Skip to content

Yuki Gosei Kogyo Co., Ltd.

Ochiai, Jobannishigo-Machi, Iwaki, Japan

FEI 3002808534DUNS 706298080

FDA has 7 inspections on file for Yuki Gosei Kogyo Co., Ltd. in Iwaki, Japan (FEI 3002808534), from 2010 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Two of the six FOIA requests for this site have asked FDA for this inspection's records.

The most recent OAI inspection ended on Nov 17, 2017. FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant is Yuki Gosei Kogyo Co., Ltd. (D-U-N-S 690549464).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2010–2026
2 OAI · 4 VAI · 1 NAI
Inspections with 483 observations shown
2 of 7
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
6 requests, latest Oct 19, 2026
Warning letters
· CDER ↗
2 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Complaint investigations deficient and untimely

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your complaint investigations were deficient. For example, A. Complaint Investigation 2024-39 was initiated on 10/31/2024 when your customer informed of an (b)(6) incident involving anaphylactic reaction followed by death of (b)(4) (b)(6) after using [illegible] drug products. Though this non-sterile drug was manufactured using API supplied by your firm (Lot# (b)(4)), the investigation did not extend to raw materials used in the manufacturing process including (b)(4) water for potential endotoxin contamination. No retain samples were tested and no risk assessment was performed to the current testing frequency of (b)(4) water used in the production. This (b)(4) API is used in (b)(4) drug. Similar complaint was filed again on 2/19/2025 (Complaint# 2025-05) for another batch (Lot# (b)(4)) for the (b)(4) (b)(4) and the investigation is still open after nearly a year. Though these lots were shipped to Europe, the same equipment and manufacturing process is applied for the API batches manufactured for the US market. B. Complaint investigations were not completed in a timely manner by creating an investigation report and closing the investigation. The investigations were found to be open beyond the allowed time of (b)(4) for generating the report as described in the written procedure, JHA438, Quality Information Processing Procedure, version 9, section 7. Examples of open investigations include but are not limited to the following: Date Opened (YYYY/MM/DD) Complaint # Lot # API Name Days Open (b)(4) 2023/02/08 2023-04 1093 2023/03/29 2023-08 1044 2023/06/09 2023-10 972 2023/06/09 2023-11 952 2023/11/02 2023-18 826 2023/11/16 2023-20 812 2023/12/26 2023-23 772 (b)(4) 2024/03/22 2024-17 685 2024/05/10 2024-22 636 2024/08/09 2024-31 545 2024/09/12 2024-33 511 2025/02/19 2025-05 351

    2. Observation 2

      Objectionable organisms procedure ineffective

      Procedures designed to prevent objectionable microorganisms in drug substance not required to be sterile are not effective. Specifically, You have not established a written procedure for testing of objectionable organisms in (b)(4) water that is used in the production process of APIs that are used for the manufacturing of (b)(4) drug products. For example, (b)(4) API is used in (b)(4) drug products.

    Show observation 3
    1. Observation 3

      Supplier qualification onsite audit deficient

      Your supplier qualifications are deficient. Specifically, US marketed API, namely, (b)(4) uses the key starting material (b)(4). Your written procedure, SOP# JHA440, Supplier Control Procedure, dated 5/1/2025, section 3.5, requires onsite audit of main raw material supplier's site (b)(4). However, you have not conducted any onsite audit of this supplier after 3/2/2023. Also, no justification is documented to extend the onsite audit time beyond (b)(4).

