Skip to content

Veterinary Pharmacy Corporation

TYPE ESTAII.ISHMENT INSPECTED, Saint Peter, Minnesota, United States

FEI 3002726048

FDA has 8 inspections on file for Veterinary Pharmacy Corporation in Saint Peter, Minnesota (FEI 3002726048), from 2009 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
8, 2009–2026
0 OAI · 4 VAI · 3 NAI
Inspections with 483 observations shown
2 of 8
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
1 request, latest May 7, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetCompounding PharmacyPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Amoxicillin area contamination and damage

      Contamination was observed in your production area and areas adjacent to production areas. Specifically, A) A pallet of used compounding equipment was observed in the non-classified Amoxicillin storage room. Items on this pallet included, but were not limited to, used process (b)(4) which were coated with yellow residue, metal fittings, and hoses. All equipment on this pallet appeared to be coated with a layer of white powder. Your staff stated that this pallet of used equipment had been present in this location for approximately 1.5 to 2 years. This pallet is located immediately adjacent to the door leading to Amoxicillin Room (b)(4) where finished product compounding and packaging of Amoxicillin products takes place. B) Widespread and extensive damage was observed on the painted drywall walls in the Amoxicillin processing area. This damage included an approximately 6-inch long and 3-inch deep hole punched in a wall from the handle of an over-extended door, multiple scrapes in paint and drywall ranging from 1 to 6 inches, and broken floor ceramic molding. This damage was noted approximately 10 feet from the chute where Amoxicillin capsules were [illegible]. C) Black stains were observed on damaged wall sections where paint and drywall had been scraped off, approximately 10 feet from the chute where Amoxicillin capsules were [illegible] into the container and approximately 10 feet from the capsule grinder/powder sieve, during the grinding operation of [illegible] of Amoxicillin active ingredient capsules on 3/12/26. This lot was used in the compounding of Ultramox Amoxicillin Lot #VUAN00C 17268 on 3/17/26. D) Dark stains were noted on multiple ceiling vents in Amoxicillin Room (b)(4) above compounding equipment during the production of Ultramox Amoxicillin Lot #VUAN000C0926A on 3/9/26. E) Personnel were observed moving between the dedicated Amoxicillin compounding area and other locations inside the firm without changes of garbing on 3/9/26 and 3/10/26. Your firm does not have written procedures regarding personnel movement or garbing changes between Amoxicillin and non-Amoxicillin production areas. F) Your firm does not use a deactivating agent for cleaning Amoxicillin from equipment or packaged finished products exiting the dedicated Amoxicillin compounding area. [illegible] coated with compounded Amoxicillin powder were observed exiting the dedicated Amoxicillin compounding area carrying packaged finished product to your central warehouse and packaging area on 3/9/26 and 3/10/26 without being cleaned or wiped down with any cleaning agent prior to transport. G) Powdered Amoxicillin was observed covering all production equipment in the Amoxicillin Grinding room, Amoxicillin Storage room, and Amoxicillin Room (b)(4) during the production of Ultramox Amoxicillin Lot #VUAN000C0926A on 3/9/26. Piles of powdered excipient used in the compounding of this lot were also noted leaking from a damaged valve onto the floor of Amoxicillin Room (b)(4) at this time. H) Cobwebs were noted in the overhead scaffolding supporting production equipment in Amoxicillin Room (b)(4) during the production of Ultramox Amoxicillin Lot #VUAN000C0926A on 3/9/26. I) An approximately 3-foot-long plastic shovel was observed stored laying on the floor of Amoxicillin Room (b)(4) during the production of Ultramox Amoxicillin Lot #VUAN000C0926A on 3/9/26. J) One pallet containing: (b)(4) of Kolliphol were observed in Compounding Room (b)(4) on 3/10/26 during the compounding of Lot #VJVC 126A of Ivermectin. Your staff stated that this Kolliphol was used for R&D use only and was stored in the compounding area because of insufficient storage space in the R&D room.

    2. Observation 2

      Inadequate media fill simulations

      Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, Aseptic process simulations (media fills), along with the governing procedure SOP CR-02 - Aseptic Technique & Gloved Fingertip / Thumb Test - are deficient in that they do not simulate the finished product container size, number of units, or worst-case conditions that may arise during compounding activities. Media fills conducted by your firm [illegible] to simulate aseptic processes utilize (b)(4) which contain a total of: (b)(1) [illegible] ,JV bags and associated equipment. (b)(4) is used by each sterile compounding technician as part of their [illegible] aseptic process simulation evaluation. During a review of your sterile compounding records for March 4 2026, a lot size of [illegible] 2000 ml bags of Iron 20% (200 mg/ml) was noted in the compounding of Lot #V20030526 on 05MAR2026. This batch was compounded to fulfill Rx [illegible] and shipped to your customer on 3/11/2026. Additional batch sizes of (b)(4), an ~2000 mL bags were also noted in compounding records from 04MAR2026 - 10MAR2026. Additionally, Form CR-37 Periodic Cleanroom Aseptic Evaluation - which is used to (b)(4) qualify your sterile technicians, does not document the amount of time required to conduct the media fill using the (b)(4). Start and stop times, along with total operational durations, are also not recorded on your CR-24 - Iron Stock Bag Compounding Forms for compounding activities.

