Med Prep Consulting, Inc.
1540 W Park Ave Ste 5, Ocean, New Jersey, United States
FEI 3002902471
FDA has 2 inspections on file for Med Prep Consulting, Inc. in Ocean, New Jersey (FEI 3002902471), from 2009 to 2013. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Jul 11, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 12 observations from the PDF; they are listed below.
FDA issued a warning letter on (CDER). FDA's compliance record also lists one other action under this FEI: Injunction, . No import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2009–2013
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 2
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate product discrepancies
QUALITY SYSTEM OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. A. Your firm's complaint files indicate that within the last twenty-four months your firm incorrectly compounded, incorrectly labeled, or incorrectly packaged approximately 20 injectable drug products. You released and distributed those products and then needed to retrieve them from your customers for destruction or re-labeling. A thorough investigation was not conducted and corrective and preventative actions were not implemented or documented. Some examples from 2012 include: 1. A label control error resulted in a pre-filled syringe of Zosyn with 3.375 grams of active ingredient being incorrectly labeled to contain only 2.25 grams of the active ingredient (LOT: 1002127CCH USE BY: 11/01/2012). The firm's customer noticed the volume difference in the syringe, and this super-potent drug product was returned and destroyed. 2. A label control error resulted in pre-filled syringes of Aztreonam with 2.0 grams of the active ingredient in 10 mL of Sterile Water For Injection being incorrectly labeled to contain only 1.0 gram of the active ingredient (LOT 0327121BCH, USE BY: 06/25/2012). The firm's customer noticed the difference in the purchase order and this super-potent drug product was returned, re-labeled with the correct dosage strength, and re-shipped. 3. A label control error resulted in IV bags of Magnesium Sulfate Injection with 2.0 grams of the active ingredient being incorrectly labeled to contain only 1.0 gram of the active ingredient (LOT 0326121118 USE BY: 05/10/2012). The firm's customer noticed the purchase order discrepancy and this super-potent drug product was returned, re-labeled with the correct formulation, and re-shipped. 4. A label control error resulted in pre-filled syringes Zosyn 2.25 gram in sterile water being incorrectly labeled as Zosyn 2.25 gram in 5% Dextrose (LOT 0117129CCH USE BY: 02/16/2012). The firm's customer noticed the mistake and this drug product was returned, re-labeled with the correct formulation, and re-shipped. 5. A secondary packaging error resulted in light sensitive drug product, IV bags of Bupivacaine, 0.5% Epinephrine 1:200,000 Normal Saline, not being packaged in the correct protective bags (LOT 1008127R USE BY: 10/28/2012). The firm's customer noticed the mistake and drug product was returned and destroyed. 6. IV bags of Gentamicin, 80 mg in 25 mL of 0.9% NaCl, a frozen drug product, were shipped without temperature controls (LOT 06191210YNHMC, USE BY: 07/19/2012). This temperature abused drug product was returned and destroyed. B. Investigations into product sterility and environmental monitoring test failures are not documented. Additionally, investigations into failing performance challenges do not include the evaluation of product impact. C. You have your employees conduct a performance challenge of their aseptic technique on a daily basis by having them use media at the end of a processing run using the tailings of the drug product and the same container closure system that they just finished processing. Since 2011, there were at least 20 failed employee performance checks recorded after employees processed injectable drug products such as Heparin, Avastin, Oxytocin, and Norepinephrine. Contaminated aseptic performance check samples were analyzed and organisms such as bacteria (Staphylococcus sp. and Bacillus sp.) and mold (Penicillium spp) were identified. Your investigations into the failed performance checks did not evaluate the possible impact on the finished drug products. 2. Your microbiological testing identified at least seven drug products in the last 26 months that had either turbid broth or particle matter floating in injectable drug products such as Lidocaine, Bevacizumab, Heparin and Famotidine. Although re-test results are docu
Shortened here; the PDF has the full text.