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Laboratory control procedures not followed

      OBSERVATION 1 Laboratory control procedures are not followed. Specifically, during my review of your firm’s Quality Control Laboratory electronic chromatography data, deviations from the firm's written laboratory control procedures were identified. The original injections and/or processed injections are not reported, and no investigation is initiated as required per SOP JHA405, titled “The Procedure for Deviation”, effective date 09/15/17 and SOP JHA419, titled “The Procedure for Out of Specification”, effective date 09/11/15. Additionally, trial sample analyses are performed prior to the start of the reported sample analysis. The results of these trial sample analyses are not reported in official QC analytical batch records. 1. HPLC A. Raw Material Lot No.” used in manufacture of domestic (Japan) API, testing for related substance and impurities. ~The original analysis was performed on 06/07/17 starting at 11:55 am on HPLC LC030. The result was not reported in the official analytical batch record and no deviation, investigation, or OOS was initiated. ~The official/reported analysis was initiated on 06/07/17 starting at 16:59 (4:59 pm) on LC023. B. API, Lot No. | testing for related substance. ~The original analysis was performed on 07/28/15 starting at 13:45 (1:45 pm) on HPLC LC027. The result was not reported and no deviation, investigation, or OOS was initiated. -A sequence with approximately (s) injections of Lot No. ®® was performed on 07/28/15, starting at 16:18 (4:18 pm) on HPLC LC027. The results were not reported and no deviation, investigation, or OOS was initiated. ~The official/reported analysis was initiated on 07/28/15 starting at [illegible] on HPLC LC029. -Another analysis was performed the next day on 07/29/17 starting at 13:52 (1:52 pm) LC027. The results were not reported and no deviation, investigation, or OOS was initiated. cP Lot No.” testing or related substance ®® manufactured by your firm, used in industrial and in food additives per your QC Manager. -An unreported same trial injection for “Lot No. ®“ 'Sample Solution’ was performed on 11/10/14 starting at [illegible] on HPLC LC027. The result was not reported. -An unreported sample trial injection with sample name as “Blank” was performed on 11/11/14 starting at 11:30 am. This result was not reported. -Original analysis for Lot No.” Lot No.” and Lot No,” was performed on 11/11/14 starting at [illegible]. These results were not reported. -An unreported sample trial injection with sample name as “Blank” was performed on 11/12/14 starting at 11:23 am. This result was not reported. -An unreported sample trial injection with sample name as “Blank” was performed on 11/12/14 starting at 14:17 (2:17 pm). This result was not reported. -An unreported sample trial injection with sample name as “Blank” was performed on 11/12/14 starting at 14:34 (2:34 pm). This result was not reported. The official/reported analysis was initiated on 11/13/14 starting at [illegible] on HPLC 027.

    2. Observation 2

      Records not readily available for inspection

      OBSERVATION 2 Records associated with drug substance production and within the retention period for such records, were not made readily available for authorized inspection. Specifically, on 11/13/17 during my walk-through inspection of your firm's Administrative/Quality Assurance Unit building, I randomly selected different rooms and different QA personnel desks to observe and review records, starting around 1:15 pm. Later in the afternoon, during my walk-through inspection of your firm's QC building on 11/13/17, upon entering the second floor QC test room #1, around 2:20 pm I observed through the glass portion of the door several analysts moving in quick manner, with one analyst specifically near a window. This analyst appeared to close the window and with the other analysts quickly separated from one another, all of which was observed through the glass portion of the door before I entered the room. Upon entering the room, I questioned the analyst near the window and he stated that the window was opened prior to my arrival due to a foul odor, which he was closing when I observed him. After approximately 40 minutes on the second floor, and reviewing contents of randomly selected analyst desks in the QC office which is next to QC test room #1 with its own entrance and exit, I proceeded to QC first floor near the meeting/break room to get drinking water. When I asked if we could sit inside the meeting/break room, firm personnel opened the door, at which point I noticed 2 other firm personnel inside with records in front of them. As I took a seat, I noted the presence of approximately 4 plastic bags, with approximate 8-12 inches high documents in each bag and approximately 5 bins full of approximately 55 reagents and test batch samples scattered on the floor and chairs within your firm’s QC building meeting/break room. For the next approximate 4 hours, I interviewed and went through each document with at least analysts. Per the analysts, their desks were “not organized and messy” and they did not want me, the FDA investigator, to see this. In all, I spent approximately 7 hours of inspectional time with respect to this incidence. The contents of documents and items identified within the room are described in Observation 1, Observation 4, and Observation 5. In addition, on 11/14/17 and 11/16/17, during my review of HPLC raw data for approximately 11 hours of inspectional time, and my subsequent interviews with analysts responsible for performing the tests, I encountered significant time delays in receiving analytical batch records with all accompanying relevant records and due to asking the same question many different ways due to incomplete answers by analysts.

