PLIVA Hrvatska d.o.o.
Prilaz Baruna Filipovica 25, Zagreb, Croatia
FEI 3002807904DUNS 499659316
FDA has 8 inspections on file for PLIVA Hrvatska d.o.o. in Zagreb, Croatia (FEI 3002807904), from 2012 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
4 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, sterilization and repacking, through Dec 31, 2026. Its registrant is Pliva Hrvatska d.o.o. (D-U-N-S 499659316).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2012–2023
- 0 OAI · 6 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 8
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Jun 18, 2026
- Warning letters
- None on file
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringPosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Stability not demonstrated for PSD study
These observations pertain to the particle size distribution (PSD) data that was reported in Study (b)(4) [illegible] was not demonstrated, specifically: 1. Stability of test product (b)(4) during dialysis and storage during the dialysis experiment using an analytical assay at ambient temperature for the duration of the study. Specifically: a) Stability was not demonstrated for (b)(4) during the dialysis experiment using an analytical assay at ambient temperature for the duration of the study. b) Stability of the dialyzed (b)(4) solution stored before dynamic light scattering (DLS) analysis using an analytical assay was not demonstrated under storage conditions at ambient temperature to cover the duration that samples were stored before analysis.
- Observation 2
Missing storage condition documentation post-dialysis
Documentation is not available to demonstrate the storage condition of (b)(4) post dialysis.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jun 18, 2026. It asked for a Form 483.
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Jun 23, 2026. FDAgent holds no copy that FDA posted.
- Jun 18, 2026FDA-FOIA-2026-5932Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002807904, one row per refused product line.
4 refusals from 2017-05-23 to 2020-05-14 · charged UNAPPROVED on 2, DIRECTIONS on 2 · no FDA sample analysis
FDA firm profile- 2020-05-14
AZITHROMYCIN (MACAROLIDES)56IDY76
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-7123498-0/51/1
- 2019-02-27
MISCELLANEOUS PATENT MEDICINES, ETC.66VIS99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports655-2134173-9/11/2
- 2017-06-20
CHELATING AGENT N.E.C.63JIS99
DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING
Division of Northern Border ImportsUPS-3260405-1/11/1
- 2017-05-23
METOCLOPRAMIDE (ANTACID)60SCA23
NOT LISTED 502(o), 801(a)(3); MISBRANDING
DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING
Division of Northeast ImportsJ37-0009050-2/71/1B
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, sterilization, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Pliva Hrvatska d.o.o.D-U-N-S 499659316
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002807904 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002807904. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.