Wockhardt, Ltd.

Sf-12 Shrinathji Arcade Plot 138, Bulk Drug Division; Karmatur Road, Ankleshwar, India

FEI 3002808500

FDA has 2 inspections on file for Wockhardt, Ltd. in Ankleshwar, India (FEI 3002808500), from 2012 to 2015. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

3 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2012–2015
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Import refusals
3 refusals
Import alerts
66-40Red List
Matched on FDA’s firm name and street address

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Recordkeeping and document destruction oversight

      Record entries documenting your operations shall be made contemporaneously and permanently in spaces provided for such entries, and should identify the person making the entry. Corrections to entries shall be dated and signed and leave the original entry still legible and preserved. Specifically, A) I did not observe Quality Unit oversight/approvals required for the destruction and incineration of documents. For example on December 7, 2015, the following records were discovered torn/shredded in the scrap yard area awaiting incineration: Bo ©@ © i. Raw Material label for batch dated October 30, 2015 ii. Maintenance Work Order Permit for repairing leakage from®®) gasket of] ©) located in area dated November 2, 2015 iii. Engineering Contractor Hot Work Permit for dismantling and cutting unwanted line for reactors removed from production building®® area dated October 7, 2015 B) On December 7, 2015 during a walk-through of the Process Development Laboratory, an uncontrolled private/personal diary was discovered containing experimental protocol laboratory data. The Process Development Laboratory is used to conduct experimental quality failure investigation sample preparations, route of synthesis, and scale-up process related laboratory testing. Entries in the uncontrolled private/personal diary included calculations, molecular weights and experimental details and data.

    2. Observation 2

      Aseptic processing and gowning issues

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, A) Aseptic Media Fill “Report for Aseptic Process Simulation by Piggyback Media Fill Method of Sterile Plant 6)@) vPOY@TAPV/R-6 effective October 15, 2015 explains that the media fill sterility testing for the Aseptic processing area was performed using (0) 4) finished sterile API containers filled during the media fill. The remaining) 4) finished sterile API filled containers were sampled but not tested for sterility and were retained for failure investigation purpose only. B) You did not identify worst-case locations on equipment and processing areas for microbial environmental swabs and microbial contact plates inside the sterile production area in building® ® that is used to manufacture Sterile®® USP and Sterile ©) Active Pharmaceutical Ingredients. C) On December 10, 2015 during a walk-through of the sterile manufacturing block®@ I observed that three (3) out of ten (10) sterile gowns, which had been quality checked for acceptance in the sterile area had unraveled stitching threads extending from the hood, zipper and pants on the gown. The thread fiber lengths were between 1em and 3em. One (1) of the three (3) sterile gowns had shredded boot strap ties with thread fiber lengths in excess of 10cm. Sterile manufacturing block® ® 5 used for the manufacturing of Sterile ® USP and Sterile®® Active Pharmaceutical Ingredients. D) For thd®®" Facility environmental monitoring, I did not observe any traceability when the®®) environmental isolates were recovered from the production area. Furthermore, for up to®® all of the b) 4) microbial culture(®) (4) created from the(®@) microorganisms were being stored in the same bag together corresponding to the®@ of ye. E) I observed operator interventions including hand movements interfering with the unidirectional flow of smoke for aseptic connections of(6) 4) between the (0) 4) and (0) (4) of(b) (4) performed inside the Laminar Air Flow LAF-712. These operator interventions were observed during review of the unidirectional airflow smoke study simulation “Report for Unidirectional Air Flow Visualization in Dynamic Condition” VP®) 4) /GRADE A Air Flow Visualization/R2 dated October 12, 2015.