- Observation 2
Inadequate laboratory testing controls
LABORATORY SYSTEM OBSERVATION 2 Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, your firm produces approximately [illegible] lots of injectable drug products per day and does not perform the following testing: A. Assay or product identification testing for any sterile injectable drug product produced. B. Sterility testing for all acts produced is not performed. Less than 100% of the injectable drug products are tested for sterility per day ([illegible] lots, on average) and those drug products are tested using non-compendial methods that have not been validated to demonstrate that they are at least as good as the compendial methods. The written test method for the in-house steril[ity] include the quantity of drug product to be tested. In addition, there is no assurance the media, [illegible], is capable of detecting all growth. C. Endotoxin testing data for any lot of sterile injectable drug product produced. D. Antimicrobial effectiveness testing to support drug product "Use By" dates for sterile drug products containing preservatives. The firm processes approximately [illegible] drug products with preservatives. For example, Oxytocin, which is labeled with a "Use By" date of 45 days after the date of preparation.
Show observations 3 to 13
- Observation 3
Insufficient stability/expiration testing
OBSERVATION 3 An adequate number of batches of each drug product are not tested to determine an appropriate expiration date. Specifically, you produce approximately 113 injectable drug products, including the different packaging sizes and containers (IV bags or pre-filled syringes). For 94 of those drug products, you relied exclusively on literature searches to establish "Use By" dates for the drug product's. You have some stability data on the other 19 drug products, but the studies for those drug products were incomplete. For example, there was no stability study protocol or final report for Oxytocin 80 Units in 1000 mL Dextrose 5% Lactated Ringers (D5LR) N Bag, but there were testing data at two time points. That limited data was extrapolated to support all other Oxytocin/Diluent combination "Use By" dates.
- Observation 4
No retained reserve samples
OBSERVATION 4 Reserve drug product samples are not retained and stored under conditions consistent with product labeling. Specifically, you do not collect or store retains for any of the injectable drug products that you produce. Upon receipt of a complaint on March 14, 2013 for visible contamination in Magnesium Sulfate IV bags, you could not visibly examine, nor perform any analytical testing of retains.
- Observation 6
Inappropriate cleanroom clothing
FACILITIES AND EQUIPMENT SYSTEM OBSERVATION 6 Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform. Specifically, the gowning worn by employees entering the ISO 6 cleanroom includes an individually wrapped, non-sterile laundered smock that is approximately knee-length. The smock can be reused during an operational day by hanging it within the ISO 7 gowning room and spraying the smock with (b)(4) before re-donning.
- Observation 7
Incomplete cleaning and maintenance procedures
OBSERVATION 7 Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used, instructions for protection of clean equipment from contamination prior to use, and parameters relevant to the operation. Specifically, Pharmacy Facility Cleaning, Rev. 09/08/06 which only lists [illegible]. Additionally, there is no documentation to support that the dilution of [illegible] is adequate as a sanitization solution.
- Observation 8
No segregation for penicillin processing
OBSERVATION 8 The operations relating to the processing and packing of penicillin are not performed in facilities separate from those used for other drug products for human use. Specifically, your firm is processing Penicillin, and penicillin-type injectable drug products such as Oxacillin, in the same cleanroom with your non-penicillin products. The absence of a structurally isolated area creates the potential that accidental breakage of vials of penicillin could contaminate your other drug products. Additionally, the lack of separation creates the risk that a penicillin product could be mislabeled as a non-penicillin product. Patients allergic to Penicillin could be adversely effected (Observation 1A).
- Observation 9
Insufficient segregation for beta-lactams
OBSERVATION 9 Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Specifically, your firm is processing beta-Lactam injectable drug products such as Cefazolin and Cefepime from glass vials to IV bags and syringes in the same cleanroom with the rest of your non-Beta-Lactam drug products. The absence of a structurally isolated area creates the potential that accidental breakage of vials of Beta-Lactam drug products could contaminate your other drug products. Patients allergic to Beta-Lactam drug products could be adversely effected. Additionally, the lack of separation creates the risk that a Beta-Lactam drug product could be mislabeled as a non-Beta-Lactam drug product. A number of problems with your product and label control were noted during this inspection (Observation 1A).
