ImClone Systems, LLC
33 Imclone Dr, Branchburg, New Jersey, United States
FEI 3002889358DUNS 798223376
FDA has 10 inspections on file for ImClone Systems, LLC in Branchburg, New Jersey (FEI 3002889358), from 2008 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below. Four of the six FOIA requests for this site asked FDA for the records from a later inspection, ending Jul 27, 2023, that FDA's Data Dashboard doesn't list yet.
The most recent OAI inspection ended on Aug 21, 2020. No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant is Celltrion Branchburg, LLC (D-U-N-S 798223376).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 10, 2008–2022
- 2 OAI · 2 VAI · 6 NAI
- Inspections with 483 observations shown
- 3 of 10
- Requested under FOIA
- 6 requests, latest Aug 14, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to control drug disposition
There is a failure to control the disposition and availability of drug substances determined to be within the scope of deviation investigations before the satisfactory completion of evaluation by the quality unit. Specifically: 1. The disposition and availability of drug substance lots manufactured in your Branchburg, NJ facility and implicated in Deviation Investigation TR#thH5>.Cbl(7)<ci, initiated on 06/25/2022, for unknown debris observed in the building~b)(4) production CIP(b) (4) b 4 Tank T-4992 were not adequately controlled pending satisfactory completion of evaluation by the quality unit and closure of the investigation on 07/25/2022. Deviation Investigation TR# HG),(6)(7J(C) initially listed numerous drug substance lots within the scope of the investigation including but not limited to: Material Number1(6) (4) , Dulaglutide Drug Substance, Batch:·(o) (4) Material Number: (b) (4) Galcanezumab Drug Substance, Batch: (b) (4) aterial Number: (b (4) 41 Ramuc)rumab(bJC drug substance, Batch (b) (4) ; and Material Number: (6) (4) , Cetuximab drug substance, Batch:(b) (4) You removed all drug substance batch references from the Deviation Record '·(b) (4) (b) (4) ' on 06/30/2022 before having approval of the ''Initial Product Quality Impact Assessment" (approved on 07/01/2022). 2. You did not include all implicated drug substance lots for assessment in the TR#!b)(G).Cbl(7)(CJ Deviation Record ' b (4) ' when the !bH l was populated on 06/28-29/2022. For example: Material Number: (b) (4) Dulaglutide (6) (4) Drug Substance, Batch:.(b) (4) , Manufactured: 03/30/2022 was omitted from the ' b) (4 ' 3. The Deviation Record for investigation TR#b){G).(b)(J)(C), closed on 07/25/2022, does not include all implicated drug substance material numbers and material descriptions in the 'i.:..(5.....:)~(:4-..:..)~ ________. Review of your production history revealed that implicated drug substances: Material Number: (D) (4) Olaratumab (JMC-3G3) Drug Substance Process11>H•1 Material Number:(b) (4) Olaratumab (IMC-3G3) Drug Substance Process H~ Material Number(b) 4) , Ramucirumab ><; and Material Number: b) (4) , Necitumumab Drug ubstance Process11>1 were omitted from the "i.:..(5.....:)~(:4-..:..)~ ________."