    Show observations 3 to 8
    1. Observation 3

      Computer system access and data deletion

      Computerized systems shall have sufficient controls to prevent unauthorized access or changes to data. Specifically, A) Prior to July 25, 2014, Quality Control Analysts had the ability to delete raw data files from Gas Chromatograph instrument ID QA/G07 used in the ® @ manufacturing facility for testing residual solvents for finished APIs and Raw Materials. B) The following Gas Chromatograph injections were performed but the firm did not maintain any supporting documentation why these injections occurred. i. On January 26, 2013, three (3) injections of Raw Material ®® ‘anker truck Batch® ®) and solvent tank FNR10062 samples were performed corresponding to injection file EJAN13G07\DATA\®®) 2601 ®@701.0:2@ 02.0 and®@ 03.0 101.D; 102. 3.D. Gas Chromatography Injection file EA\JAN| 3G07DATAD d 2601 @@ 01.D as performed on January 26, 2013 at®® 1d corresponds to Raw Material ®# 5 ianker truck Batch with a passing result purity of ®@@ (Specification NLT®) /0) Gas Chromatography Injection file EJANI3GOT\DATA®@ 26010 "03.0 was performed on January 26, 2013 a{® and corresponds to Raw Material ®@ solvent tank Batch® with a failing result purity of @® 4 (Specification NLT) /0) Gas Chromatography Injection file EJANI3GOT\DATA® D7 2601 ®@" 02D was performed on January 26, 2013 a®@ and corresponds to Raw Material® © solvent tank Batch ® with a passing result purity of ®@ (Specification NLT) Yo) However, only injection (PV) 02.D) was officially reported for Raw Material © solvent tank Batch ED without any documentation explaining why the failing injection result for (© @ 03.D) was excluded from the analysis. ii. On January 21, 2013 a single injection of a sample labeled as Residual Solvent®® injection file: D:\JAN13GO7\DATA\DEFAULTB.D was performed. [LED Residual Solvent®@ was previously analyzed and released in December 2009. However, this single injection performed on January 21, 2013 was not reported. On January 21, 2013 an in-process batch [PIE sample 1 for Residual Solvent ©) under injection file: D:\JAN13GO7\DATA®® 21010® 5004 D was performed and reported. On January 21, 2013 an in-process batch sample 2 for Residual Solvent ©) under injection file: D:\JAN 13GOT\DATA®@ 1101 5005.D was performed and reported. iii. On May 8, 2014, three (3) injections of OYE) Batch ®® in-process residual solvent samples were performed corresponding to injection file C\DATA\MAY_2014_GO6\DATA\SE. [Rey 0805\ste®@) 10805_008.rst; 009; and _010. However, only two (_008.rst and _009.rst) out of these three injections (_008.rst; _009.rst; and 010) were officially reported without any documentation explaining why the injection (_010) was excluded from the analysis. iv. On May 7, 2013 Residual Solvent Analysis for injection was initiated under sample set file: C\DATA\WOCKHARDT\WMAY 2013_G06\DATA\® @ 'C_0705 for sample name PD [LED A and PD_B. There is no corresponding documentation or Process Development Experimental Protocol/Report describing the purpose of these injection samples.

    2. Observation 4

      Unvalidated laboratory computer systems

      Computerized systems shall be validated and the depth and scope of the validation depends on the diversity, complexity, and criticality of the computerized application. In addition, appropriate installation and operational qualifications shall also demonstrate the suitability of computer hardware and software to perform assigned tasks. Specifically, The following twelve (12) computerized system and instrument software used in the quality testing laboratory that are currently in use for routine testing have not been validated: Instrument Name Software Date of Installation in Laboratory FTNIR Omnic 9.2.86 June 18, 2015 Stability Chambers Newtronic IC DAS 1.2 May 29, 2015 TOC-L TOC Control L 1.02 July 25, 2015 LBPC Pharm Spec Ver. 3 June 25, 2015 Polarimeter Spectra Manager 2.10.01 July 8, 2015 Perkin UV UV Win LabES 6.0.4 July 21, 2015 TOC-V TOC-V 2.10 July 27, 2015 FTIR Omnic 9.3.32 August 4, 2015 Perkin UV UV Win Lab ES 6.0.4 July 23, 2015 FTIR Shimadzu IR Solution 1.30 September 4, 2015 Malvern Malvern Master Sizer 5.61 August 7, 2015 TLC WinCats 1.4.9.2001 September 10, 2015