    Show observations 3 to 9
    1. Observation 3

      Deficient oversight of lab electronic systems

      OBSERVATION 3 Supervisory oversight over the laboratory electronic systems and data is deficient. Specifically, The current versions of HPLC and GC systems used by your firm for testing are Open LAB CDS Chemstation Edition A01.04 network software system and more than 7 standalone HPLC and GC systems. 1. There is no data integrity program in place to include a statistically sound representative review of all electronic data (network and standalone) by the Quality Unit to ensure completeness, consistency, and accuracy of all chromatographic raw data generated by the Quality Control (QC) laboratory. In addition, your firm's QC electronic review procedure for analytical test data worksheets associated with final API was recently implemented approximately 1 month prior to the start of this inspection. Finally, your firm has not performed a statistically sound representative review of retrospective electronic data. During the current inspection, deviations from your normal laboratory procedures with respect to data integrity were observed. 2. Administrator role for computer systems, which includes your firm's computer laboratory electronic system, is assigned to your firm's QA Manager, as of one month ago. Under the QA Manager, there are ®®® System Managers who belong to the QC Unit. During the inspection, on 11/16/17, I observed a System Manager from the QC Unit instructing your system administrator during my request for a demonstration of how users are created and deleted. This administrator has the authority to create and delete names, conducts data backup activities, delete data, and access to raw data for Open LAB CDS Chemstation and other testing programs, and as such, should be independent of the QC Unit. Additionally, on 11/13/17, I observed a QC Analyst transfer raw data from the Network Server to the C Drive of the LC30 equipment, where it was available to view on the LC30 Open LAB interface. 3. During the inspection of your QC Test Room #1 on the second floor of the QC building, where multiple electronic balance scales are located, I observed several Shimadzu and Sartorius electronic scales with functional printers. It was discovered that the password function for date/time was not locked and restricted from QC personnel. Printouts from these electronic scales are used as original records to document weighing of materials and samples and are attached to analytical batch records. Per your firm, 12 out of @ electronic scales do not have a password function option for date/time to be locked.

    2. Observation 4

      Inadequate control of expired reagents/samples

      OBSERVATION 4 The Quality Unit lacks adequate control of expired laboratory reagents, samples to be tested and finished batches. Specifically, during the inspection, on 11/13/17, I noted the presence of approximately: 25 uncontrolled expired reagents to be discarded, 11 unopened reagents and 17 samples with respect to manufacturing operations to be tested, located in your firm's meeting/break room in the QC building. Additionally, on 11/15/17, during my walk-through of the plant, I observed two unidentified (no labels) drums located on the top shelf, in an approximate ®® square foot shed with a rollup tarp. Firm personnel were not able to bring down these drums due to their weight, however, the very next day on 11/16/17, your firm identified these two drums as containing (®) lots of ®® manufactured on or around May 2013 and February 2014 for validation of product composition.

    3. Observation 5

      Inadequate GMP document controls

      OBSERVATION 5 The Quality Unit lacks adequate controls of GMP documents. Specifically, during the inspection, I noted the presence of uncontrolled records for a number of cGMP records purported to be controlled under your document control program outlined in SOP JHA408, titled “YGMP Document Control”, effective date 03/10/2017, among other procedures. A summary of documents/records identified in the QC building, meeting/break room area during the inspection is as follows: 1. On the Job training records with worksheets and chromatograms and documentation of training records belonging to at least (s) analysts. 2. Recently completed analytical testing batch records that were being “double checked” by a second analyst. 3. Blank laboratory analytical batch records for items such as reagent preparation activities. 4. Loose unidentified analytical scale printouts for Lot No.” po No, 7 Lot No. and Lot No. testing for residual solvent via GC, for drug substance manufactured for domestic (Japan) market. These printouts were not reported in official analytical batch records because the samples were retested, with no deviation or explanation as to why at the time.