- Observation 2
Inadequate laboratory deviation investigation
There is a failure to adequately document, explain, and investigate all deviations from established laboratory procedures. Specifically: You did not document an investigation to determine the impact, root cause, and appropriate corrective and preventive actions when an Analyst in the (b) (4) Quality Control Laboratories failed to follow procedure QCA OP-0019, Qualification and Maintenance of (b) (4) HPLC Systems to remove the column from the HPLC system before starting system flow during cleaning. Review of the LIMS column usage log for column 03_SEC_1492_0010 revealed that the column was discarded after being exposed to a cleaning cycle in HPLC Equipment TD# HPL 11•i using (b) (4) and (b) (4) on 12/14/2021.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate deviations thoroughly
QUALITY SYSTEM OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Incidents that occur during GMP activities that may have impact on the quality of products are classified as either "Observation" or "Deviation" in the (b)(4) system (SOP# QAS-NC-0001). While an "Observation" does not require investigation, a "Deviation" requires investigation to find the root cause and potential corrective actions are taken. Below are instances where the firm failed to conduct a detailed investigation when serious GMP violations occurred in the production area. Instead, the firm recorded these occurrences as an "Observation" and closed the incident without documenting all the investigation details, the root causes surrounding the issue and implementing CAPAs. In other instances, we observed that the firm's "Deviation" investigations are deficient in finding root causes that are supported by scientifically sound evidence. For example, A. TR# [illegible]: An "Observation" titled, '(b)(4) Batch Discarded' in (b)(4) was opened on 5/27/2020 and closed on 5/28/2020. This Observation documented very limited information and did not provide any investigative details. However, upon further inquiry during this inspection, the firm's Vice President, Manufacturing stated that the firm conducted an investigation and identified potential data (b)(4) [illegible]. However, no such details were provided in the closed (b)(4) document. He also stated that the personnel involved in these GMP violations are no longer employed with the firm due to the firm's investigative findings and the severity of the issue. This (b)(4) record was not elevated as a 'Deviation' despite the firm's Deviation Management procedure, QAS-NC-0001, requiring classification as "Deviation" when there is a departure from quality standards like "controls in place to protect or assure product quality" and "GMP compliance requirements". The firm's rationale for not opening a Deviation investigation is documented in this (b)(4) Observation report as 'This was an isolated occurrence'. However, we found similar incidents, where incorrect materials or material lots were used by operators, second person verified and signed, and have been reported as an "Observation" and closed without further investigation: 1. TR# [illegible]: This Observation record was opened approximately four months earlier on 1/20/2020 and closed on 1/21/2020 (Observation Title: '(b)(4) batch discarded'). 2. TR# [illegible]: This Observation record was opened approximately four months earlier on 1/24/2020 and closed on the same day (Observation Title: '(b)(4)'). 3. TR# [illegible]: This Observation record was opened on 5/8/2020 and closed on 6/17/2020 (Observation Title: '(b)(4)'). It cannot be determined from the (b)(4) Observation write-up for the four TR#s mentioned above who the Operators are and if any corrective and preventive actions were put in place. (b)(4) are used during critical purification steps of drug substances for (b)(4) and (b)(4) of the columns and for formulation of drug substances. B. TR# [illegible]: A Deviation titled, 'Atypical result (unexpected peaks) in (b)(4) profile for Galcanezumab Drug Substance' in (b)(4) was opened on 2/19/2019 and closed on 10/21/2019. On 2/13/2019, Galcanezumab drug substance, (LOT# 0039975, Run# R2Y18R0551) showed an unexpected increased peak area in the electropherogram when tested for (b)(4) by (b)(4) Non-reduced method QCA-GN-0049 (b)(4). The analyst, without conducting an investigation, retested using a different sample on 2/28/2019 (b)(4) and invalidated the original result and the new data was released in LIMS. The product was released on 3/18/2019. However, on 3/25/2019, after identifying the missing root cause investigation, the firm added a hypothesis study with a rationale, '(b)
Shortened here; the PDF has the full text.
- Observation 2
Inadequate laboratory control procedures