    Show observation 3
    1. Observation 3

      Failure to ensure endotoxin/pyrogen controls

      Deviation from the procedural requirements of a decree of injunction. Specifically, Consent decree number 00-CV-2725 Paragraph 17 requires you to establish, continuously maintain and/or follow procedures, processes and controls to ensure the following: Paragraph 17(A)(vi), Establish and implement Procedures to continually monitor compounded drugs products to ensure that master formula requirements described in subparagraph 17(A)(vii), are being followed. including but not limited to product strength and absence of pathogens, and, in the case products labeled as sterile; the absence of endotoxins and pyrogens; and Paragraph 17(A)(vii), Ensure that every product that Defendants label as sterile is in fact sterile, and is free of pyrogens and endotoxins. You manufacture the following sterile products: Iron 135.33mg/mL, Vitamin B Comp 1.5mg/mL Injectable - 1800ml Iron 184mg - Gent 8mg - 1500ml Iron 200mg Injectable Iron 75mg - Gent 7.5mg - B Comp - 1500mL Iron 95mg - Gent 5mg - 1500mL Iron 98.3mg - B Complex - 1500mL Iron 100 mg/mL Injectable Iron 133.3 mg - Gent 3.3 mg - Injectable - 1500mL Iron 100 mg - Gent 3.4 mg - 1500mL Inj Iron 100 mg - Gent 5 mg INJ -1500mL Iron 100 - Gent 5 - B-Complex - 1500mL Injection 10- Gent 5 - B-Complex Injection- 1500mL Bag Iron 100 - Linc Iron 173- Gent 5 - Injection- 1500mL Bag Iron 173- Gent 5 - B-Comp - 1500mL Inj Iron 186.6 - B-Complex INJ - 1500ml Bag Iron 186.6 - Gent 5 - B-Complex Injection- 1500mL Bag Iron 180.6 - Linc24 - B-Comp INJ- 1500mL Bag Iron 190 - Gent 5 - Injection - 1500mL Bag Iron 190mg-B-Comp 11.26mg - 2000mL Bag (1800mL Stock Bag) Iron 50mg/mL, Tylosin 5 mg/mL, B-Complex Injectable Iron 133.3 mg/mL, Tylosin 8 mg/mL, Gentamicin 3.3 mg/mL Injectable Iron 150 mg/mL, Tylosin 12.6 mg/mL, Gentamicin 5 mg/mL, B-Complex Injectable Iron 186.8 mg/mL, Tylosin 12.6 mg/mL Injectable Iron 100mg/mL, Tylosin 10mg/mL, B-Complex Injectable - 1500mL Iron 181.8mg-Gent 4mg-B-Comp 11.5mg - 1500mL Bag (1300mL Stock Bag) Iron 182.84mg-Gent 8mg-Super B 1.3mg (1300ml Stock Bag) Iron 75mg-Gent 7.5mg-Super B Comp (1000mL Stock Bag) Iron 95mg-Gent 5mg Inj (1250ml Stock Bag) Iron 98.3mg-Super B Injectable (1250ml Stock Bag) Iron 187.5mg/mL, Tylosin 12.5 mg/mL Injectable - 1600mL Iron 180mg-Linc 20mg - 2000mL (1800ml Stock Bag) Iron 150mg-Linc 15mg-Gent 5mg-Super B Comp (1100ml Stock Bag) Iron 150mg-Gent 4mg (1100ml Stock Bag) Iron 150mg-Gent 15mg-Super B Comp (1100ml Stock Bag) Iron 175mg-Tylosin 12.6mg-Gent 6.1mg (1300ml Stock Bag) but have not established adequate procedures/processes/controls to ensure each of these products is free of pyrogens and endotoxins in that you do not test each lot of product for pyrogens/ endotoxins. In particular, the following recent sterile compounded lots were released by your firm without endotoxin testing: V20030426 Iron 20% 2000ml 04MAR2026 V20030526 Iron 20% 2000ml 05MAR2026 V20030926 Iron 20% 2000ml 09MAR2026 V20031026 Iron 20% 2000ml 10MAR2026 V20031126 Iron 20% 2000ml 11MAR2026 Additionally, your written procedure, SOP CR-07 - Injectable Product Endotoxin Specifications - is deficient in that it states "A random sample of injectable iron dextran preparation will be sent to a qualified outside laboratory for endotoxin testing (b)(4)" instead of establishing a procedure for endotoxin testing on every lot of sterile product compounded at your firm.

  2. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  3. NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. n/a

      Procedural requirements

      Deviation from the procedural requirements of a decree of injunction.

  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on May 7, 2026. It asked for a Form 483.

  • Inspection ending Mar 19, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. May 7, 2026FDA-FOIA-2026-4686Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002726048 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002726048. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.