- Observation 10
Inadequate procedures for receiving materials
MATERIALS SYSTEM OBSERVATION 10 Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures. Specifically, you purchase or receive from customers, sterile articles including: drug products, diluents in IV bags, syringes, and sterile processing equipment. You use these items to produce injectable drug products without assurance of sterility by either qualifying the vendor and reviewing certificates of sterility, or conducting your own quality assurance testing on those articles.
- Observation 11
Incomplete master production records
PRODUCTION SYSTEM OBSERVATION 11 Master production and control records lack complete manufacturing and control instructions and sampling and testing procedures. Specifically, A. Your firm's Master Batch Records do not include copies of the starting component label, so that individuals can verify that the correct product components are being used. In the last 24 months, approximately 20 finished injectable drug products were distributed after they were incorrectly compounded, incorrectly labeled, or incorrectly packaged (See Observation 1A). B. Your firm's Master Batch Records only require that the primary technician and the primary pharmacist sign or initial the production record. When other technicians or pharmacists assist, and/or work with part of the lot at another workstation, that information is not recorded. This does not allow for a complete review of the manufacturing process prior to finished product release or during any subsequent investigation. For example, environmental monitoring data cannot be completely correlated to all personnel and applicable equipment.
- Observation 12
Inadequate microbiological monitoring procedures
OBSERVATION 12 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Specifically, A. Procedure 6.02, Microbiological and Environmental Testing/Alert and Action Thresholds and Retest Requirements, does not require immediate corrective actions for action limit excursions. The area or employee is retested an additional [illegible] and the location is only taken out of service if it fails the retest. There have been at least 55 action reports since 2011, finding bacteria and mold from monitoring of personnel gloves and gowns, and viable air samples. Examples include: 1. Bacillus pumilus and Paecilomyces spp. (mold) from an employee glove, sampled on 05/24/11 (action level is 1 or more colony forming units), result was 3 cfu; retested again on 05/31/11 with no additional action taken. 2. Staphylococcus hominis and Phialophora spp. (mold) from viable air sample collected at Laminar AirFlow Workbench 10 (ISO 5) on 12/29/11 (action level is 1 cfu per m3), result was 6 cfu per m3; retested again on 01/05/2012 with no additional action taken. 3. Bacillus cereus, Brevibacillus laterosporus, and Aspergillus spp. (mold) from an employee's gloves and non sterile gown, respectively, on 06/20/2012 (action level is 1 or more and 1 or more, respectively); results were 6 and 5 cfu (gloves), and 16 cfu (non-sterile gown); the employee was retested again on 06/27/12 and 06/28/12, with no additional action taken. B. Environmental monitoring testing conducted by your firm is inappropriate in that employees sanitize their gloves and non-sterile smock with (b)(4) before collecting personnel agar test plates. C. The incubation of the environmental monitoring surface contact and personnel agar test plates are incubated incorrectly. All contact plates were observed incubated with the agar side down and not inverted, thereby allowing the condensation formed during incubation to possibly interfere with microbial growth. D. Environmental monitoring is not performed on a frequent basis or during dynamic conditions. 1. Each ISO-5 workstation is not tested for contact, viable, and non-viable environmental monitoring on a frequent basis. Environmental monitoring of each workstation is performed every [illegible], at the conclusion of compoundingofthe last operational day of that week, after most compounding operations have been completed. 2. Environmental monitoring of personnel is not performed each day of production. The testing is performed every [illegible]. Additionally, Procedure 6.02, Microbiological and Environmental Testing, Implemented 07/29/2002, does not reflect current practice because it lists [illegible] surface samples to be collected instead of the three surface plates currently collected. 3. Environmental monitoring has not been performed during operations representing the maximum number of personnel to demonstrate that the ISO-6 classification of the cleanroom can be maintained.
- Observation 13
No change control and procedure approvals
OBSERVATION 13 Written procedures are not drafted, reviewed and approved by the appropriate organizational units. Specifically, your firm does not have a system in place to track or assess the impact of changes made to processes, equipment, or procedures. There is no change control system available for investigations into process deviations or failures.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- InjunctionCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002902471 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002902471. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.