Skip to content

Lee & Company

4300 Grand Ave, Fort Smith, Arkansas, United States

FEI 3002596670

FDA has 3 inspections on file for Lee & Company in Fort Smith, Arkansas (FEI 3002596670), from 2009 to 2016. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

The most recent OAI inspection ended on Feb 21, 2013. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2009–2016
1 OAI · 1 VAI · 1 NAI
Inspections with 483 observations shown
1 of 3
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate environmental monitoring program

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A) Your firm's procedures for monitoring the ISO Class 5 area are not suitable to ensure the quality of air. For example, your firm conducts no monitoring for viable and non-viable particles during aseptic filling of sterile drug products. The current practice of firm personnel monitor viable [illegible] via settling and contact monitor for non-viable in static conditions. B) Your firm lacks studies under dynamic conditions to ensure the flow pattern of filtered air in the ISO Class 5 area.

    2. Observation 2

      Sterilization processes not validated

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A) Your firm has not performed any qualification studies on your [illegible]. For [illegible] you have no studies or [illegible] studies [illegible] used to sterilize vials, septums, equipment, etc. Further, the process of sterilizing suspensions have not been validated. B) Your firm has not established the process for sterilization of empty vials and septums (stoppers) intended for aseptically filling with sterile drug products. For example, there is no data to support the critical parameters of time - exposure necessary to render the materials sterile. Moreover, there is a lack of establishing the loading pattern for vials and septums in the [illegible].

    Show observations 3 to 7
    1. Observation 3

      Inadequate aseptic technique procedures

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, A) Your firm has no written procedures that establish aseptic technique of the operator while working in the aseptic areas during aseptic filling operations. For example, there are no directions for the changing of sterile gloves or the frequency of sanitization of sterile gloves during set-up and filling operations. B) Your firm's SOP #7.1, approved 2/2/10, Validation of the Aseptic Technique, provides for filling 10 ml clear vials with media and incubating. However, your firm routinely fills up to [illegible] vials during aseptic operations, and fills 2, 10, 30 and 50 ml vials, and normally uses amber colored vials. Therefore, your current media fill studies do not represent actual aseptic filling operations.

    2. Observation 4

      Missing production/process control procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, there is no assurance that your firm has adequate process controls to prevent failures of your sterile drug product. For example, the sterilization processes for suspensions and solutions have not been designed following a scientific rationale. Suspensions are sterilized in bulk prior to the aseptic filling process and solutions are filter sterilized with a sterile filter.

    3. Observation 5

      No product stability or preservative testing

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, A) Your firm has no scientific data to justify the assigned BUD (six months) at room temperature for any sterile injectable drug product, all of which contain a preservative. None of the formulations that you produce were placed on a stability program to determine an appropriate BUD period. B) [illegible] failed to [illegible] any anti-microbial effectiveness testing to determine [illegible] effectively inhibits microbial growth in your sterile [illegible]. Preservatives are used in the manufacture of all of your sterile drug products.

    4. Observation 6

      No supplier QA or independent testing

      Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals. Specifically, your firm has no program for the evaluation of suppliers test results. Further, you conduct no independent testing of any raw material prior to use in producing sterile drug products.

    5. Observation 7

      Quality control procedures not followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, SOP #9.5, approved 1/22/03, Visual Examination of Sterile Preparation, requires that injectable preparation will be inspected after filling into the sterile vial. However, your firm's current practice is to only visually inspect the bulk product while contained in an IV bag while located in the ISO Class 5 hood.

  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002596670 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002596670. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.