Hetero Drugs Limited
Unit I, Sy. No. 213, 214 & 255, Bonthapally Village, Gummadidala Mandal, Sangareddy, India
FEI 3003510514DUNS 650433076
Company: Hetero Drugs Limited · Linked by exact D-U-N-S match (650220163) in FDA registration data
FDA has 6 inspections on file for Hetero Drugs Limited in Gummadidala Mandal, Sangareddy, India (FEI 3003510514), from 2010 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, Hetero Drugs Limited (D-U-N-S 650220163), has registered 3 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2010–2025
- 0 OAI · 4 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 6
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate OOS results
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. OOS investigation OOS-HDL1-17-053 was initiated on 08/10/2017 and closed on 08/11/2017 for Batch No: [illegible] where it was found out-of-specification for water content by Karl Fischer (KF) replicate -1 (75 % w/w and the specification [illegible]). However, the firm did not extend the investigation to manufacturing.
- Observation 2
Quality unit supplier qualification failures
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your Quality Unit failed to qualify and perform routine audits of multiple suppliers of computer software used for the GxP computerized systems (Empower 3 Software and Laboratory Information Management System or LIMS) used as data acquisition systems in the testing of raw materials, in-process testing, and API finished materials, and Warehouse Management Portal System (WMPS) used as the inventory management system in your facility as required per Step 20 (Supplier Assessment) of SOP #01-043-00 (Computerized Systems Validation Master Plan) 11/01/2013 effective date. For example, the firm accepted the validation documents of the supplier (Empower 3 Software) and failed to qualify that supplier, LIMS and WMPS suppliers, and has not performed a periodic evaluation of Empower 3 Software.
Show observations 3 to 5
- Observation 3
Insufficient employee training and knowledge
Employees engaged in the processing, holding, and testing of a drug product lack the training and experience required to perform their assigned functions. Specifically, during the walk-through of the Production on 02/26/2018 and QC Laboratory on 02/27/2018, I noticed that several QC personnel interviewed in Unit-I could not explain their assigned functions and processes after repeated opportunities. These personnel are trained based on the review of their training records. A. The Deputy Manager for Production could not fully explain what actions to be taken if metals are found in the [illegible] located in Room WB where product is manufactured as part of his assigned functions although he was asked both in native’s tongue Telugu and English. He worked on [illegible] batch [illegible] for the US Market on 03/12/17 and dispatched on 03/18/2017. B. The Deputy Manager of Pharma Storage could not explain the staging process of finished materials awaiting QA Release in the Pharma Storage when interviewed although he was asked both in native’s tongue Telugu and English. He performed the operation for [illegible] finished API materials Lots dispatched to US Market on 01/09/2017. C. The Assistant Manager QC responsible for receiving finished API materials samples and performing samples of these finished API materials could not fully explain the samples process and cleaning although he was asked both in native’s tongue Telugu and English. He performed the operation for Lot #7 on 01/24/16 and dispatched to US Market on 08/16/2016. D. The Executive QC in the Instrumentation Laboratory could not explain how to operate and standardize the Malvern Mastersize equipment ID #QCD/225, which he used on 11/24/17 for testing Lots dispatched to US Market on 11/30/2017. E. The Deputy Manager HR #98 could not explain how to synchronize analog clocks used in the manufacturing operations and was the author of SOP #55-006-01 (Synchronization of Analog Clocks) 02/22/2018 effective date and the "checked by" person of SOP #55-006-00 (Synchronization of Analog Clocks) 04/05/2014 effective date. F. The Sr. Executive Production could not explain what actions to be taken if critical step timing is not met. For example, he was asked if the critical step parameters exceeded the parameter what he would need to do. He stated "if gone over the limit, no problem. However, if gone below the limit, appropriate personnel would be notified and a deviation be raised.",
- Observation 4
Equipment cleanliness and maintenance issues
There is no assurance that the equipment used in the production of the API are always maintained and/or kept in/under proper conditions for manufacturing operations and to prevent the contamination of the products handled and/or processed in the equipment. The following conditions were observed on 02/26/2018, during the walk-through the production areas in Unit-I Block (used to produce [illegible]): A. Inside of [illegible] M001 for the process was observed dirty (i.e. The gloves used by the Investigator showed a color/stains of the inner surface of the [illegible] which is used to manufacture products destined for US Market.
- Observation 5
Glassware storage and contamination risk
Separate or defined areas to prevent contamination or mix-ups are deficient regarding laboratory controls and operations. Specifically, the glassware storage area in your Microbiology laboratory is not well-maintained. Cleaned glassware including vials, flasks, pipettes, etc. were stored uncovered in close proximity to other unclean glassware, cleaning supplies, and the washing sink, which is contrary to Step #2 of SOP #60-018-01 (Cleaning and Sterilization of Glassware) 08/21/2017 effective date. Additionally, the cleaned glassware was not labeled with current cleaning status.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Hetero Drugs LimitedD-U-N-S 650220163
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Hetero Drugs Limited (D-U-N-S 650220163) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Hetero Drugs LimitedHyderabad, India · FEI 30093076111 inspection1latestJan 27, 2023NAINone on file
- Hetero Drugs LimitedAnakapalli, India · FEI 30092253863 inspections3latestJun 21, 2022VAINone on file
- Hetero Drugs LimitedMedak District, India · FEI 30094883731 inspection1latestSep 15, 2017NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003510514 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003510514. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.