Skip to content

Geneva Woods Pharmacy Inc

501 W International Airport Rd Ste 20, Anchorage, Alaska, United States

FEI 3002759569

FDA has one inspection on file for Geneva Woods Pharmacy Inc in Anchorage, Alaska (FEI 3002759569). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2019
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate containment and cleaning

      OBSERVATION 1 Beta-lactam drugs were produced without providing adequate containment, cleaning of work surfaces, utensils/equipment and personnel to prevent cross-contamination. Specifically, between 04/10/2017-04/09/2019, your pharmacy produced (o} ( ) beta-lactam drug products in your non-hazardous area on work surfaces also used for the production of non-beta lactam products. a) Your pharmacy cleans work surfaces ((b) (4 ) I) in your non-hazardous area with [( b ) (4) I l(6) (4) I - --- b) Your pharmacy does not have dedicated equipment for beta-lactam and non-beta lactam products. Production equipment is shared between both beta-lactam and non-beta lactam products. c) Equipment used to produce beta-lactam products is cleaned with [(6) (2J) I and rinsed with distilled water. Following cleaning, this equipment is used for any non-hazardous product, including a non-beta lactam product.

    2. Observation 2

      Inadequate cleaning for hazardous drugs

      OBSERVATION 2 Hazardous drugs were produced without providing adequate cleaning of utensils/equipment to prevent cross contamination. Your pharmacy produces approximately [illegible] different drug products in your hazardous room and approximately [illegible] patient-specific prescriptions per day. Specifically, between 04/12/2018 to 04/12/2019, your pharmacy produced [illegible] testosterone prescriptions from the Active Pharmaceutical Ingredient (API) testosterone and [illegible] progesterone prescriptions from the API progesterone. a) Your pharmacy does not have dedicated equipment for hazardous drugs. Production equipment is shared between the [illegible] products produced in your hazardous room. Dirty equipment (used to produce hazardous drug products) is cleaned with [(o)-(4) I and distilled water.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002759569 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002759569. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.