LABORATORY CONTROL SYSTEM OBSERVATION 2 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug substances conform to appropriate standards of identity, strength, quality and purity. Specifically, The (b)(4) obtained for purity method by (b)(4) are not consistently (b)(4), cannot be reproduced, and remain uncontrolled. The Quality Control Laboratory analysts routinely perform (b)(4) to process their (b)(4) methods for three commercial products, Galcanezumab, Necitumumab, and Ramucirumab. The (b)(4) techniques are used to (b)(4) and/or (b)(4) at the analyst's discretion. However, there is no description of the requirements and conditions under which (b)(4) can be performed using (b)(4) consistency. Furthermore, the firm does not require analysts to justify the need to perform (b)(4). The current practice is to apply the (b)(4) and use (b)(4). For example, the purity method (b)(4) for Galcanezumab, "Determination of Purity of (b)(4)", showed that the analyst reported (b)(4) peaks and utilized (b)(4) for the Sample, and reported (b)(4) peaks and utilized (b)(4) for the Reference Standard ((b)(4) total Reference Standard injections). Every injection with the exception of the blank in the sequence run contained (b)(4) to (b)(4) peaks. However, review of (b)(4) indicated no justification for the (b)(4) of (b)(4) to (b)(4) out of a total of (b)(4) peaks. In addition, different (b)(4) are performed for each injection, yet the sequence run shows one processing method.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate computer system controls
OBSERVATION 1 Appropriate controls are not exercised over computers or related production systems. Specifically, electronic data obtained from appropriately controlled. For example, A. We observed from the audit trails of the (b) (4) units as Calibration Study, Qualification Study and Verification Study have been deleted. (b) (4) units are used for the equipment qualifications, involving processes. The deleted incidents and related audit trail were not reviewed by the quality example, the following are some of the actions observed in the audit trail obtained from (b) (4) units. (b) (4) Unit Date/Time - 31-Jan-2018 at 15:57:48 01-Feb-2018 at 09:22:17 05-Feb-2018 at 14:15:14 05-Feb-2018 at 14:17:03 05-Feb-2018 at 14:17:19 05-Feb-2018 at 14:17:38 05-Feb-2018 at 14:18:05 05-Feb-2018 at 14:20:22 22-Feb-2018 at 07:06:39 23-Mar-2018 at 09:01:04 13-Apr-2018 at 09:57:49 16-Aug-2018 at 13:49:53 B. Review of the (b) (4) unit's (Serial No) had logged into the system on multiple occasions to do Audit Trail operations followed adjusting the system clock. For example, the following table shows three sequential actions recorded in the audit trail: (b) (4) Date/time - 28-Sep-2018 at 10:50:13 28-Sep-2018 at 11:03:47 28-Sep-2018 at 10:48:59 Similar actions were observed in (b) (4) units. The firm's quality unit did not review the audit trails from these were assigned administrative privileges. prevent the deletion of electronic data stored in these systems, which basis. C. We observed that test runs have been aborted from tests were not logged in the user logs, documented or reviewed. For example, review Test Instruments (ID: (b) (4)) history on the (b) (4) message "Test aborted by the operator" on multiple occasions. However, these events were not documented in the user logs and reviewed by the quality unit. the operators had aborted the runs. These and (b) (4) testing of (b) (4) processes of biological drug substances such as Cetuximab, Ramucirumab, Necitumumab and Galcanezumab, which are utilized in the production of drug products that are distributed in the U.S. market.
- Observation 2
QC laboratory data unsecured
OBSERVATION 2 Appropriate controls are not exercised over computers or related systems. Specifically, Quality Control (QC) laboratory data stored on systems are not secured from modification or deletion. QC personnel could delete an entire folder found within the firm's shared drive where stand-alone QC laboratory equipment computer systems are stored. For example, an employee demonstrated that they could create a test folder on the system attached to the UV spectrometer (Software: (b) (4)). Systems not secured include, Plate Reader (Software: (b) (4)), (Software: (b) (4)), qPCR (Software: (b) (4)) and FTIR (Software: (b) (4)). These laboratory instruments are routinely used for testing of drug substances such as Cetuximab, Ramucirumab, Necitumumab and Galcanezumab, which are utilized in the production of drug products that are distributed in the U.S. market. *DATES OF INSPECTION 11/12/2019 (Tue), 11/13/2019 (Wed), 11/14/2019 (Thu), 11/15/2019 (Fri), 11/18/2019 (Mon), 11/19/2019 (Tue), 11/20/2019 (Wed), 11/21/2019 (Thu), 11/25/2019 (Mon) and 11/26/2019 (Tue).
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Six requests to FDA under the Freedom of Information Act named this site, most recently on Aug 14, 2026.
Inspection ending Jul 27, 2023
4 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its EIR on Aug 28, 2026. FDAgent holds no copy that FDA posted.
- Aug 14, 2026FDA-FOIA-2026-7884EIRRecords released
- Apr 16, 2026FDA-FOIA-2026-3864EIRNot a Proper FOIA Request
- Jan 22, 2024FDA-FOIA-2024-685Form 483 + EIRClosed
- Oct 5, 2023FDA-FOIA-2023-8690Form 483Closed
Inspection ending Nov 26, 2019OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Aug 25, 2021FDA-FOIA-2021-5585Form 483Closed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- May 11, 2022FDA-FOIA-2022-3389Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Celltrion Branchburg, LLCD-U-N-S 798223376
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002889358 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002889358. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.