    3. Observation 5

      Change control not initiated for changes

      Proposals for GMP relevant changes shall be drafted, reviewed, and approved by the appropriate organizational units and reviewed and approved by the quality unit. Specifically, A) On October 14, 2015, a change in quality testing laboratories occurred and a change control was not initiated and reviewed by the quality unit. On this date ®® JSP Finished API batches® © and ©) were sent to a different contract testing laboratory to conduct routine quality release testing of Polymorphism by X-Ray Diffraction (XRD) (MOA-300937-02-2). B) On July 28, 2015, Total Organic Carbon (TOC) instrument ID QAI/T02 computer system hard drive and instrument software was removed from the laboratory and a new hard drive and instrument software version was installed. On December 7, 2015, there was no entry in the TOC instrument ID QAI/T02 equipment logbook discussing this change in computer system hard drive and instrument software. Furthermore, change control (CC/AN-QC/15-092) associated with changing non-chromatographic laboratory computer system hard drives and instrument software versions does not discuss the quality testing laboratory instruments that are affected by this change.

    4. Observation 6

      Calibration failure not assessed for impact

      Deviations from approved standards of calibration on critical instruments shall be investigated to determine if these could have had an effect on the quality of the intermediate(s) or API(s) tested since the last successful calibration. Specifically, On January 10, 2015, the Total Organic Carbon Analyzer instrument QAI/TO3 that was used to test [RE and ®@® Water samples failed Calibration acceptance criteria for Standard Deviation value of®)@) (Specification gE and Coefficient Variation value of @@) (Specification Be). However, an assessment was not performed to evaluate if the calibration failure had any impact on the samples tested on the instrument since the previous passing calibration.

    5. Observation 7

      Analytical method (XRD) not validated

      Analytical methods shall be validated to include consideration of the characteristics included in the validation of analytical methods. The degree of analytical validation performed shall also reflect the purpose of the analysis and the stage of the API production process. Specifically, On December 8, 2015 USP Finished Active Pharmaceutical Ingredient in-house developed test method Polymorphism by X-Ray Diffraction (XRD) (MOA-300937-02-2) that is used for the identification of the finished API had not been validated

    6. Observation 8

      Facility maintenance, paint and water leaks

      Buildings and facilities used in the manufacture of intermediates and APIs should be constructed to facilitate cleaning, maintenance, and operations as appropriate to the type and stage of manufacture and to minimize possible contamination from equipment. Specifically, A) On December 9, 2015, during a walk-through of the Production Block®" finished dosage line API manufacturing facility, I observed rust, flaking and chipping paint on the) for © 4) as well as the ceiling and overhead I-beams that are located directly above the (0) 4) covers that are opened for() (4) of materials into the®® ised during the® © Stage and ® ©) AED Stage manufacturing process for ON) \PIL. B) On December 9, 2015, during a walk-through of the®@ Water Unit that supplies ® @ water to Production Block®® I observed incoming treated water leaking from the top gasket and onto the floor from the® ® ank. This®@) water generated inside the Water Unit © Us) is used in the manufacture of different finished Active Pharmaceutical Ingredients in Production Block®® ©) 4) including APL.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002808500, one row per refused product line.

3 refusals on 2017-11-09 · charged DRUG GMPS on 3 · no FDA sample analysis

FDA firm profile
  • 2017-11-09

    ANTIBIOTIC N.E.C.56YCR99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast Imports799-2643011-4/11/3

  • 2017-11-09

    ANTIBIOTIC N.E.C.56YCR99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast Imports799-2643011-4/11/2

  • 2017-11-09

    ANTIBIOTIC N.E.C.56YCR99

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southeast Imports799-2643011-4/11/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2016-08-05

    FDA’s entry
    Wockhardt, Ltd. · Sf-12 Shrinathji Arcade Plot 138, Bulk Drug Division; Karmatur Road, Ankleshwar, Gujarat INDIA
    FDA’s inspection record for FEI 3002808500
    Wockhardt, Ltd. · Sf-12 Shrinathji Arcade Plot 138, Bulk Drug Division; Karmatur Road, Ankleshwar, India

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    10 products

    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    Show 7 more products
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002808500 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002808500. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.