    4. Observation 6

      Inadequate document control of lab records

      OBSERVATION 6 Document control of laboratory testing records by the Quality Unit is inadequate. Specifically, The Quality Assurance Unit lacks adequate control over the issuance of laboratory batch records and QA related records purported to be controlled under the following procedures: SOP JHA424, titled “Manufacturing Operation Procedure”, effective date 11/1/17; SOP JHA420, titled “YGMP Document and Record Generation Procedure”, effective date 11/01/17; and SOP JHA508, titled “Analytical Testing Execution Procedure”, effective date 11/01/17. The QA unit lacks adequate control over the issuance of laboratory analytical testing worksheets, in that during the inspection it was observed that analytical batch records for API manufactured by the firm are issued by QC personnel, who have direct interest in all raw data generated during testing. Additionally, uncontrolled laboratory batch records/worksheets, chromatograms, and weight scale printouts were observed during the walk-through of the inspection on 11/13/17 with several different analysts.

    5. Observation 7

      Inadequate equipment design/qualification

      OBSERVATION 7 Equipment used in the manufacture or holding of drug components is not of appropriate design to facilitate operations for its intended use and maintenance. During the walk-through of your firm's manufacturing plant I observed an approximate [illegible] cubic meters ( [illegible] Liters) tank used for holding of solution process. Your firm explained that there was a leak in the original tank, ID # T-503, on or around 08/23/17. On or around 08/23/17 your firm moved a temporary intermediate holding tank to the Plant in order to resume production operations. As of the start of the current inspection, your firm has not performed Installation Qualification, Operational Qualification, and Performance Qualification for this temporary intermediate holding tank. Since installation of this temporary holding tank, your firm has manufactured approximately [illegible] lots of ®® which could be sold as API.

    6. Observation 8

      No unique lot codes for received components

      OBSERVATION 8 Each lot in shipment received was not identified with a distinctive code for each container or grouping of containers for components. Specifically, Your firm does not assign a unique lot number for each lot in shipment received for all components used in the manufacture of drug substances. Currently, your firm uses the lot number assigned on the component manufacturers Certificate of Analysis. In addition, there are no adequate procedures for assigning unique lot numbers for drug components received.

    7. Observation 9

      Equipment not appropriately identified

      OBSERVATION 9 Equipment used during laboratory operations and production of an intermediate or API are not appropriately identified. Specifically, 1. An empty functional refrigerator located in QC instrument room on the first floor with no status. Per your firm’s QC Manager, this refrigerator is for backup purposes, in case another refrigerator is not functional. 2. Temporary Intermediate holding tank, located in the Plant in order to resume production operations after original tank was found to have a leak on or around 08/23/17. This is a repeat observation from the last USFDA inspection, dated 09/2016.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on Oct 19, 2026.

  • Inspection ending Feb 6, 2026VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Oct 19, 2026FDA-FOIA-2026-10129EIROpen
    2. Oct 18, 2026FDA-FOIA-2026-10126EIROpen
  • Inspection ending Jul 28, 2021VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. May 25, 2022FDA-FOIA-2022-3875EIRClosed
  • Inspection date not given

    3 requests. FDA released records in answer to a request for its Form 483 on Apr 6, 2026. FDAgent holds no copy that FDA posted.

    1. Jun 29, 2026FDA-FOIA-2026-6197Inspection records· 1 of 3 sitesRecords released
    2. Apr 9, 2026FDA-FOIA-2026-3507Form 483· 1 of 3 sitesRecords released
    3. Mar 27, 2026FDA-FOIA-2026-3012Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record
  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2026
Registrant
Yuki Gosei Kogyo Co., Ltd.D-U-N-S 690549464

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002808534 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002808534. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.