreover, wet floor surfaces around the boiler appeared to contain debris and thick black, granular material. Gaps were observed between the boiler and the Prep Room (ISO 8) and being fully closed. This room is used for [illegible] equipment and includes the [illegible]. • On 10/02/2012, the tacky mat located within the entrance of the Prep Room (ISO 8), at the transition to the warehouse, was observed to be brown and soiled. This room is used for the preparation of [illegible] for the preparation of equipment and includes the [illegible]. • On 10/04/2012, we observed cloudy discoloration on metal surfaces within the "Pass Thru," installed within the wall of the ISO 6 Clean Room, was observed to contain reddish [illegible]. The ISO 6 Clean Room is used to formulate and fill sterile preparations, including methylprednisolone. • On 10/04/2012, we observed what appeared to be dark, hair-like discoloration along the bottom edge of the closed pass through installed within the wall of the ISO 6 Clean Room to formulate and fill sterile preparations, including methylprednisolone.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003623877 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003623877. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.